Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Photon counting detectors (PCDs) with energy discrimination capabilities have been developed for medical x-ray computed tomography (CT) and x-ray (XR) imaging. Using detection mechanisms that are completely different from the current energy integrating detectors and measuring the material information of the object to be imaged, these PCDs have the potential not only to improve the current CT and XR images, such as dose reduction, but also to open revolutionary novel applications such as molecular CT and XR imaging. The performance of PCDs is not flawless, however, and it seems extremely challenging to develop PCDs with close to ideal characteristics. In this paper, the authors offer our vision for the future of PCD-CT and PCD-XR with the review of the current status and the prediction of (1) detector technologies, (2) imaging technologies, (3) system technologies, and (4) potential clinical benefits with PCDs.

[1]  R. W. Fink,et al.  X-Ray Fluorescence Yields, Auger, and Coster-Kronig Transition Probabilities , 1972 .

[2]  R. K. Swank Absorption and noise in x‐ray phosphors , 1973 .

[3]  M. Martini,et al.  Polarization Phenomena in CdTe: Preliminary Results , 1973 .

[4]  G. Entine,et al.  Time-dependent polarization of CdTe gamma-ray detectors , 1974 .

[5]  Robin P. Gardner,et al.  Prediction of the pulse-height spectral distortion caused by the peak pile-up effect , 1976 .

[6]  P. Siffert,et al.  Polarization in Cadmium Telluride Nuclear Radiation Detectors , 1976, IEEE Transactions on Nuclear Science.

[7]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[8]  Robin P. Gardner,et al.  A generalized method for correcting pulse-height spectra for the peak pile-up effect due to double sum pulses: Part I. Predicting spectral distortion for arbitrary pulse shapes , 1977 .

[9]  P. Joseph,et al.  Noise considerations in dual energy CT scanning. , 1979, Medical physics.

[10]  G. Knoll Radiation detection and measurement , 1979 .

[11]  J. Iwanczyk,et al.  X-ray fluorescence escape peaks in gamma-ray spectra detected by CdTe detectors , 1979 .

[12]  J. Kemmer,et al.  A multisegment annular Si-detector system for RBS analysis , 1988 .

[13]  K. Hodgson,et al.  Simulation and modelling of a new silicon X-ray drift detector design for synchrotron radiation applications , 1996 .

[14]  Bradley E. Patt,et al.  New gamma-ray detector structures for electron only charge carrier collection utilizing high-Z compound semiconductors , 1996 .

[15]  J. Eskin,et al.  Semiconductor gamma-ray detectors for nuclear medicine , 1997 .

[16]  E. Beuville,et al.  High resolution X-ray imaging using a silicon strip detector , 1997 .

[17]  S A Wickline,et al.  Magnetic resonance contrast enhancement of neovasculature with alpha(v)beta(3)-targeted nanoparticles. , 2000, Magnetic resonance in medicine.

[18]  C A Kelsey,et al.  CT scanning: patterns of use and dose , 2000, Journal of radiological protection : official journal of the Society for Radiological Protection.

[19]  Stasia A. Anderson,et al.  Magnetic resonance contrast enhancement of neovasculature with αvβ3‐targeted nanoparticles , 2000 .

[20]  J A Fessler,et al.  Mean and variance of single photon counting with deadtime. , 2000, Physics in medicine and biology.

[21]  J. Hsieh,et al.  An iterative approach to the beam hardening correction in cone beam CT. , 2000, Medical physics.

[22]  K. Bae,et al.  Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. , 2000, Medical physics.

[23]  S A Wickline,et al.  Novel MRI Contrast Agent for Molecular Imaging of Fibrin: Implications for Detecting Vulnerable Plaques , 2001, Circulation.

[24]  Jeffrey A. Fessler,et al.  Mean and variance of coincidence counting with deadtime , 2002 .

[25]  Satoshi Miyajima,et al.  CdZnTe detector in diagnostic x-ray spectroscopy. , 2002, Medical physics.

[26]  Shelton D Caruthers,et al.  Molecular imaging of angiogenesis in nascent Vx-2 rabbit tumors using a novel alpha(nu)beta3-targeted nanoparticle and 1.5 tesla magnetic resonance imaging. , 2003, Cancer research.

[27]  A. Kassner,et al.  Molecular Imaging of Angiogenesis in Nascent Vx-2 Rabbit Tumors Using a Novel ανβ3-targeted Nanoparticle and 1.5 Tesla Magnetic Resonance Imaging , 2003 .

[28]  Ralph Weissleder,et al.  Seeing Within: Molecular Imaging of the Cardiovascular System , 2004, Circulation research.

