Numerical and experimental investigation of the operating characteristics of a “wickless” heat pipe

SYNOPSIS This paper describes existing numerical techniques used for simulating heat pipes, and the development of a simplified numerical model for normal wicked/wickless heat pipes based on the analysis of the current modelling methods. The model was used to investigate the operating characteristics of a “wickless” gravitational heat pipe, including variation of cross-sectional area, axial/radial velocity, pressure and temperature of liquid/vapour flows with height position above the liquid level. To validate the modelling predictions, a test rig was constructed to carry out laboratory testing, including measurement of surface temperatures and heat flow associated with the heat pipe heat transfer. Experimental results were found to be in general agreement with the numerical predictions when the test conditions were close to the simulation assumptions.

[1]  Xudong Zhao Investigation of a novel heat pipe solar collector/CHP system , 2003 .

[2]  I. V. Yagodkin,et al.  Physical principles of heat pipes , 1982 .

[3]  Amir Faghri,et al.  Heat Pipe Science And Technology , 1995 .

[4]  J. E. Kemme,et al.  SONIC LIMITATIONS AND STARTUP PROBLEMS OF HEAT PIPES. , 1970 .

[5]  E. S. Keddy,et al.  Transient performance investigation of a space power system heat pipe , 1986 .

[6]  N. Ghoniem,et al.  Vapor Dynamics of Heat Pipe Start-Up , 1991 .

[7]  Amir Faghri,et al.  A NUMERICAL ANALYSIS OF THE EFFECTS OF CONJUGATE HEAT TRANSFER, VAPOR COMPRESSIBILITY, AND VISCOUS DISSIPATION IN HEAT PIPES , 1989 .

[8]  J. Thome,et al.  Convective Boiling and Condensation , 1972 .

[9]  Basem S. Attili On the numerical study of the vapor flow characteristics of a slender cylindrical heat pipe , 1994 .

[10]  Mohamed S. El-Genk,et al.  A transient model for liquid metal heat pipes , 1988 .

[11]  Won Soon Chang,et al.  MATHEMATICAL MODELING OF THE TRANSIENT OPERATING CHARACTERISTICS OF A LOW-TEMPERATURE HEAT PIPE , 1985 .

[12]  Yiding Cao,et al.  TRANSIENT TWO-DIMENSIONAL COMPRESSIBLE ANALYSIS FOR HIGH-TEMPERATURE HEAT PIPES WITH PULSED HEAT INPUT , 1991 .

[13]  Won Soon Chang,et al.  Measurements of the transient behavior of a capillary structure under heavy thermal loading , 1984 .

[14]  A. Faghri,et al.  Experimental and Numerical Analysis of Low-Temperature Heat Pipes With Multiple Heat Sources , 1991 .

[15]  V. H. Ransom,et al.  ATHENA heat pipe transient model , 1987 .