Comparison of an accelerometer and a condenser microphone for mechanomyographic signals during measurement of agonist and antagonist muscles in sustained isometric muscle contractions.

The purpose of this study was to investigate the influence of the force tremor (FT) on mechanomyographic (MMG) signals recorded by a condenser microphone (MIC) and an accelerometer (ACC) during measurement of agonist and antagonist muscles in sustained isometric contractions. Surface electromyographic (EMG) signals and MMG signals by MIC (MMG-MIC) and ACC (MMG-ACC) were recorded simultaneously on biceps brachii (BB) and triceps brachii (TB). Following determination of the isometric maximum voluntary contraction (MVC), 10 male subjects were asked to perform sustained elbow flexion and extension contractions at 30% MVC until exhaustion. We analyzed the root mean square (RMS) for all signals and compared the sum of the power spectrum (SPA) for 3-6 Hz and 8-12 Hz and the ratio of the sum of SPA for 3-6 Hz and 8-12 Hz in SPA for 3-100 Hz (SPA-FT/SPA-(3-100 Hz)) between MMG-MIC and MMG-ACC. During all sustained muscle contractions, the RMS of EMG and MMG-(MIC) was significantly (p<0.05) increased in antagonistic muscle pairs, while the increase was more noticeable for the agonist than for the antagonist. In addition, the antagonist had a significantly (p<0.05) smaller amplitude than the agonist muscle. The RMS of MMG-ACC, however, showed no significant (p>0.05) difference in RMS amplitude and slope between agonist and antagonist muscles during flexion. In extension, the MMG-ACC-RMS amplitude showed a tendency to be higher in the antagonist than in the agonist, while their slopes showed no significant (p>0.05) difference. The SPA for 3-6 Hz and 8-12 Hz in MMG-(MIC) showed a tendency to be higher in the agonist than the antagonist, and the slopes of the agonist were significantly (p<0.05) higher than those of the antagonist in all contractions. In MMG-ACC, SPA and slopes for 3-6 Hz and 8-12 Hz tended not to differ between agonist and antagonist. The SPA-FT/SPA-(3-100 Hz) in MMG-ACC showed that the antagonist was higher than that of the agonist in all contractions. The MMG-(MIC), however, showed a tendency toward no difference between the agonist and antagonist. In the assessment of muscle activity during simultaneous measurement of the agonist and antagonist during sustained muscle contractions, the MMG signal detected by MIC appeared to be less affected by FT than by ACC due to the different inherent characteristics of the two transducers.

[1]  G. Ebenbichler,et al.  The role of the biarticular agonist and cocontracting antagonist pair in isometric muscle fatigue , 1998, Muscle & nerve.

[2]  M. Tarata Mechanomyography versus Electromyography, in monitoring the muscular fatigue , 2003, Biomedical engineering online.

[3]  A. Holbourn,et al.  The sounds from single motor units in a contracting muscle , 1948, The Journal of physiology.

[4]  B. Bigland-ritchie,et al.  Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.

[5]  D. Delpy,et al.  Local temperature changes and human skeletal muscle metabolism. , 2001, Journal of physiological anthropology and applied human science.

[6]  Dario Farina,et al.  Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions , 2006, Medical and Biological Engineering and Computing.

[7]  K. Akataki,et al.  Technical aspects of mechnomyography recording with piezoelectric contact sensor , 1998, Medical and Biological Engineering and Computing.

[8]  J. Daube,et al.  Muscles Alive , 1981, Neurology.

[9]  Y Shimomura,et al.  Changes in surface EMG and acoustic myogram parameters during static fatiguing contractions until exhaustion: influence of elbow joint angles. , 2001, Journal of physiological anthropology and applied human science.

[10]  G. Sjøgaard,et al.  Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode , 2002, European Journal of Applied Physiology.

[11]  S. Delp,et al.  The isometric functional capacity of muscles that cross the elbow. , 2000, Journal of biomechanics.

[12]  R. Perini,et al.  Muscular sound and force relationship during isometric contraction in man , 2006, European Journal of Applied Physiology and Occupational Physiology.