[29]  G. Montemont,et al.  Simulation and experimental results on monolithic CdZnTe gamma-ray detectors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[30]  T. Tumer,et al.  Multi-energy X-ray imaging with linear CZT pixel arrays and integrated electronics , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[31]  J. Hsieh,et al.  A novel reconstruction algorithm to extend the CT scan field-of-view. , 2004, Medical physics.

[32]  Larry Partain,et al.  Dark current, sensitivity, and image lag comparison of mercuric iodide and lead iodide x-ray imagers , 2004, SPIE Optics + Photonics.

[33]  Y. Shirayanagi,et al.  X-ray color scanner with multiple energy differentiate capability , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[34]  Yasuhiro Tomita,et al.  X-ray color scanner with multiple energy discrimination capability , 2005, SPIE Optics + Photonics.

[35]  G. Montemont,et al.  Simulation and experimental results on monolithic CdZnTe gamma-ray detectors , 2005, IEEE Transactions on Nuclear Science.

[36]  S. Molloi,et al.  Photon counting computed tomography: concept and initial results. , 2005, Medical physics.

[37]  Shelton D Caruthers,et al.  Molecular imaging of human thrombus with computed tomography. , 2005, Academic radiology.

[38]  Grace Hu,et al.  Molecular MR imaging of melanoma angiogenesis with ανβ3‐targeted paramagnetic nanoparticles , 2005, Magnetic resonance in medicine.

[39]  Himanshu P. Shukla,et al.  Molecular Imaging of Human Thrombus with Computed Tomography , 2005 .

[40]  Polad M Shikhaliev,et al.  Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study , 2005, Physics in medicine and biology.

[41]  C. Herrmann,et al.  Counting and integrating readout for direct conversion X-ray imaging concept, realization and first prototype measurements , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[42]  N. P. Barradas,et al.  Accurate calculation of pileup effects in PIXE spectra from first principles , 2006 .

[43]  Jan Grimm,et al.  An X-ray computed tomography imaging agent based on long-circulating bismuth sulphide nanoparticles , 2006, Nature materials.

[44]  C. Granja,et al.  Compact System for High Resolution X-ray Transmission Radiography, In-line Phase Enhanced Imaging and Micro CT of Biological Samples , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[45]  E. Nygard,et al.  Guard ring elimination in CdTe and CdZnTe detectors , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[46]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[47]  Alexander A Zamyatin,et al.  Extension of the reconstruction field of view and truncation correction using sinogram decomposition. , 2007, Medical physics.

[48]  M. Campbell,et al.  The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance , 2006, IEEE Transactions on Nuclear Science.

[49]  Björn Cederström,et al.  Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors. , 2007, Medical physics.

[50]  D. Bale,et al.  Ultra High Flux 2-D CdZnTe Monolithic Detector Arrays for X-Ray Imaging Applications , 2007, IEEE Transactions on Nuclear Science.

[51]  Small‐scale in vivo imaging of soft tissues by radioscopy using single X‐ray photon counting , 2007, Journal of microscopy.

[52]  Zahi A Fayad,et al.  Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography , 2007, Nature Medicine.

[53]  M. Defrise,et al.  Tiny a priori knowledge solves the interior problem , 2007 .

[54]  P Guerra,et al.  Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system , 2008, Physics in medicine and biology.

[55]  M. Drangova,et al.  Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition. , 2008, Medical physics.

[56]  M. Defrise,et al.  Solving the interior problem of computed tomography using a priori knowledge , 2008, Inverse problems.

[57]  A. J. Bell,et al.  Bio-medical X-ray imaging with spectroscopic pixel detectors , 2008 .

[58]  Hengyong Yu,et al.  Interior Reconstruction Using the Truncated Hilbert Transform via Singular Value Decomposition. , 2008, Journal of X-ray science and technology.

[59]  J. Schlomka,et al.  Multienergy photon-counting K-edge imaging: potential for improved luminal depiction in vascular imaging. , 2008, Radiology.

[60]  P. Shikhaliev Energy-resolved computed tomography: first experimental results , 2008, Physics in medicine and biology.

[61]  W P Segars,et al.  Realistic CT simulation using the 4D XCAT phantom. , 2008, Medical physics.

[62]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[63]  S. Caruthers,et al.  Ligand-directed nanobialys as theranostic agent for drug delivery and manganese-based magnetic resonance imaging of vascular targets. , 2008, Journal of the American Chemical Society.

[64]  J. Iwanczyk,et al.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging , 2007, IEEE Transactions on Nuclear Science.

