A method to measure shear strain with high spatial resolution in the arterial wall non-invasively in vivo by tracking zero-crossings of B-mode intensity gradients

We have previously shown that there is a distinct longitudinal movement of the arterial wall during a cardiac cycle. This movement is larger in the intima-media region than in the adventitial region which introduces a substantial shear strain within the arterial wall. Our previously developed echo-tracking algorithm measured this shear strain by tracking two separate echoes, one in the intima-media region and one in the adventitia region and thus only a linear distribution was evaluated. The objective of this study was to suggest and evaluate a new improved method which can measure the intramural shear strain with higher spatial resolution and thereby provide more information on this new and rather unknown phenomenon. The mean maximum shear strain was 0.82 radians with a standard deviation of 0.17 radians and a CV-value of 14.2%. The total mean difference in measured longitudinal movement between the new and previous method was 10µm with a standard deviation of 90µm and a CV-value of 12.8%. The spatial distribution of the intramural shear strain seems to be very non-linear with a large amount of shear strain occurring in a small section around the transition between the media and adventitia layers.

[1]  L. Brush,et al.  McDonaldʼs Blood Flow in Arteries , 1991 .

[2]  7C-2 Non-Invasive Measurements of Longitudinal Strain of the Arterial Wall , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[3]  Å. Ahlgren,et al.  Evaluation of an ultrasonic echo-tracking method for measurements of arterial wall movements in two dimensions , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Tomas Jansson,et al.  A new non‐invasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trial , 2003, Clinical physiology and functional imaging.

[5]  Tomas Jansson,et al.  Longitudinal movements and resulting shear strain of the arterial wall. , 2006, American journal of physiology. Heart and circulatory physiology.

[6]  T. Jansson,et al.  Non-invasive measurement of arterial longitudinal movement , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[7]  P. Tortoli,et al.  Methods for measurements of the longitudinal movement and the shear-induced longitudinal elastic modulus of the arterial wall , 2009, 2009 IEEE International Ultrasonics Symposium.

[8]  Spyretta Golemati,et al.  Carotid artery wall motion estimated from B-mode ultrasound using region tracking and block matching. , 2003, Ultrasound in medicine & biology.

[9]  Kazuhiro Sunagawa,et al.  Simultaneous measurement of blood flow and arterial wall vibrations in radial and axial directions , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[10]  Hiroshi Kanai,et al.  Basic Study on Detection of Outer Boundary of Arterial Wall Using Its Longitudinal Motion , 2007 .