Field study of thermal comfort in residential buildings in the equatorial hot-humid climate of Malaysia

An extensive field study has been carried out in non-air-conditioned residences in Kota Kinabalu city, in Malaysia for the prediction and evaluation of the effect of the indoor thermal environment on occupants' thermal comfort. A total of 890 responses over one year were gathered. The hot-humid indoor climates of the surveyed buildings have been described and analyzed in terms of air temperature, globe temperature, relative humidity, wind velocity. The clothing insulation ensemble and metabolic rate of the occupants were also characterized. In the aim to assess the comfort temperature in residential buildings in the hot-humid tropics, each analyzed variable was thoroughly compared with the results of two field studies located in the hot-humid tropics, one conducted in Jakarta by Feriadi and Wong [1] and the second in Singapore by de Dear et al. [2]. Multiple and stepwise regressions were applied for the selection of the independent variable for neutral temperature prediction. Air temperature was chosen as an index for the indoor thermal comfort. The comfort temperature was determined using various approaches. The predicted temperature was found to be nearly 30 °C regardless of the adopted approach. The indoor comfort temperature was close to the recorded mean indoor air temperature of all responses having a difference of about 0.7 °C. The mean and the recorded indoor range temperatures seem to have effect in the prediction of comfort temperature.

[1]  D. K. Weaver,et al.  Probit Analysis: Assessing Goodness-of-Fit Based on Backtransformation and Residuals , 1995 .

[2]  Joseph Andrew Clarke,et al.  Using results from field surveys to predict the effect of open windows on thermal comfort and energy use in buildings , 2007 .

[3]  Gail Brager,et al.  Operable windows, personal control and occupant comfort. , 2004 .

[4]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[5]  Viv Bewick,et al.  Statistics review 14: Logistic regression , 2005, Critical care.

[6]  A. Auliciems,et al.  Airconditioning in Australia I – human thermal factors , 1986 .

[7]  Chandra Sekhar,et al.  Thermal comfort evaluation of naturally ventilated public housing in Singapore , 2002 .

[8]  Mohd. Yusof Othman,et al.  The bioclimatic design approach to low-energy buildings in the Klang Valley, Malaysia , 1998 .

[9]  Richard D. De Veaux,et al.  Stats: Data and Models , 2007 .

[10]  J. L. M. Hensen,et al.  Literature review on thermal comfort in transient conditions , 1990 .

[11]  Richard de Dear,et al.  Field experiments on occupant comfort and office thermal environments in a hot-humid climate , 1994 .

[12]  Bjarne W. Olesen,et al.  Introduction to thermal comfort standards and to the proposed new version of EN ISO 7730 , 2002 .

[13]  C. G. Webb An Analysis of Some Observations of Thermal Comfort in an Equatorial Climate , 1959, British journal of industrial medicine.

[14]  F. Nicol Adaptive thermal comfort standards in the hot–humid tropics , 2004 .

[15]  Fred Bauman,et al.  Field study of the impact of a desktop task/ambient conditioning system in office buildings , 1998 .

[16]  Donatien Njomo,et al.  Thermal comfort: A review paper , 2010 .

[17]  A. Auliciems,et al.  THERMAL COMFORT CRITERIA FOR INDOOR DESIGN TEMPERATURES IN THE AUSTRALIAN WINTER , 1977 .

[18]  Richard de Dear,et al.  Combined thermal acceptability and air movement assessments in a hot humid climate , 2011 .

[19]  J. Neter,et al.  Applied Linear Regression Models , 1983 .

[20]  Sharafat Ali,et al.  Tropical summer index—a study of thermal comfort of Indian subjects , 1986 .

[21]  J. Busch A tale of two populations: thermal comfort in air-conditioned and naturally ventilated offices in Thailand , 1992 .

[22]  Gail Brager,et al.  Developing an adaptive model of thermal comfort and preference , 1998 .

[23]  N. Wong,et al.  Thermal comfort for naturally ventilated houses in Indonesia , 2004 .

[24]  Muhsin Kilic,et al.  Determination of required core temperature for thermal comfort with steady-state energy balance method , 2006 .

[25]  D. K. Tiller,et al.  A field study of office thermal comfort using questionnaire software , 1997 .

[26]  R. J. Dear,et al.  Thermal comfort in the humid tropics: Field experiments in air conditioned and naturally ventilated buildings in Singapore , 1991 .

[27]  Michael A. Humphreys,et al.  Field Studies of Indoor Thermal Comfort and the Progress of the Adaptive Approach , 2007 .

[28]  M. Cardoso,et al.  Rapid epidemiologic assessment of breastfeeding practices: probit analysis of current status data. , 1996, Journal of tropical pediatrics.

[29]  C. Bouden,et al.  An adaptive thermal comfort model for the Tunisian context: a field study results , 2005 .

[30]  Mario F. Triola Elementary Statistics Using Excel , 2000 .

[31]  Jan Hensen,et al.  Thermal comfort in residential buildings: Comfort values and scales for building energy simulation , 2009 .

[32]  Tri Harso Karyono,et al.  Report on thermal comfort and building energy studies in Jakarta—Indonesia , 2000 .