[65]  J. Jakubek,et al.  Real-time in-vivo m-imaging with Medipix 2 , 2009 .

[66]  Cynthia H McCollough,et al.  Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT. , 2009, Medical physics.

[67]  Thilo Michel,et al.  Contrast agent recognition in small animal CT using the Medipix2 detector , 2009 .

[68]  Hengyong Yu,et al.  Compressed sensing based interior tomography , 2009, Physics in medicine and biology.

[69]  Cheng Xu,et al.  Photon-counting CT with silicon detectors: feasibility for pediatric imaging , 2009, Medical Imaging.

[70]  M. Jiang,et al.  Supplemental analysis on compressed sensing based interior tomography. , 2009, Physics in medicine and biology.

[71]  Samuel A Wickline,et al.  Detecting vascular biosignatures with a colloidal, radio-opaque polymeric nanoparticle. , 2009, Journal of the American Chemical Society.

[72]  Taly Gilat Schmidt,et al.  Optimal "image-based" weighting for energy-resolved CT. , 2009, Medical physics.

[73]  J. Jakubek,et al.  Real-time in-vivo -imaging with Medipix2 , 2009 .

[74]  Jiang Hsieh,et al.  Beam hardening correction in CT myocardial perfusion measurement , 2009, Physics in medicine and biology.

[75]  J. Iwanczyk,et al.  Polycrystalline Mercuric Iodide Films on CMOS Readout Arrays , 2009, IEEE Transactions on Nuclear Science.

[76]  Katsuyuki Taguchi,et al.  Characterization of a novel photon counting detector for clinical CT: count rate, energy resolution, and noise performance , 2009, Medical Imaging.

[77]  Hengyong Yu,et al.  A scheme for multisource interior tomography. , 2009, Medical physics.

[78]  Marc Kachelrieß,et al.  Dynamic Iterative Beam Hardening Correction (DIBHC) in Myocardial Perfusion Imaging Using Contrast-Enhanced Computed Tomography , 2010, Investigative radiology.

[79]  Jesse Tanguay,et al.  The role of x-ray Swank factor in energy-resolving photon-counting imaging. , 2010, Medical physics.

[80]  Cheng Xu,et al.  Simulation study of an energy sensitive photon counting silicon strip detector for computed tomography: identifying strengths and weaknesses and developing work-arounds , 2010, Medical Imaging.

[81]  Christoph Herrmann,et al.  ChromAIX: a high-rate energy-resolving photon-counting ASIC for spectal computed tomography , 2010, Medical Imaging.

[82]  Katsuyuki Taguchi,et al.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors , 2010, Medical Imaging.

[83]  Erik Fredenberg,et al.  Contrast-enhanced spectral mammography with a photon-counting detector. , 2010, Medical physics.

[84]  M. Danielsson,et al.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study , 2010, Physics in medicine and biology.

[85]  Katsuyuki Taguchi,et al.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors. , 2010 .

[86]  Cheng Xu,et al.  Design considerations to overcome cross talk in a photon counting silicon strip detector for computed tomography , 2010 .

[87]  Erik Fredenberg,et al.  Energy resolution of a photon-counting silicon strip detector , 2010, 2101.07789.

[88]  Axel Thran,et al.  Note: This Copy Is for Your Personal, Non-commercial Use Only. to Order Presentation-ready Copies for Distribution to Your Colleagues or Clients, Contact Us at Www.rsna.org/rsnarights. Atherosclerotic Plaque Composition: Analysis with Multicolor Ct and Targeted Gold Nanoparticles 1 Materials and Met , 2022 .

[89]  J. Schlomka,et al.  Computed tomography in color: NanoK-enhanced spectral CT molecular imaging. , 2010, Angewandte Chemie.

[90]  Polad M Shikhaliev The upper limits of the SNR in radiography and CT with polyenergetic x-rays. , 2010, Physics in medicine and biology.

[91]  Edgar Kraft,et al.  A research prototype system for quantum-counting clinical CT , 2010, Medical Imaging.

[92]  Taly Gilat Schmidt,et al.  CT energy weighting in the presence of scatter and limited energy resolution. , 2010, Medical physics.

[93]  Katsuyuki Taguchi,et al.  Statistical Projection Completion in X-ray CT Using Consistency Conditions , 2010, IEEE Transactions on Medical Imaging.

[94]  Adam S Wang,et al.  Pulse pileup statistics for energy discriminating photon counting x-ray detectors. , 2011, Medical physics.

