Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach

Arterial blood pressure is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. This study examines the relationships between arterial blood pressure and certain features of the photoplethysmographic (PPG) signals obtained from 15 young healthy subjects. Width of 1/2 pulse amplitude, width of 2/3 pulse amplitude, systolic upstroke time and diastolic time of the pulse were selected as features of the PPG signals. The experiment involved three sessions: rest, step-climbing exercise, and recovery from exercise. It was found that the diastolic time has higher correlation with systolic blood pressure (SBP) and diastolic blood pressure (DBF) than other features. The mean differences between the estimated and the measured blood pressure using a standard device are 0.21 mm Hg for SBP and 0.02 mm Hg for DBF. The corresponding standard deviations are 7.32 mm Hg for SBP and 4.39 mm Hg for DBF. The preliminary results indicate that it is possible to use the photoplethysmography only for cuffless and continuous estimation of arterial blood pressure.

[1]  C. Taylor,et al.  The covariation of blood pressure and pulse transit time in hypertensive patients. , 1981, Psychophysiology.

[2]  L A Geddes,et al.  Pulse transit time as an indicator of arterial blood pressure. , 1981, Psychophysiology.

[3]  P. Obrist,et al.  Aortic-radial pulse transit time and ECG Q-wave to radial pulse wave interval as indices of beat-by-beat blood pressure change. , 1983, Psychophysiology.

[4]  G. V. Marie,et al.  The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise. , 1984, Psychophysiology.

[5]  P. Talke,et al.  Measurement of systolic blood pressure using pulse oximetry during helicopter flight , 1991, Critical care medicine.

[6]  A Indrayan,et al.  Can pulse oximetry be used to measure systolic blood pressure? , 1992, Anesthesia and analgesia.

[7]  R. Sepponen,et al.  Non-invasive blood pressure data acquisition employing pulse transit time detection , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[9]  Kalju Meigas,et al.  Continuous blood pressure monitoring using pulse wave delay , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Mahmood Saghaei,et al.  Blood pressure measurement by pulse oxymetric method and comparison with conventional technique. , 2002, Acta anaesthesiologica Sinica.