Calibration beads containing luminescent lanthanide ion complexes

The reliability of lanthanide luminescence measurements, by both flow cytometry and digital microscopy, will be enhanced by the availability of narrow-band emitting lanthanide calibration beads. These beads can also be used to characterize spectrographic instruments, including microscopes. Methods: 0.5, 3, and 5 micron (µm) beads containing a luminescent europium-complex were manufactured and the luminescence distribution of the 5 µm beads was measured with a time-delayed luminescence flow cytometer and a timedelayed digital microscope. The distribution of the luminescence intensity from the europium-complex in individual beads was determined on optical sections by confocal microscopy. The emission spectra of the beads under UV excitation were determined with a PARISS® spectrophotometer. The kinetics of the luminescence bleaching caused by UV irradiation were measured under LED excitation with a fluorescence microscope. Results: The kinetics of UV bleaching were very similar for the 0.5, 3, and 5 µm beads. Emission peaks were found at 592, 616, and 685 nanometers (nm). The width of the principal peak at half-maximum (616 nm) was 9.9 nm. The luminescence lifetimes in water and in air were 340 and 460 microseconds (µs), respectively. The distribution of the europium- complex in the beads was homogeneous. Conclusions: The 5 µm beads can be used for spectral calibration of microscopes equipped with a spectrograph, as test particles for time-delayed luminescence flow cytometers, and possibly as labels for macromolecules and cells.

[1]  Sean Yang,et al.  Increasing lanthanide luminescence by use of the RETEL effect , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[2]  Robert M Zucker,et al.  Reliability of confocal microscopy spectral imaging systems: Use of multispectral beads , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[3]  Sean Yang,et al.  UV LED excited time-gated luminescence flow cytometry: evaluation for rare-event particle counting , 2008, SPIE BiOS.

[4]  Robert M Zucker,et al.  Evaluation of confocal microscopy system performance. , 2001, Methods in molecular biology.

[5]  R M Zucker,et al.  Practical confocal microscopy and the evaluation of system performance. , 1999, Methods.

[6]  Dayong Jin,et al.  Practical time‐gated luminescence flow cytometry. II: Experimental evaluation using UV LED excitation , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[7]  Dayong Jin,et al.  Practical time‐gated luminescence flow cytometry. I: Concepts , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[8]  Sean Yang,et al.  Increasing the luminescence of lanthanide complexes , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[9]  Jeremy M Lerner,et al.  Wavelength and alignment tests for confocal spectral imaging systems , 2005, Microscopy research and technique.

[10]  Jeremy M Lerner,et al.  Calibration and validation of confocal spectral imaging systems , 2004, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[11]  John W. Williams,et al.  Progress in the use of Quantum Dye Eu(III)-macrocycles , 2003, SPIE BiOS.

[12]  Dayong Jin,et al.  High intensity solid‐state UV source for time‐gated luminescence microscopy , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.