Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information.

PURPOSE X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information from a single-rotation CBCT scan. METHODS A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. RESULTS The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. CONCLUSIONS An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips.

[1]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[2]  J. Boone,et al.  An analytical model of the scattered radiation distribution in diagnostic radiology. , 1988, Medical physics.

[3]  Yeong Gil Shin,et al.  Fast hybrid CPU- and GPU-based CT reconstruction algorithm using air skipping technique. , 2010, Journal of X-ray science and technology.

[4]  D. Jaffray,et al.  The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors. , 2004, Medical physics.

[5]  Timothy D. Solberg,et al.  Scatter correction for cone-beam computed tomography using moving blocker strips: a preliminary study. , 2010 .

[6]  Lei Zhu,et al.  Scatter correction for cone-beam CT in radiation therapy. , 2009 .

[7]  S. Richard,et al.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. , 2005, Medical physics.

[8]  Ruola Ning,et al.  X-ray scatter correction algorithm for cone beam CT imaging. , 2004, Medical physics.

[9]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[10]  Brian Nett,et al.  Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy , 2011, Physics in medicine and biology.

[11]  Lei Zhu,et al.  Noise suppression in scatter correction for cone-beam CT. , 2009, Medical physics.

[12]  Peter Cloetens,et al.  Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography , 2010, Physics in medicine and biology.

[13]  Lei Zhu,et al.  X-ray scatter correction for cone-beam CT using moving blocker array , 2005, SPIE Medical Imaging.

[14]  Lei Xing,et al.  Fast and accurate marker-based projective registration method for uncalibrated transmission electron microscope tilt series , 2010, Physics in medicine and biology.

[15]  J. Dinten,et al.  A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setup , 2007, Physics in medicine and biology.

[16]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[17]  Sung Yong Shin,et al.  Image Metamorphosis with Scattered Feature Constraints , 1996, IEEE Trans. Vis. Comput. Graph..

[18]  Radhe Mohan,et al.  Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging , 2008, Physics in medicine and biology.

[19]  Ning Wen,et al.  Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT). , 2010, Medical physics.

[20]  Xiaochuan Pan,et al.  Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. , 2009, Medical physics.