Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI

A significant component of BOLD fMRI physiological noise is caused by variations in the depth and rate of respiration. It has previously been demonstrated that a breath-to-breath metric of respiratory variation (respiratory volume per time; RVT), computed from pneumatic belt measurements of chest expansion, has a strong linear relationship with resting-state BOLD signals across the brain. RVT is believed to capture breathing-induced changes in arterial CO(2), which is a cerebral vasodilator; indeed, separate studies have found that spontaneous fluctuations in end-tidal CO(2) (PETCO(2)) are correlated with BOLD signal time series. The present study quantifies the degree to which RVT and PETCO(2) measurements relate to one another and explain common aspects of the resting-state BOLD signal. It is found that RVT (particularly when convolved with a particular impulse response, the "respiration response function") is highly correlated with PETCO(2), and that both explain remarkably similar spatial and temporal BOLD signal variance across the brain. In addition, end-tidal O(2) is shown to be largely redundant with PETCO(2). Finally, the latency at which PETCO(2) and respiration belt measures are correlated with the time series of individual voxels is found to vary across the brain and may reveal properties of intrinsic vascular response delays.

[1]  G. Volgyesi,et al.  MRI mapping of cerebrovascular reactivity using square wave changes in end‐tidal PCO2 , 2001, Magnetic resonance in medicine.

[2]  G. Glover,et al.  Cerebral blood flow-related signal changes during breath-holding. , 1999, AJNR. American journal of neuroradiology.

[3]  Peter A. Bandettini,et al.  The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration , 2008, NeuroImage.

[4]  Ravi S. Menon,et al.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[5]  T. L. Davis,et al.  EPI Imaging of Global Increase of Brain MR Signal with Breath‐hold Preceded by Breathing O2 , 1995, Magnetic resonance in medicine.

[6]  Gary H. Glover,et al.  Controlled inspiration depth reduces variance in breath-holding-induced BOLD signal , 2008, NeuroImage.

[7]  A E Stillman,et al.  Functional MRI of brain during breath holding at 4 T. , 1995, Magnetic resonance imaging.

[8]  E. Bruce,et al.  Ventilatory variability induced by spontaneous variations of PaCO2 in humans. , 1994, Journal of applied physiology.

[9]  M. Blinkenberg,et al.  Regional Differences in the CBF and BOLD Responses to Hypercapnia: A Combined PET and fMRI Study , 2000, NeuroImage.

[10]  H. Hotelling The Selection of Variates for Use in Prediction with Some Comments on the General Problem of Nuisance Parameters , 1940 .

[11]  Eitan Prisman,et al.  Comparison of the effects of independently‐controlled end‐tidal PCO2 and PO2 on blood oxygen level–dependent (BOLD) MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[12]  J. Haxby,et al.  Localization of Cardiac-Induced Signal Change in fMRI , 1999, NeuroImage.

[13]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[14]  J. Mead,et al.  Measurement of the separate volume changes of rib cage and abdomen during breathing. , 1967, Journal of applied physiology.

[15]  G. Glover,et al.  Regularized higher‐order in vivo shimming , 2002, Magnetic resonance in medicine.

[16]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[17]  J Conway,et al.  A comparison of indirect methods for continuous estimation of arterial PCO2 in men. , 1990, Journal of applied physiology.

[18]  G. Glover,et al.  Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imaging , 2002, Magnetic resonance in medicine.

[19]  Peter A. Bandettini,et al.  Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI , 2006, NeuroImage.

[20]  E C Wong,et al.  A hypercapnia‐based normalization method for improved spatial localization of human brain activation with fMRI , 1997, NMR in biomedicine.

[21]  Catie Chang,et al.  Influence of heart rate on the BOLD signal: The cardiac response function , 2009, NeuroImage.

[22]  Gary H. Glover,et al.  Breath holding reveals differences in fMRI BOLD signal in children and adults , 2005, NeuroImage.

[23]  Karl J. Friston,et al.  Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.

[24]  G. Glover Deconvolution of Impulse Response in Event-Related BOLD fMRI1 , 1999, NeuroImage.

[25]  M. Moseley,et al.  Functional MRI of Human Brain during Breath Holding by BOLD and FAIR Techniques , 1999, NeuroImage.

[26]  Jeff H. Duyn,et al.  Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal , 2007, NeuroImage.

[27]  Catie Chang,et al.  Mapping and correction of vascular hemodynamic latency in the BOLD signal , 2008, NeuroImage.

[28]  J. Karemaker,et al.  Influence of chemoreflexes on respiratory variability in healthy subjects. , 2002, American journal of respiratory and critical care medicine.

[29]  G. Glover,et al.  Self‐navigated spiral fMRI: Interleaved versus single‐shot , 1998, Magnetic resonance in medicine.

[30]  Stephen D. Mayhew,et al.  Dynamic Forcing of End-Tidal Carbon Dioxide and Oxygen Applied to Functional Magnetic Resonance Imaging , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[31]  K. Nakada,et al.  Chronological analysis of physiological T2* signal change in the cerebrum during breath holding , 2001, Journal of magnetic resonance imaging : JMRI.

[32]  C. Duvivier,et al.  An inexpensive, MRI compatible device to measure tidal volume from chest-wall circumference , 2007, Physiological measurement.

[33]  David M. Simpson,et al.  Multivariate dynamic analysis of cerebral blood flow regulation in humans , 2000, IEEE Transactions on Biomedical Engineering.

[34]  G. Glover,et al.  Spiral‐in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts , 2001, Magnetic resonance in medicine.

[35]  Richard S. J. Frackowiak,et al.  Neural correlates of voluntary breathing in humans. , 2003, Journal of applied physiology.

[36]  Irene Tracey,et al.  Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal , 2004, NeuroImage.

[37]  R. S. Hinks,et al.  Time course EPI of human brain function during task activation , 1992, Magnetic resonance in medicine.

[38]  F. H. Lopes da Silva,et al.  A study of the brain's resting state based on alpha band power, heart rate and fMRI , 2008, NeuroImage.