Resting and Postexercise Heart Rate Detection From Fingertip and Facial Photoplethysmography Using a Smartphone Camera: A Validation Study

Background Modern smartphones allow measurement of heart rate (HR) by detecting pulsatile photoplethysmographic (PPG) signals with built-in cameras from the fingertips or the face, without physical contact, by extracting subtle beat-to-beat variations of skin color. Objective The objective of our study was to evaluate the accuracy of HR measurements at rest and after exercise using a smartphone-based PPG detection app. Methods A total of 40 healthy participants (20 men; mean age 24.7, SD 5.2 years; von Luschan skin color range 14-27) underwent treadmill exercise using the Bruce protocol. We recorded simultaneous PPG signals for each participant by having them (1) facing the front camera and (2) placing their index fingertip over an iPhone’s back camera. We analyzed the PPG signals from the Cardiio-Heart Rate Monitor + 7 Minute Workout (Cardiio) smartphone app for HR measurements compared with a continuous 12-lead electrocardiogram (ECG) as the reference. Recordings of 20 seconds’ duration each were acquired at rest, and immediately after moderate- (50%-70% maximum HR) and vigorous- (70%-85% maximum HR) intensity exercise, and repeated successively until return to resting HR. We used Bland-Altman plots to examine agreement between ECG and PPG-estimated HR. The accuracy criterion was root mean square error (RMSE) ≤5 beats/min or ≤10%, whichever was greater, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation EC-13 standard. Results We analyzed a total of 631 fingertip and 626 facial PPG measurements. Fingertip PPG-estimated HRs were strongly correlated with resting ECG HR (r=.997, RMSE=1.03 beats/min or 1.40%), postmoderate-intensity exercise (r=.994, RMSE=2.15 beats/min or 2.53%), and postvigorous-intensity exercise HR (r=.995, RMSE=2.01 beats/min or 1.93%). The correlation of facial PPG-estimated HR was stronger with resting ECG HR (r=.997, RMSE=1.02 beats/min or 1.44%) than with postmoderate-intensity exercise (r=.982, RMSE=3.68 beats/min or 4.11%) or with postvigorous-intensity exercise (r=.980, RMSE=3.84 beats/min or 3.73%). Bland-Altman plots showed better agreement between ECG and fingertip PPG-estimated HR than between ECG and facial PPG-estimated HR. Conclusions We found that HR detection by the Cardiio smartphone app was accurate at rest and after moderate- and vigorous-intensity exercise in a healthy young adult sample. Contact-free facial PPG detection is more convenient but is less accurate than finger PPG due to body motion after exercise.

[1]  R. Dellavalle,et al.  Mobile medical and health apps: state of the art, concerns, regulatory control and certification , 2014, Online journal of public health informatics.

[2]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .

[3]  M. Yalçın,et al.  Time to use mobile health devices to diagnose paroxysmal atrial fibrillation. , 2016, International journal of cardiology.

[4]  P. Wattanapan,et al.  Correlation Between Skin Color Evaluation by Skin Color Scale Chart and Narrowband Reflectance Spectrophotometer , 2014, Indian journal of dermatology.

[5]  D. Hosmer,et al.  Maximal oxygen intake and nomographic assessment of functional aerobic impairment in cardiovascular disease. , 1973, American heart journal.

[6]  Jens Eckstein,et al.  Validation of a New Heart Rate Measurement Algorithm for Fingertip Recording of Video Signals with Smartphones. , 2016, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[7]  George Demiris,et al.  Older adults and mobile phones for health: A review , 2013, J. Biomed. Informatics.

[8]  Ming-Zher Poh,et al.  Diagnostic Performance of a Smartphone‐Based Photoplethysmographic Application for Atrial Fibrillation Screening in a Primary Care Setting , 2016, Journal of the American Heart Association.

[9]  Martin Leahy,et al.  Investigating a smartphone imaging unit for photoplethysmography , 2010, Physiological measurement.

[10]  Kwang Suk Park,et al.  Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Syed Ali Hussain,et al.  A qualitative study of user perceptions of mobile health apps , 2016, BMC Public Health.

[12]  Illhoi Yoo,et al.  A Systematic Review of Healthcare Applications for Smartphones , 2012, BMC Medical Informatics and Decision Making.

[13]  Enrico Caiani,et al.  Acquisition and analysis of cardiovascular signals on smartphones: potential, pitfalls and perspectives , 2014, European journal of preventive cardiology.

[14]  L Léger,et al.  Heart Rate Monitors: Validity, Stability, and Functionality. , 1988, The Physician and sportsmedicine.

[15]  J. Chong,et al.  PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application , 2016, Journal of cardiovascular electrophysiology.

[16]  Daniel McDuff,et al.  Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam , 2011, IEEE Transactions on Biomedical Engineering.

[17]  W. Nilsen,et al.  Health behavior models in the age of mobile interventions: are our theories up to the task? , 2011, Translational behavioral medicine.

[18]  Rosalind W. Picard,et al.  Non-contact, automated cardiac pulse measurements using video imaging and blind source separation , 2022 .

[19]  Urs-Vito Albrecht,et al.  mHealth 2.0: Experiences, Possibilities, and Perspectives , 2014, JMIR mHealth and uHealth.

[20]  Becky Freeman,et al.  Pro-smoking apps for smartphones: the latest vehicle for the tobacco industry? , 2012, Tobacco Control.

[21]  R. Laukkanen,et al.  Heart rate monitors: state of the art. , 1998, Journal of sports sciences.

[22]  C. Goodman Association for the Advancement of Medical Instrumentation , 1988 .