Conventional detection method of fibrinogen and fibrin degradation products using latex piezoelectric immunoassay.

We developed a conventional immunosensor for fibrinogen and fibrin degradation products (FDP) to combine a quartz crystal microbalance (QCM) with the agglutination reaction of immunized latex beads. FDP induced an immunoreaction due to anti-FDP antibody immobilized latex particles. We successfully measured FDP concentration of in human serum within 10 min by QCM method. The detection range of QCM immunosensor is covered with screening concentration of FDP in serum (<10 microg/ml of FDP). The time course of latex agglutination obtained from QCM immunosensor is synchronized to that of latex photometric immunoassay. SEM was used to observe the surface of QCM that applied FDP serum. The size of latex particles agglutinated on the QCM electrode increased concomitant with FDP concentration. Frequency shift on immunoreaction explains the increased adsorption amount of agglutinated latex on QCM.

[1]  S. Kurosawa,et al.  Latex piezoelectric immunoassay: detection of agglutination of antibody-bearing latex using a piezoelectric quartz crystal. , 1990, Chemical & pharmaceutical bulletin.

[2]  T. Matsumoto,et al.  Determination of FDP in human plasma by a novel latex immunoassay. , 1988, Thrombosis research.

[3]  C P Price,et al.  Immunosensors: technology and opportunities in laboratory medicine. , 1996, Clinical chemistry.

[4]  C. L. Arthur,et al.  Liquid-phase piezoelectric and acoustic transmission studies of interfacial immunochemistry. , 1986, Analytical chemistry.

[5]  I Karube,et al.  A quartz crystal viscosity sensor for monitoring coagulation reaction and its application to a multichannel coagulation detector. , 1991, Biosensors & bioelectronics.

[6]  W. Nieuwenhuizen,et al.  New enzyme immunoassay of fibrin-fibrinogen degradation products in plasma using a monoclonal antibody. , 1987, The Journal of laboratory and clinical medicine.

[7]  N. Yamazoe,et al.  Selective and repeatable detection of human serum albumin by using piezoelectric immunosensor , 1995 .

[8]  Hideo Tanaka,et al.  Conventional diagnosis of C-reactive protein in serum using latex piezoelectric immunoassay , 2001 .

[9]  S. Kurosawa,et al.  Development and Applications of a New Immunoassay Method: Latex Piezoelectric Immunoassay , 1997 .

[10]  M. Donati Assays for Fibrinogen-Fibrin Degradation Products in Biological Fluids: Some Methodological Aspects , 1975, Thrombosis and Haemostasis.

[11]  Garvey Mb,et al.  The detection of fibrinogen-fibrin degradation products by means of a new antibody-coated latex particle. , 1972 .

[12]  W. Nieuwenhuizen,et al.  A Monoclonal Antibody-Based Enzyme Immunoassay for Fibrin Degradation Products in Plasma , 1988, Thrombosis and Haemostasis.

[13]  S. Kurosawa,et al.  Latex piezoelectric immunoassay: analysis of C-reactive protein in human serum , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  M. Mascini,et al.  Surface modifications for the development of piezoimmunosensors. , 1998, Biosensors & bioelectronics.

[15]  Kenji Yokoyama,et al.  Highly sensitive quartz crystal immunosensors for multisample detection of herbicides , 1995 .

[16]  S. Kurosawa,et al.  Detection of antistreptolysin O antibody: application of an initial rate method of latex piezoelectric immunoassay. , 1992, Analytical chemistry.

[17]  R. Abbate,et al.  Relationship between classical FDP test and D-dimer assayed both by latex agglutination and ELISA. , 1990, Thrombosis research.

[18]  Kato Kanefusa,et al.  Measurement of fibrinogen degradation products by a sandwich enzyme immunoassay technique. , 1980 .

[19]  N. Kamo,et al.  Improvement of latex piezoelectric immunoassay: Detection of rheumatoid factor. , 1994, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[20]  I Lundström,et al.  Comparison of surface plasmon resonance and quartz crystal microbalance in the study of whole blood and plasma coagulation. , 2000, Biosensors & bioelectronics.

[21]  I. Karube,et al.  Quartz-crystal gelation detector for the determination of fibrinogen concentration , 1989 .

[22]  J. T. Horan,et al.  Fibrin degradation products, fibrin monomer and soluble fibrin in disseminated intravascular coagulation. , 2001, Seminars in thrombosis and hemostasis.

[23]  S. Kurosawa,et al.  Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed. , 1993, Analytical chemistry.

[24]  E Tamiya,et al.  Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins. , 1987, Analytical chemistry.