Adaptive distance protection of transmission line in presence of SVC

Abstract In this paper, the analytical and simulation results of the application of adaptive distance protection scheme for the transmission line incorporating Static Var Compensator (SVC) connected at the mid-point is presented. The mal-operation of the distance protection for the transmission line with SVC at various locations are studied. The simulation results show the under-reaching and over-reaching is more severe with SVC at mid-point of the transmission line. To mitigate the mal-operation of the distance protection, the adaptive scheme is presented based on recursive simulation study. The simulation result with adaptive scheme is outperformed as compared with the conventional scheme. Electro-magnetic Transient Program (EMTP) simulations on two machine system is used to substantiate the claim.

[1]  Seyed Abbas Taher,et al.  New approach for optimal UPFC placement using hybrid immune algorithm in electric power systems , 2012 .

[2]  A. Ahmed,et al.  New modified first zone algorithm for transmission lines with series compensators , 2012, 2012 IEEE Fifth Power India Conference.

[3]  S. Jamali,et al.  Robustness of distance relay with Mho characteristic against fault resistance , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[4]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[5]  Paul M. Anderson Power System Protection , 1998 .

[6]  Mojtaba Khederzadeh The impact of FACTS device on digital multifunctional protective relays , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[7]  J. K. Hwang,et al.  A complex communication network for distribution automation using a fiber optic network and WLANs , 2012 .

[8]  Babak Mozafari,et al.  Impact of SVC on the protection of transmission lines , 2012 .

[9]  T.S. Sidhu,et al.  Performance Comparison of Distance Protection Schemes for Shunt-FACTS Compensated Transmission Lines , 2007, IEEE Transactions on Power Delivery.

[10]  T.S. Sidhu,et al.  Impact of Shunt-FACTS on Distance Protection of Transmission Lines , 2006, 2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources.

[11]  Babak Mozafari,et al.  Digital distance protection of transmission lines in the presence of SSSC , 2012 .

[12]  A. Ahmed,et al.  Robust distance protection of mid-point shunt compensated transmission line , 2012, 2012 IEEE Fifth Power India Conference.

[13]  T.S. Sidhu,et al.  Performance of distance relays on shunt-FACTS compensated transmission lines , 2005, IEEE Transactions on Power Delivery.