Method for simulating dose reduction in digital mammography using the Anscombe transformation

Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.

[1]  Ann-Katherine Carton,et al.  Development of a physical 3D anthropomorphic breast phantom. , 2011, Medical physics.

[2]  I. Cunningham Applied Linear-Systems Theory , 2000 .

[3]  S Suryanarayanan,et al.  Evaluation of an improved algorithm for producing realistic 3D breast software phantoms: application for mammography. , 2010, Medical physics.

[4]  Magnus Båth,et al.  Simulation of dose reduction in tomosynthesis. , 2009, Medical physics.

[5]  Ehsan Samei,et al.  Does image quality matter? Impact of resolution and noise on mammographic task performance. , 2007, Medical physics.

[6]  Andrew D. A. Maidment,et al.  Optimized generation of high resolution breast anthropomorphic software phantoms. , 2012, Medical physics.

[7]  Oliver Diaz,et al.  Image simulation and a model of noise power spectra across a range of mammographic beam qualities. , 2014, Medical physics.

[8]  A E Burgess,et al.  The Rose model, revisited. , 1999, Journal of the Optical Society of America. A, Optics, image science, and vision.

[9]  Wouter J. H. Veldkamp,et al.  A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography , 2008, Journal of Digital Imaging.

[10]  E. Samei,et al.  Dose dependence of mass and microcalcification detection in digital mammography: free response human observer studies. , 2007, Medical physics.

[11]  Nooshin Kiarashi,et al.  Development and Application of a Suite of 4-D Virtual Breast Phantoms for Optimization and Evaluation of Breast Imaging Systems , 2014, IEEE Transactions on Medical Imaging.

[12]  F. J. Anscombe,et al.  THE TRANSFORMATION OF POISSON, BINOMIAL AND NEGATIVE-BINOMIAL DATA , 1948 .

[13]  Ehsan Samei,et al.  A method for modifying the image quality parameters of digital radiographic images. , 2003, Medical physics.

[14]  J. K. Ord,et al.  Handbook of the Poisson Distribution , 1967 .

[15]  Nelson D. A. Mascarenhas,et al.  Mammographic Image Denoising and Enhancement Using the Anscombe Transformation, Adaptive Wiener Filtering, and the Modulation Transfer Function , 2013, Journal of Digital Imaging.

[16]  Hilde Bosmans,et al.  Power Spectrum Analysis of an Anthropomorphic Breast Phantom Compared to Patient Data in 2D Digital Mammography and Breast Tomosynthesis , 2014, Digital Mammography / IWDM.

[17]  E. W. Shrigley Medical Physics , 1944, British medical journal.

[18]  Nooshin Kiarashi,et al.  A second generation of physical anthropomorphic 3D breast phantoms based on human subject data , 2014, Medical Imaging.

[19]  Alessandro Foi,et al.  Optimal Inversion of the Generalized Anscombe Transformation for Poisson-Gaussian Noise , 2013, IEEE Transactions on Image Processing.

[20]  Nelson D. A. Mascarenhas,et al.  Transmission tomography under Poisson noise using the Anscombe transformation and Wiener filtering of the projections , 1999 .

[21]  L. Kochian Author to whom correspondence should be addressed , 2006 .

[22]  Anders Tingberg,et al.  Method of simulating dose reduction for digital radiographic systems. , 2005, Radiation protection dosimetry.

[23]  Alessandro Foi,et al.  Optimal Inversion of the Anscombe Transformation in Low-Count Poisson Image Denoising , 2011, IEEE Transactions on Image Processing.

[24]  Jacob Geleijns,et al.  Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography. , 2006, Radiology.

[25]  Dev P. Chakraborty,et al.  Potential for lower absorbed dose in digital mammography: a JAFROC experiment using clinical hybrid images with simulated dose reduction , 2006, SPIE Medical Imaging.

[26]  Kenneth C. Young,et al.  Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system. , 2012, Medical physics.

[27]  Andrew D. A. Maidment,et al.  Digital Mammography , 2019, Advances in Clinical Radiology.