Double Minimum Variance Beamforming Method to Enhance Photoacoustic Imaging

One of the common algorithms used to reconstruct photoacoustic (PA) images is the non-adaptive Delayand-Sum (DAS) beamformer. However, the quality of the reconstructed PA images obtained by DAS is not satisfying due to its high level of sidelobes and wide mainlobe. In contrast, adaptive beamformers, such as minimum variance (MV), result in an improved image compared to DAS. In this paper, a novel beamforming method, called Double MV (D-MV) is proposed to enhance the image quality compared to the MV. It is shown that there is a summation procedure between the weighted subarrays in the output of the MV beamformer. This summation can be interpreted as the non-adaptive DAS beamformer. It is proposed to replace the existing DAS with the MV algorithm to reduce the contribution of the off-axis signals caused by the DAS beamformer between the weighted subarrays. The numerical results show that the proposed technique improves the full-width-half-maximum (FWHM) and signal-to-noise ratio (SNR) for about 28.83 μm and 4.8 dB in average, respectively, compared to MV beamformer. Also, quantitative evaluation of the experimental results indicates that the proposed D-MV leads to 0.15 mm and 1.96 dB improvement in FWHM and SNR, in comparison with MV beamformer. © 2018 Optical Society of America

[1]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[2]  Randy L. Haupt,et al.  Introduction to Adaptive Arrays , 1980 .

[3]  Minghua Xu,et al.  Time-domain reconstruction for thermoacoustic tomography in a spherical geometry , 2002, IEEE Transactions on Medical Imaging.

[4]  Minghua Xu,et al.  Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries , 2003, IEEE Transactions on Biomedical Engineering.

[5]  Xueding Wang,et al.  High-resolution photoacoustic tomography , 2004, The 17th Annual Meeting of the IEEELasers and Electro-Optics Society, 2004. LEOS 2004..

[6]  S. Holm,et al.  P2B-13 Speckle Statistics in Adaptive Beamforming , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[7]  A. Austeng,et al.  Adaptive Beamforming Applied to Medical Ultrasound Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Suhyun Park,et al.  10A-5 Beamforming for Photoacoustic Imaging Using Linear Array Transducer , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[9]  Manojit Pramanik,et al.  Design and evaluation of a novel breast cancer detection system combining both thermoacoustic (TA) and photoacoustic (PA) tomography. , 2008, Medical physics.

[10]  Xu Xiao Photoacoustic imaging in biomedicine , 2008 .

[11]  Lihong V. Wang Multiscale photoacoustic microscopy and computed tomography. , 2009, Nature photonics.

[12]  Pai-Chi Li,et al.  MVDR-based coherence weighting for high-frame-rate adaptive imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Lihong V. Wang,et al.  Thermoacoustic and photoacoustic sensing of temperature. , 2009, Journal of biomedical optics.

[14]  A. Austeng,et al.  Benefits of minimum-variance beamforming in medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[16]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[17]  Tianfu Wang,et al.  Forward-backward minimum variance beamforming combined with coherence weighting applied to ultrasound imaging , 2012, BioMed 2012.

[18]  Sverre Holm,et al.  Eigenspace Based Minimum Variance Beamforming Applied to Ultrasound Imaging of Acoustically Hard Tissues , 2012, IEEE Transactions on Medical Imaging.

[19]  Huabei Jiang,et al.  Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy , 2012, Biomedical optics express.

[20]  S. Emelianov,et al.  Photoacoustic Imaging for Cancer Detection and Staging. , 2013, Current molecular imaging.

[21]  Lihong V. Wang,et al.  Ultrasonically encoded photoacoustic flowgraphy in biological tissue. , 2013, Physical review letters.

[22]  Junjie Yao,et al.  Sensitivity of photoacoustic microscopy , 2014, Photoacoustics.

[23]  Lihong V. Wang,et al.  Small-Animal Whole-Body Photoacoustic Tomography: A Review , 2014, IEEE Transactions on Biomedical Engineering.

[24]  Stanislav Emelianov,et al.  Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging , 2014 .

[25]  Paul Kumar Upputuri,et al.  Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system. , 2015, Biomedical optics express.

[26]  Matthew O'Donnell,et al.  Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[27]  Giovanni Magenes,et al.  The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging , 2015, IEEE Transactions on Medical Imaging.

[28]  Ali Mahloojifar,et al.  Medical photoacoustic beamforming using minimum variance-based delay multiply and sum , 2017, Other Conferences.

[29]  Ali Mahloojifar,et al.  Image enhancement and noise reduction using modified Delay-Multiply-and-Sum beamformer: Application to medical photoacoustic imaging , 2017, 2017 Iranian Conference on Electrical Engineering (ICEE).

[30]  Ali Hariri,et al.  Photoacoustic signal enhancement: towards utilization of very low-cost laser diodes in photoacoustic imaging , 2017, BiOS.

[31]  Paul Kumar Upputuri,et al.  Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system. , 2017, Journal of biomedical optics.

[32]  Ali Mahloojifar,et al.  Eigenspace-based minimum variance adaptive beamformer combined with delay multiply and sum: experimental study , 2017, BiOS.

[33]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging. , 2017, Ultrasound in medicine & biology.

[34]  Ali Mahloojifar,et al.  Linear-array photoacoustic imaging using minimum variance-based delay multiply and sum adaptive beamforming algorithm , 2018, Journal of biomedical optics.

[35]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging , 2018, IEEE Transactions on Biomedical Engineering.