A quantum accounting and detective quantum efficiency analysis for video-based portal imaging.

The quality of images generated with radiographic imaging systems can be degraded if an inadequate number of secondary quanta are used at any stage before production of the final image. A theoretical technique known as a "quantum accounting diagram" (QAD) analysis has been developed recently to predict the detective quantum efficiency (DQE) of an imaging system as a function of spatial frequency based on an analysis of the propagation of quanta. It is used to determine the "quantum sink" stage(s) (stages which degrade the DQE of an imaging system due to quantum noise caused by a finite number of quanta), and to suggest design improvements to maximize image quality. We have used this QAD analysis to evaluate a video-based portal imaging system to determine where changes in design will have the most benefit. The system consists of a thick phosphor layer bonded to a 1 mm thick copper plate which is viewed by a T.V. camera. The imaging system has been modeled as ten cascaded stages, including: (i) conversion of x-ray quanta to light quanta; (ii) collection of light by a lens; (iii) detection of light quanta by a T.V. camera; (iv) the various blurring processes involved with each component of the imaging system; and, (v) addition of noise from the T.V. camera. The theoretical DQE obtained with the QAD analysis is in excellent agreement with the experimental DQE determined from previously published data. It is shown that the DQE is degraded at low spatial frequencies (< 0.25 cycles/mm) by quantum sinks both in the number of detected x rays and the number of detected optical quanta. At higher spatial frequencies, the optical quantum sink becomes the limiting factor in image quality. The secondary quantum sinks can be prevented, up to a spatial frequency of 0.5 cycles/mm, by increasing the overall system gain by a factor of 9 or more, or by improving the modulation transfer function (MTF) of components in the optical chain.

[1]  A Fenster,et al.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems. , 1994, Medical physics.

[2]  Andrew D. A. Maidment,et al.  Analysis of signal propagation in optically coupled detectors for digital mammography: II. Lens and fibre optics. , 1996, Physics in medicine and biology.

[3]  A Fenster,et al.  A digital fluoroscopic imaging device for radiotherapy localization. , 1990, International journal of radiation oncology, biology, physics.

[4]  A F Bielajew,et al.  Calculation of water/air stopping-power ratios using EGS4 with explicit treatment of electron-positron differences. , 1991, Medical physics.

[5]  A Fenster,et al.  Therapy imaging: a signal-to-noise analysis of metal plate/film detectors. , 1987, Medical physics.

[6]  David W. O. Rogers,et al.  Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transport , 1986 .

[7]  D. Rogers Fluence to dose equivalent conversion factors calculated with EGS3 for electrons from 100 keV to 20 GeV and photons from 11 keV to 20 GeV. , 1984, Health physics.

[8]  B R Paliwal,et al.  Monte Carlo and convolution dosimetry for stereotactic radiosurgery. , 1990, International journal of radiation oncology, biology, physics.

[9]  P. Munro,et al.  Optimal radiographic magnification for portal imaging. , 1994, Medical physics.

[10]  Majid Rabbani,et al.  Analysis of signal and noise propagation for several imaging mechanisms , 1989 .

[11]  M C Kirby,et al.  The consequences of fixed-pattern noise and image movement on electronic portal images. , 1996, Physics in medicine and biology.

[12]  J A Rowlands,et al.  Wiener noise power spectra of radiological television systems using a digital oscilloscope. , 1990, Medical physics.

[13]  J. Coltman The Specification of Imaging Properties by Response to a Sine Wave Input , 1954 .

[14]  S. Shalev,et al.  Monte Carlo optimization of metal/phosphor screens at megavoltage energies. , 1993, Medical physics.

[15]  A Fenster,et al.  Therapy imaging: a signal-to-noise analysis of a fluoroscopic imaging system for radiotherapy localization. , 1990, Medical physics.

[16]  Rodney Shaw,et al.  Principles Governing The Transfer Of Signal Modulation And Photon Noise By Amplifying And Scattering Mechanisms , 1985, Medical Imaging.

[17]  R T Droege A megavoltage MTF measurement technique for metal screen-film detectors. , 1979, Medical physics.

[18]  Measurement of quantum noise in fluoroscopic systems for portal imaging. , 1996, Medical physics.

[19]  R H MORGAN,et al.  Screen intensification systems and their limitations. , 1949, The American journal of roentgenology and radium therapy.

[20]  Aaron Fenster,et al.  Visual impact of the nonzero spatial frequency quantum sink , 1994, Medical Imaging.

[21]  Arthur G. Haus,et al.  The Physics of Medical Imaging: Recording System Measurements and Techniques , 1979 .

[22]  M. Rabbani,et al.  Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[23]  Gilbert Zweig,et al.  Radioluminescent Imaging: Factors Affecting Total Light Output , 1983, Other Conferences.

[24]  M J Yaffe,et al.  Effect of finite phosphor thickness on detective quantum efficiency. , 1989, Medical physics.

[25]  J Yorkston,et al.  Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays. , 1992, Medical physics.

[26]  A. Fenster,et al.  A "stochastic" convolution that describes both image blur and image noise using linear-systems theory , 1995, Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society.

[27]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[28]  P. Judy,et al.  The line spread function and modulation transfer function of a computed tomographic scanner. , 1976, Medical physics.

[29]  A Fenster,et al.  Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography. , 1995, Medical physics.