Advanced LIGO squeezer platform for backscattered light and optical loss reduction

The Advanced LIGO gravitational-wave detectors are limited by optical quantum noise in most of their detection band. To overcome this limit, squeezed vacuum states have been injected into the Advanced LIGO detectors during the third observing run (O3), leading to an increase of their detection rate by about 40% to 50%. Here we present a key element of LIGO’s squeezed vacuum source: the seismic isolation platform that houses core components placed in ultra-high vacuum. This paper describes the architecture of the isolation platform as well as the active control system, tuned to minimize backscattered light that otherwise deteriorates the sensitivity of the detectors. This architecture permits fewer optical Faraday isolators in the optical path of the squeezing system, minimizing optical losses to maximize the quantum noise improvement. The system reliably operated throughout LIGO’s O3 with no evidence of noise from backscattered light. The innovative architecture of this platform makes it ideal for straightforward reshaping and adaptation to other gravitational-wave detector subsystems and low-noise optical instrumentation.

[1]  R. Roark,et al.  Roark's Formulas for Stress and Strain , 2020 .

[2]  J. R. Palamos,et al.  Quantum-Enhanced Advanced LIGO Detectors in the Era of Gravitational-Wave Astronomy. , 2019, Physical review letters.

[3]  S. Aston Optical read-out techniques for the control of test-masses in gravitational wave observatories , 2016 .

[4]  P. Sarin,et al.  Seismic isolation of Advanced LIGO: Review of strategy, instrumentation and performance , 2015, 1502.06300.

[5]  M. S. Shahriar,et al.  Characterization of the LIGO detectors during their sixth science run , 2014, 1410.7764.

[6]  N. Mavalvala,et al.  Squeezed light for advanced gravitational wave detectors and beyond. , 2014, Optics express.

[7]  Michael Hillard,et al.  Advanced LIGO two-stage twelve-axis vibration isolation and positioning platform. Part 1: Design and production overview , 2014, 1407.6377.

[8]  M. Batista Analytical treatment of equilibrium configurations of cantilever under terminal loads using Jacobi elliptical functions , 2014 .

[9]  J. Herder,et al.  Large deflection analysis of cantilever beam under end point and distributed loads , 2014 .

[10]  M. Evans,et al.  Balanced homodyne readout for quantum limited gravitational wave detectors. , 2014, Optics express.

[11]  A. Khalaidovski,et al.  Impact of backscattered light in a squeezing-enhanced interferometric gravitational-wave detector , 2013, 1307.8176.

[12]  Derek K. Jones,et al.  Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light , 2013, Nature Photonics.

[13]  T. Hayler,et al.  Update on quadruple suspension design for Advanced LIGO , 2012 .

[14]  N. Lockerbie,et al.  Sensors and actuators for the Advanced LIGO mirror suspensions , 2012, 1205.5643.

[15]  Peter Fritschel,et al.  Impact of upconverted scattered light on advanced interferometric gravitational wave detectors. , 2012, Optics express.

[16]  D. McClelland,et al.  Tip-tilt mirror suspension: beam steering for advanced laser interferometer gravitational wave observatory sensing and control signals. , 2011, The Review of scientific instruments.

[17]  Andrew G. Alleyne,et al.  Iterative learning control , 2010 .

[18]  D. Coyne LIGO Vacuum Compatible Materials List , 2004 .

[19]  L. Pinard,et al.  Scattered light noise in gravitational wave interferometric detectors: A statistical approach , 1997 .

[20]  Brisson,et al.  Scattered light noise in gravitational wave interferometric detectors: Coherent effects. , 1996, Physical review. D, Particles and fields.

[21]  Peter R. Saulson,et al.  Brownian motion of a mass suspended by an anelastic wire , 1994 .

[22]  A. Slocum,et al.  Precision Machine Design , 1992 .

[23]  Gene F. Franklin,et al.  Feedback Control of Dynamic Systems , 1986 .

[24]  S. G. Barton,et al.  The derivation of creep properties from stress relaxation in steels and non-ferrous metals , 1981 .

[25]  C. Caves Quantum Mechanical Noise in an Interferometer , 1981 .