Overgeneration from Solar Energy in California - A Field Guide to the Duck Chart

In 2013, the California Independent System Operator published the "duck chart,"" which shows a significant drop in mid-day net load on a spring day as solar photovoltaics (PV) are added to the system. The chart raises concerns that the conventional power system will be unable to accommodate the ramp rate and range needed to fully utilize solar energy, particularly on days characterized by the duck shape. This could result in "overgeneration"" and curtailed renewable energy, increasing its costs and reducing its environmental benefits. This paper explores the duck chart in detail, examining how much PV might need to be curtailed if additional grid flexibility measures are not taken, and how curtailment rates can be decreased by changing grid operational practices. It finds that under business-as-usual types of assumptions and corresponding levels of grid flexibility in California, solar penetrations as low as 20 percent of annual energy could lead to marginal curtailment rates that exceed 30 percent. However, by allowing (or requiring) distributed PV and storage (including new installations that are part of the California storage mandate) to provide grid services, system flexibility could be greatly enhanced. Doing so could significantly reduce curtailment and allow much greater penetration of variable generationmore » resources in achieving a 50 percent renewable portfolio standard. Overall, the work described in this paper points to the need to fully integrate distributed resources into grid system planning and operations to allow maximum use of the solar resource.« less

[1]  Nicholas W. Miller,et al.  Western Wind and Solar Integration Study Phase 3 – Frequency Response and Transient Stability , 2014 .

[2]  John Sterling,et al.  Treatment of Solar Generation in Electric Utility Resource Planning (Presentation) , 2013 .

[3]  Ryan Wiser,et al.  Strategies to mitigate declines in the economic value of wind and solar at high penetration in California , 2015 .

[4]  Kara Clark,et al.  Western Wind and Solar Integration Study , 2011 .

[5]  Andrew Mills,et al.  AN EVALUATION OF SOLAR VALUATION METHODS USED IN UTILITY PLANNING AND PROCUREMENT PROCESSES , 2013 .

[6]  Andrew D. Mills,et al.  Changes in the Economic Value of Variable Generation at High Penetration Levels:A Pilot Case Study of California , 2014 .

[7]  Paul Denholm,et al.  Analysis of Concentrating Solar Power with Thermal Energy Storage in a California 33% Renewable Scenario , 2013 .

[8]  Paul Denholm,et al.  Estimating the Value of Utility-Scale Solar Technologies in California Under a 40% Renewable Portfolio Standard (Report Summary) (Presentation) , 2014 .

[9]  Tam Hunt,et al.  BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA , 2005 .

[10]  Vahan Gevorgian,et al.  Investigating the Impacts of Wind Generation Participation in Interconnection Frequency Response , 2015, IEEE Transactions on Sustainable Energy.

[11]  Paul Denholm,et al.  Methods for Analyzing the Benefits and Costs of Distributed Photovoltaic Generation to the U.S. Electric Utility System , 2014 .

[12]  Paul Denholm,et al.  Grid Integration and the Carrying Capacity of the U.S. Grid to Incorporate Variable Renewable Energy , 2015 .

[13]  David Palchak,et al.  Eastern Renewable Generation Integration Study: Flexibility and High Penetrations of Wind and Solar; NREL (National Renewable Energy Laboratory) , 2015 .

[14]  L. Bird,et al.  Wind and Solar Energy Curtailment: Experience and Practices in the United States , 2014 .

[15]  D. Lew,et al.  The Western Wind and Solar Integration Study Phase 2 , 2013 .

[16]  Kathryn E. Johnson,et al.  A tutorial of wind turbine control for supporting grid frequency through active power control , 2012, 2012 American Control Conference (ACC).

[17]  Paul Denholm,et al.  Enabling Greater Penetration of Solar Power via the Use of CSP with Thermal Energy Storage , 2011 .