Mixed mode fracture behaviour of steel fibre reinforced concrete

In this paper, results are reported for a series of discrete end hooked and straight fibre pullout tests subjected to mixed mode action with the results compared to that of discrete fibres pulled out in Mode I (tensile) and Mode II (shear) fracture. As has been previously observed from Modes I and II fracture tests, the snubbing effect dominates the behaviour of fibres at large fibre bending angles. At large fibre bending angles, considerable slip and crack separation occurred prior to the fibres being engaged in taking load and fibres that are inclined close to the cracked surface are ineffective in carrying load. The results of the test were compared with the fibre engagement and bond stress models in the Unified Variable Engagement Model (UVEM). A good correlation is observed for the UVEM model with the test data and provides further confirmation of the validity of the UVEM model to predict the mix mode fracture of steel fibre reinforced concrete.

[1]  Stephen J. Foster,et al.  The application of steel-fibres as concrete reinforcement in Australia: from material to structure , 2009 .

[2]  Antoine E. Naaman,et al.  EFFECT OF MORTAR FINENESS AND ADHESIVE AGENTS ON PULLOUT RESPONSE OF STEEL FIBERS , 2000 .

[3]  Sidney Mindess,et al.  Fibre Reinforced Cementitious Composites , 1990 .

[4]  J. P. Romualdi,et al.  Tensile Strength of Concrete Affected by Uniformly Distributed and Closely Spaced Short Lengths of Wire Reinforcement , 1964 .

[5]  Simon A. Austin,et al.  Pull-out behaviour of hooked steel fibres , 2002 .

[6]  S. Foster,et al.  Behaviour of steel fibre reinforced mortar in shear I : direct shear testing , 2006 .

[7]  Gordon B. Batson,et al.  Behavior of Reinforced Concrete Beams with Closely Spaced Reinforcement , 1963 .

[8]  Michael P. Collins,et al.  Development of the 2004 Canadian Standards Association (CSA) A23.3 shear provisions for reinforced concrete , 2006 .

[9]  J. Morton,et al.  The cracking of composites consisting of discontinuous ductile fibres in a brittle matrix — effect of fibre orientation , 1974 .

[10]  Victor C. Li,et al.  Postcrack Scaling Relations for Fiber Reinforced Cementitious Composites , 1992 .

[11]  Stephen J. Foster,et al.  Fracture of Steel Fibre Reinforced Concrete – The Unified Variable Engagement Model , 2012 .

[12]  P.J.M. Bartos,et al.  Inclined tensile strength of steel fibres in a cement-based composite , 1994 .

[13]  V. S. Gopalaratnam,et al.  Tensile Failure of Steel Fiber‐Reinforced Mortar , 1987 .