Ultrasonic trapping in capillaries for trace-amount biomedical analysis

A longitudinal hemispherical standing-wave ultrasonic trap for size-selective separation of microspheres in small-diameter capillaries is described. The trap utilizes the competition between acoustic radiation forces and viscous drag forces on spheres suspended in a liquid inside 20–75-μm-diam fused silica capillaries. Experiments performed on 3.0- and 4.7-μm-diam latex spheres demonstrate the principles of trapping and verify the theoretically calculated size-dependent forces on the spheres. The spheres are detected by the use of laser-induced fluorescence. The goal is to use the trap for separation and ultrahigh-sensitivity detection of trace amounts of proteins and other macromolecules containing two antigenic sites, by binding the target molecule with high specificity to antibody-coated latex spheres.

[1]  T Laurell,et al.  Sample enrichment in a single levitated droplet for capillary electrophoresis. , 1998, Journal of chromatography. B, Biomedical sciences and applications.

[2]  Lawrence A. Crum,et al.  Acoustic Force on a Liquid Droplet in an Acoustic Stationary Wave , 1971 .

[3]  J. Hawkes,et al.  Filtration of bacteria and yeast by ultrasound‐enhanced sedimentation , 1997, Journal of applied microbiology.

[4]  Ica Manas-Zloczower,et al.  Fractionation of mixed particulate solids according to compressibility using ultrasonic standing wave fields , 1995 .

[5]  Michael W. Berns,et al.  OPTICAL TRAPPING AND FLUORESCENCE DETECTION IN LAMINAR-FLOW STREAMS , 1995 .

[6]  A. R. Selfridge,et al.  Approximate Material Properties in Isotropic Materials , 1985, IEEE Transactions on Sonics and Ultrasonics.

[7]  Robert E. Apfel,et al.  Extension of acoustic levitation to include the study of micron‐size particles in a more compressible host liquid , 1982 .

[8]  M A Sobanski,et al.  Ultrasonic enhancement of coated particle agglutination immunoassays: influence of particle density and compressibility. , 1999, Ultrasound in medicine & biology.

[9]  W. Coakley,et al.  Ultrasonic separations in analytical biotechnology. , 1997, Trends in biotechnology.

[10]  Hans M. Hertz,et al.  Standing-wave Acoustic Trap For Nonintrusive Positioning of Microparticles , 1995 .

[11]  Shin-ichiro Umemura,et al.  Particle separation using acoustic radiation force and elecrostatic force , 1996 .

[12]  G. Batchelor,et al.  Brownian diffusion of particles with hydrodynamic interaction , 1976, Journal of Fluid Mechanics.

[13]  E. Brandt Levitation in Physics , 1989, Science.

[14]  T Kaneta,et al.  Application of optical chromatography to immunoassay. , 1997, Analytical chemistry.

[15]  J. Sweedler,et al.  Wavelength-resolved fluorescence detection in capillary electrophoresis. , 1995, Analytical chemistry.

[16]  E. Yeung,et al.  Laser-based particle-counting microimmunoassay for the analysis of single human erythrocytes. , 1994, Analytical chemistry.

[17]  J. Johansson,et al.  Real-Time Imaging through Optical Fiber Array-Assisted Laser-Induced Fluorescence of Capillary Electrophoretic Enantiomer Separations. , 1999, Analytical chemistry.

[18]  Donald L. Feke,et al.  Methodology for fractionating suspended particles using ultrasonic standing wave and divided flow fields , 1995 .

[19]  H. Issaq A decade of capillary electrophoresis , 2000, Electrophoresis.