A 64-channel wireless implantable system-on-chip for gastric electrical-wave recording

This paper presents the design and post-layout simulation results of a 64-channel wireless and implantable system-on-chip (SoC) for studying gastric electrophysiology. The SoC includes 64 time-multiplexed low-noise amplifiers (LNAs) followed by a 10-bit low-power successive approximation register (SAR) analog-to-digital converter (ADC), and a power management unit for recharging the SoC battery inductively and communicating with an external reader via load-shift keying (LSK) modulation of the receiver coil. The SoC has been designed in a 0.35 μm standard CMOS process, occupying 25 mm2. In post-layout simulations, each LNA achieved an adjustable gain of 40–52 dB, and an input-referred noise of 6 μVrms within the bandwidth of 10 mHz–2 Hz while consuming 40 nA from a single 2.5 V supply. Each channel was sampled at 244 Hz with 10 bits of resolution, leading to the net data rate of 156 kbps for recording 64 channels. The power management, operating at 13.56 MHz, recharged a 3.7 V battery with the adjustable current range of 0–15 mA while maintaining the rectifier voltage constant at 4.4 V.

[1]  Reid R. Harrison,et al.  The Design of Integrated Circuits to Observe Brain Activity , 2008, Proceedings of the IEEE.

[2]  B. Moshiree,et al.  Gastroparesis: current diagnostic challenges and management considerations. , 2009, World journal of gastroenterology.

[3]  G O'Grady,et al.  Multi‐channel wireless mapping of gastrointestinal serosal slow wave propagation , 2015, Neurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society.

[4]  Aydin Farajidavar,et al.  Towards a highly-scalable wireless implantable system-on-a-chip for gastric electrophysiology , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[5]  R. Fisher,et al.  American Gastroenterological Association technical review on the diagnosis and treatment of gastroparesis. , 2004, Gastroenterology.

[6]  Amir Javan-Khoshkholgh,et al.  An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[7]  R. McCallum,et al.  Gastric myoelectrical activity and gastric emptying in patients with functional dyspepsia , 1998, American Journal of Gastroenterology.

[8]  Maysam Ghovanloo,et al.  A Q-Modulation Technique for Efficient Inductive Power Transmission , 2015, IEEE Journal of Solid-State Circuits.