Performance of the PTB reconstructed primary clock CS1 and an estimate of its current uncertainty

The paper describes the current performance of the primary clock CS1 of the Physikalisch-Technische Bundesanstalt (PTB). The clock employs a thermal atomic beam and magnetic state selection. After major reconstruction during 1995 and 1996, routine clock operation was restarted in May 1997. Results of comparisons with UTC(PTB) and other internationally recognized time scales are presented. An evaluation of the CS1 Type B uncertainty yielded 7 × 10-15 (1σ). The CS1 is thus the most accurate atomic clock in continuous operation world-wide.

[1]  P. Lugol Annalen der Physik , 1906 .

[2]  Andreas Bauch,et al.  Experimental Verification of the Shift of the Cesium Hyperfine Transition Frequency due to Blackbody Radiation , 1997 .

[3]  Jon H. Shirley,et al.  A new cavity configuration for cesium beam primary frequency standards , 1988 .

[4]  G. Becker Recent progress in primary Cs beam frequency standards at the PTB , 1976, IEEE Transactions on Instrumentation and Measurement.

[5]  J. Shirley,et al.  Velocity distributions calculated from the Fourier transforms of Ramsey lineshapes , 1997 .

[6]  B Guinot Application of general relativity to metrology , 1997 .

[7]  J. Vanier,et al.  The quantum physics of atomic frequency standards , 1989 .

[8]  Andreas Bauch,et al.  Frequency shifts in a cesium atomic clock due to Majorana transitions , 1993 .

[9]  J. Levine,et al.  Impact of new high stability frequency standards on the performance of the NIST AT1 time scale , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Spatial phase variations in a TE/sub 011/ microwave cavity for use in a cesium fountain primary frequency standard , 1993 .

[11]  Claude Audoin,et al.  Frequency Offset Due to Spectral Impurities in Cesium-Beam Frequency Standards , 1978, IEEE Transactions on Instrumentation and Measurement.

[12]  Gerhard Becker Research on Cs Beam Frequency Standards at the PTB: Beam Optics, Majorana Transitions , 1978, IEEE Transactions on Instrumentation and Measurement.

[13]  Molecular Beams , 1938, Nature.

[14]  K Dorenwendt,et al.  Realization and Dissemination of the Second , 1986 .

[15]  L. Pichon,et al.  Investigation of microwave π transitions in cesium beam clocks operated with U‐shaped H plane waveguide cavities , 1995 .

[16]  Robin P. Giffard,et al.  Frequency pulling by hyperfine σ transitions in cesium beam atomic frequency standards , 1991 .

[17]  Andreas Bauch,et al.  The PTB primary clock CS3: type B evaluation of its standard uncertainty , 1996 .

[18]  Wayne M. Itano,et al.  Shift of 2 S 12 hyperfine splittings due to blackbody radiation , 1982 .

[19]  G. D. Rovera,et al.  Rabi pedestal shifts as a diagnostic tool for primary frequency standards , 1994 .

[20]  A. Premoli,et al.  Pulling by Neighbouring Transitions and its Effects on the Performance of Caesium-Beam Frequency Standards , 1984 .

[21]  André Clairon,et al.  Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain , 1998 .

[22]  Andreas Bauch,et al.  Measurement of the Frequency-Shift Due to Distributed Cavity Phase Difference in an Atomic Clock , 1985, IEEE Transactions on Instrumentation and Measurement.