Development of High-Frequency (>60 MHz) Intravascular Ultrasound (IVUS) Transducer by Using Asymmetric Electrodes for Improved Beam Profile

In most commercial single-element intravascular ultrasound (IVUS) transducers, with 20 MHz to 40 MHz center frequencies, a conductive adhesive is used to bond a micro-sized cable for the signal line to the surface of the transducer aperture (<1 mm × 1 mm size) where ultrasound beam is generated. Therefore, the vibration of the piezoelectric layer is significantly disturbed by the adhesive with the signal line, thereby causing problems, such as reduced sensitivity, shortened penetration depth, and distorted beam profile. This phenomenon becomes more serious as the center frequency of the IVUS transducer is increased, and the aperture size becomes small. Therefore, we propose a novel IVUS acoustic stack employing asymmetric electrodes with conductive and non-conductive backing blocks. The purpose of this study is to verify the extent of performance degradation caused by the adhesive with the signal line, and to demonstrate how much performance degradation can be minimized by the proposed scheme. Finite element analysis (FEA) simulation was conducted, and the results show that −3 dB, −6 dB, and −10 dB penetration depths of the conventional transducer were shortened by 20%, 25%, and 19% respectively, while those of the proposed transducer were reduced only 3%, 4%, and 0% compared with their ideal transducers which have the same effective aperture size. Besides, the proposed transducer improved the −3 dB, −6 dB, and −10 dB penetration depths by 15%, 12%, and 10% respectively, compared with the conventional transducer. We also fabricated a 60 MHz IVUS transducer by using the proposed technique, and high-resolution IVUS B-mode (brightness mode) images were obtained. Thus, the proposed scheme can be one of the potential ways to provide more uniform beam profile resulting in improving the signal to noise ratio (SNR) in IVUS image.

[1]  Qifa Zhou,et al.  Correspondence: Lead-free intravascular ultrasound transducer using BZT-50BCT ceramics , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[2]  Jonathan Mamou,et al.  High-frequency chirp ultrasound imaging with an annular array for ophthalmologic and small-animal imaging. , 2009, Ultrasound in medicine & biology.

[3]  Elsa D. Angelini,et al.  Lumen Border Detection of Intravascular Ultrasound via Denoising of Directional Wavelet Representations , 2009, FIMH.

[4]  M. Kern,et al.  4 – Intravascular Lesion Assessment: Physiology and Imaging , 2018 .

[5]  S. Rhee,et al.  60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging , 2008, 2008 IEEE Ultrasonics Symposium.

[6]  K. Shung,et al.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  A J Thrush,et al.  Measurement of resolution in intravascular ultrasound images , 1996, Physiological measurement.

[8]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[9]  R. Gilmore,et al.  High frequency focused ultrasonic transducer for invasive tissue characterization , 1990 .

[10]  Zhile Han,et al.  A High Frequency Geometric Focusing Transducer Based on 1-3 Piezocomposite for Intravascular Ultrasound Imaging , 2017, BioMed research international.

[11]  Qifa Zhou,et al.  Multi-frequency intravascular ultrasound (IVUS) imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[12]  Nassir Navab,et al.  A State-of-the-Art Review on Segmentation Algorithms in Intravascular Ultrasound (IVUS) Images , 2012, IEEE Transactions on Information Technology in Biomedicine.

[13]  M. Doyley,et al.  Delineation of Atherosclerotic Plaque Using Subharmonic Imaging Filtering Techniques and a Commercial Intravascular Ultrasound System , 2013, Ultrasonic imaging.

[14]  Jong Seob Jeong,et al.  Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging. , 2015, Sensors and actuators. A, Physical.

[15]  Wei Wu,et al.  80-MHz intravascular ultrasound transducer using PMN-PT free-standing film , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Xiaoning Jiang,et al.  Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography , 2015, Physics in medicine and biology.

[17]  J. Mamou,et al.  Chirp-coded excitation imaging with a high-frequency ultrasound annular array , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  Seiichi Hirota,et al.  Accuracy of OCT, grayscale IVUS, and their combination for the diagnosis of coronary TCFA: an ex vivo validation study. , 2015, JACC. Cardiovascular imaging.

[19]  Hairong Zheng,et al.  A novel dual-frequency imaging method for intravascular ultrasound applications. , 2015, Ultrasonics.

[20]  A. Gisolf,et al.  Transducer for harmonic intravascular ultrasound imaging , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  F Prati,et al.  Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries , 2001, Heart.

[22]  J. G. Fujimoto,et al.  Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound. , 1997, Heart.

[23]  Jianguo Ma,et al.  Ultrahigh Frequency (100 MHz–300 MHz) Ultrasonic Transducers for Optical Resolution Medical Imagining , 2016, Scientific Reports.