[13]  O. Lippold,et al.  The 4‐6 HZ tremor during sustained contraction in normal human subjects. , 1983, The Journal of physiology.

[14]  R. Merletti,et al.  Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles , 2006, Medical and Biological Engineering and Computing.

[15]  M. Stokes,et al.  Technical aspects of acoustic myography (AMG) of human skeletal muscle: contact pressure and force/AMG relationships , 1993, Journal of Neuroscience Methods.

[16]  Joseph P. Weir,et al.  Mechanomyographic and electromyographic responses during fatigue in humans: influence of muscle length , 2000, European Journal of Applied Physiology.

[17]  G C Elder,et al.  Variability of fiber type distributions within human muscles. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[18]  C. J. Luca Myoelectrical manifestations of localized muscular fatigue in humans. , 1984 .

[19]  H. Yack,et al.  Acoustic myography as an indicator of force during sustained contractions of a small hand muscle. , 1991, Journal of applied physiology.

[20]  C. Orizio Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. , 1993, Critical reviews in biomedical engineering.

[21]  Changes of muscle activation pattern during fatiguing sustained contraction , 1997 .

[22]  P. Rack,et al.  Different types of tremor in the human thumb. , 1982, The Journal of physiology.

[23]  Pascal Madeleine,et al.  A comparison between mechanomyographic condenser microphone and accelerometer measurements during submaximal isometric, concentric and eccentric contractions. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[24]  Benno M Nigg,et al.  Muscle activity damps the soft tissue resonance that occurs in response to pulsed and continuous vibrations. , 2002, Journal of applied physiology.

[25]  M Solomonow,et al.  Motor unit recruitment strategy of antagonist muscle pair during linearly increasing contraction. , 1997, Electromyography and clinical neurophysiology.

[26]  T Moritani,et al.  The muscle sound properties of different muscle fiber types during voluntary and electrically induced contractions. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[27]  Y Shimomura,et al.  The effect of mental loads on muscle tension, blood pressure and blink rate. , 2000, Journal of physiological anthropology and applied human science.

[28]  M. Watakabe,et al.  Mechanical behaviour of condenser microphone in mechanomyography , 2001, Medical and Biological Engineering and Computing.

[29]  A. Prochazka,et al.  Instability in human forearm movements studied with feed‐back‐controlled muscle vibration. , 1988, The Journal of physiology.

[30]  E Cafarelli,et al.  Behavior of coactive muscles during fatigue. , 1993, Journal of applied physiology.

[31]  D T Barry,et al.  Acoustic signals from frog skeletal muscle. , 1987, Biophysical journal.

[32]  L. Lindstrom,et al.  Muscular fatigue and action potential conduction velocity changes studied with frequency analysis of EMG signals. , 1970, Electromyography.

[33]  Masahiko Sato Frequency Components of the Electromyogram Led with the Bipolar Surface Electrodes , 1964 .

[34]  C. Orizio,et al.  Changes of muscular sound during sustained isometric contraction up to exhaustion. , 1989, Journal of applied physiology.

[35]  M. Stokes,et al.  Acoustic myography for investigating human skeletal muscle fatigue. , 1991, Journal of applied physiology.

[36]  Joseph P Weir,et al.  Comparison of a piezoelectric contact sensor and an accelerometer for examining mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii. , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[37]  J. S. Jaffe,et al.  Low frequency sounds from sustained contraction of human skeletal muscle. , 1980, Biophysical journal.

[38]  B. Maton,et al.  The fatigability of two agonistic muscles in human isometric voluntary submaximal contraction: an EMG study , 2004, European Journal of Applied Physiology and Occupational Physiology.

[39]  C. D. De Luca,et al.  Myoelectrical manifestations of localized muscular fatigue in humans. , 1984, Critical reviews in biomedical engineering.

[40]  V. Dietz,et al.  Neuronal mechanisms underlying physiological tremor. , 1978, Journal of neurophysiology.

[41]  Spectrum analysis of the mechanomyogram: elimination of the longitudinal shortening component of muscle fibers , 2000 .