[95]  Marios E Myronakis,et al.  Monte Carlo investigation of charge-transport effects on energy resolution and detection efficiency of pixelated CZT detectors for SPECT/PET applications. , 2010, Medical physics.

[96]  Cheng Xu,et al.  Evaluation of Energy Loss and Charge Sharing in Cadmium Telluride Detectors for Photon-Counting Computed Tomography , 2011, IEEE Transactions on Nuclear Science.

[97]  William C. Barber,et al.  Energy-resolved photon-counting x-ray imaging arrays for clinical K-edge CT , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[98]  Daniel Turecek,et al.  Characterization of Medipix3 With Synchrotron Radiation , 2011, IEEE Transactions on Nuclear Science.

[99]  Katsuyuki Taguchi,et al.  XCAT/DRASIM: a realistic CT/human-model simulation package , 2011, Medical Imaging.

[100]  Cheng Xu,et al.  Performance characterization of a silicon strip detector for spectral computed tomography utilizing a laser testing system , 2011, Medical Imaging.

[101]  Vipul R Sheth,et al.  A self-calibrating PARACEST MRI contrast agent that detects esterase enzyme activity. , 2010, Contrast media & molecular imaging.

[102]  Taly Gilat Schmidt,et al.  Region-of-interest material decomposition from truncated energy-resolved CT. , 2011, Medical physics.

[103]  Christoph Herrmann,et al.  A comparative study of a dual-energy-like imaging technique based on counting-integrating readout. , 2011, Medical physics.

[104]  Katsuyuki Taguchi,et al.  Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion. , 2011, Medical physics.

[105]  C. Mistretta,et al.  Noise reduction in spectral CT: reducing dose and breaking the trade-off between image noise and energy bin selection. , 2011, Medical physics.

[106]  Karl Stierstorfer,et al.  Quantum-counting CT in the regime of count-rate paralysis: introduction of the pile-up trigger method , 2011, Medical Imaging.

[107]  Katsuyuki Taguchi,et al.  Modeling the performance of a photon counting x-ray detector for CT: energy response and pulse pileup effects. , 2011, Medical physics.

[108]  Axel Thran,et al.  Sensitivity of Photon-Counting Based ${\rm K}$-Edge Imaging in X-ray Computed Tomography , 2011, IEEE Transactions on Medical Imaging.

[109]  C. Svensson,et al.  Preliminary evaluation of a silicon strip detector for photon-counting spectral CT , 2012 .

[110]  Edgar Kraft,et al.  Experimental evaluation of the pile-up trigger method in a revised quantum-counting CT detector , 2012, Medical Imaging.

[111]  Mats Danielsson,et al.  Performance evaluation of a sub-millimetre spectrally resolved CT system on high- and low-frequency imaging tasks: a simulation. , 2012, Physics in medicine and biology.

[112]  Katsuyuki Taguchi,et al.  Spectral response compensation for photon-counting clinical x-ray CT using sinogram restoration , 2012, Medical Imaging.

[113]  Sabee Molloi,et al.  Image-based spectral distortion correction for photon-counting x-ray detectors. , 2012, Medical physics.

[114]  Katsuyuki Taguchi,et al.  Compensation of nonlinear distortions in photon-counting spectral CT: deadtime loss, spectral response, and beam hardening effects , 2012, Medical Imaging.

[115]  Katsuyuki Taguchi,et al.  Pulse pileup statistics for energy sensitive photon counting detectors with pulse height analysis , 2012, Medical Imaging.

[116]  Thilo Hannemann,et al.  First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT , 2012, Medical Imaging.

[117]  Franco Rupcich,et al.  Experimental study of optimal energy weighting in energy-resolved CT using a CZT detector , 2013, Medical Imaging.

[118]  Norbert J Pelc,et al.  The feasibility of a piecewise-linear dynamic bowtie filter. , 2013, Medical physics.

[119]  C. Svensson,et al.  Evaluation of a Second-Generation Ultra-Fast Energy-Resolved ASIC for Photon-Counting Spectral CT , 2013, IEEE Transactions on Nuclear Science.

[120]  Michael Campbell,et al.  Charge Summing in Spectroscopic X-Ray Detectors With High-Z Sensors , 2013, IEEE Transactions on Nuclear Science.

[121]  Cheng Xu,et al.  Energy resolution of a segmented silicon strip detector for photon-counting spectral CT , 2013 .

[122]  Katsuyuki Taguchi,et al.  Modeling photon-counting detectors for x-ray CT: spectral response and pulse-pileup effects and evaluation using real data , 2013, Medical Imaging.

[123]  Katsuyuki Taguchi,et al.  A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT. , 2014, Medical physics.