Parametric analysis of flow in the intramyocardial circulation

AbstractA simple mathematical model of the intramyocardial circulation has been utilized to provide a better understanding of coronary blood flow. The model includes three myocardial layers, each characterized by a three-parameter windkessel with one capacitance and two resistances. The effects of the beating heart are taken into account by means of an intramyocardial pump and the possible collapse of the vessels by an elevated backpressure. The three basic parameters that govern the flow are a normalized time constant, $$\bar \tau $$ , the total resistance, Rt, and a parameter, α, which specifies the resistance distribution in the intramyocardial circulation. Both the normal beating heart and prolonged diastole have been investigated analytically as well as numerically. It is shown that each of these parameters has its own special significance. Calculated pressure-flow relationships and zero-flow pressures for the case of prolonged diastole show a high sensitivity to $$\bar \tau $$ and α.

[1]  R. Bellamy,et al.  Diastolic Coronary Artery Pressure‐Flow Relations in the Dog , 1978, Circulation research.

[2]  R. Mates,et al.  Coronary Pressure‐Flow Relationships: Controversial Issues and Probable Implications , 1985, Circulation research.

[3]  R. Riley,et al.  HEMODYNAMICS OF COLLAPSIBLE VESSELS WITH TONE: THE VASCULAR WATERFALL. , 1963, Journal of applied physiology.

[4]  E. Kirk,et al.  The Effects of the Coronary Capacitance on the Interpretation of Diastolic Pressure‐Flow Relationships , 1982, Circulation research.

[5]  Yasuo Ogasawara,et al.  Functional Characteristics of Intramyocardial Capacitance Vessels during Diastole in the Dog , 1986, Circulation research.

[6]  B. Sayers,et al.  Characterization of the Extravascular Component of Coronary Resistance by Instantaneous Pressure‐Flow Relationships in the Dog , 1979, Circulation research.

[7]  K. Scheel Comments on "determination of coronary collateral flow by a load line analysis" which appeared in circ. res. 50: 663-670, 1982. , 1982, Circulation research.

[8]  S Sideman,et al.  Time-dependent coronary blood flow distribution in left ventricular wall. , 1987, The American journal of physiology.

[9]  J. Spaan Coronary Diastolic Pressure‐Flow Relation and Zero Flow Pressure Explained on the Basis of Intramyocardial Compliance , 1985, Circulation research.

[10]  T. Arts,et al.  Dynamic capacitance of epicardial coronary arteries in vivo. , 1985, Journal of biomechanical engineering.

[11]  N. Westerhof,et al.  Identification of canine coronary resistance and intramyocardial compliance on the basis of the waterfall model , 2006, Annals of Biomedical Engineering.

[12]  J D Laird,et al.  Diastolic‐Systolic Coronary Flow Differences are Caused by Intramyocardial Pump Action in the Anesthetized Dog , 1981, Circulation research.

[13]  F. Hanley,et al.  Regulation of transmural myocardial blood flow. , 1985, Journal of biomechanical engineering.

[14]  R M Nerem,et al.  Epicardial coronary blood flow including the presence of stenoses and aorto-coronary bypasses--II: Experimental comparison and parametric investigations. , 1988, Journal of biomechanical engineering.

[15]  J. Downey,et al.  The Role of Vascular Capacitance in the Coronary Arteries , 1984, Circulation research.

[16]  E S Kirk,et al.  Inhibition of Coronary Blood Flow by a Vascular Waterfall Mechanism , 1975, Circulation research.