Neutron-induced signal on the single crystal chemical vapor deposition diamond-based neutral particle analyzer.

A diamond-based neutral particle analyzer (DNPA) array composed of single-crystal chemical vapor deposition (sCVD) diamond detectors was installed on the Large Helical Device (LHD) for measuring the helically trapped energetic particles. In high neutron flux experiments, the unwanted neutron-induced pulse counting rate should be estimated using the neutron diagnostics because a diamond detector is sensitive to neutrons as well as energetic neutral particles. In order to evaluate the quantitative neutron-induced pulse counting rate on the DNPA, the response functions of the sCVD diamond detector for mono-energetic neutrons were obtained using accelerator-based D-D and D-7Li neutron sources in Fast Neutron Laboratory (FNL). As a result of the neutron flux estimation by the Monte Carlo N-Particle code at the NPA position in the LHD and the response function obtained in the FNL experiment, the counting rate of the neutron-induced signal was predicted to be 1.1 kcps for the source neutron emission rate of Sn = 1 × 1015 n/s. In the LHD experiment, the neutron-induced signals were observed by closing the gate valve during the plasma discharges. It is found that the counting rates of the neutron-induced signals proportional to Sn reached 1.1 kcps at Sn = 1 × 1015 n/s. As a result of the quantitative estimation of the neutron-induced signals on the DNPA using other neutron measurements, it has become possible to accurately measure energetic neutral particles in the high neutron flux experiment.

[1]  M. Osakabe,et al.  Thermal neutron measurement by single crystal CVD diamond detector applied with the pulse shape discrimination during deuterium plasma experiment in LHD , 2020 .

[2]  M. Isobe,et al.  Fast-ion D alpha diagnostic with 3D-supporting FIDASIM in the Large Helical Device , 2020, Nuclear Fusion.

[3]  M. Kobayashi,et al.  Performance of the newly installed vertical neutron cameras for low neutron yield discharges in the Large Helical Device. , 2020, The Review of scientific instruments.

[4]  M. Osakabe,et al.  Enhancement of an E parallel B type neutral particle analyzer with high time resolution in the Large Helical Device , 2020, Journal of Instrumentation.

[5]  M. Osakabe,et al.  Development of NPA array using single crystal CVD diamond detectors , 2019, Journal of Instrumentation.

[6]  M. Osakabe,et al.  Evaluation of an Energetic Particle Profile Using a Tangential-FIDA Diagnostic in the Large Helical Device , 2019, Plasma and Fusion Research.

[7]  S. Murakami,et al.  Energetic ion confinement studies using comprehensive neutron diagnostics in the Large Helical Device , 2019, Nuclear Fusion.

[8]  M. Osakabe,et al.  Analysis of Energetic Particle Confinement in LHD Using Neutron Measurement and Simulation Codes , 2019, Plasma and Fusion Research.

[9]  S. Murakami,et al.  Fusion neutron production with deuterium neutral beam injection and enhancement of energetic-particle physics study in the large helical device , 2018, Nuclear Fusion.

[10]  Masaki Osakabe,et al.  Neutron Diagnostics in the Large Helical Device , 2018, IEEE Transactions on Plasma Science.

[11]  Takuya Furuta,et al.  Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02 , 2018 .

[12]  T. Nishitani,et al.  Monte Carlo simulation of the neutron measurement for the Large Helical Device deuterium experiments , 2017 .

[13]  A Uritani,et al.  Wide dynamic range neutron flux monitor having fast time response for the Large Helical Device. , 2014, The Review of scientific instruments.

[14]  H. J. Lee,et al.  Design and calibration of a neutral particle analyzer for the KSTAR , 2011 .

[15]  T. Seki,et al.  Pellet charge exchange helium measurement using neutral particle analyzer in large helical device. , 2008, The Review of scientific instruments.

[16]  M. A. Vincenti,et al.  Development of single crystal diamond neutron detectors and test at JET tokamak , 2008 .

[17]  R. Orava,et al.  A novel silicon detector for neutral particle analysis in JET fusion research , 2008 .

[18]  J. Frenje,et al.  Compact multichannel neutral particle analyzer for measurement of energetic charge-exchanged neutrals in Alcator C-Mod , 2006 .

[19]  A. V. Krasilnikov,et al.  Application of natural diamond detector to energetic neutral particle measurements on NSTX , 2003 .

[20]  K. Kawahata,et al.  Charge exchange neutral particle analysis with natural diamond detectors on LHD heliotron , 2001 .

[21]  K. Kawahata,et al.  Development and energy calibration of Si-FNA for LHD fast ion measurement , 2001 .

[22]  A. V. Krasilnikov,et al.  Tokamak Fusion Test Reactor charge exchange atom spectrometry using a natural diamond detector , 1999 .

[23]  Takashi Nakamura,et al.  Development and characterization of real-time personal neutron dosemeter with two silicon detectors , 1998 .

[24]  Naohiro Hirakawa,et al.  Development of monoenergetic neutron calibration fields between 8 keV and 15 MeV , 1996 .

[25]  H. Takeuchi,et al.  Application of silicon surface barrier detector for fast neutral particles , 1985 .

[26]  P. Stott,et al.  A neutral-particle analyser for plasma diagnostics , 1978 .

[27]  Jörg W. Müller Dead-time problems , 1973 .