Highly Sensitive Electrochemical Sensor for the Determination of 8-Hydroxy-2′-deoxyguanosine Incorporating SWCNTs-Nafion Composite Film

8-Hydroxy-2′-deoxyguanosine (8-OHdG) is a typical biomarker of oxidative DNA damage and has attracted much attention in recent years since the level of 8-OHdG in body fluids is typically associated with various diseases. In this work, a simple and highly sensitive electrochemical sensor for the determination of 8-OHdG was fabricated incorporating single wall carbon nanotubes- (SWCNTs-) Nafion composite film coated on glassy carbon electrode. Nafion was chosen as an optimal adhesive agent from a series of adhesive agents and acted as a binder, enrichment, and exclusion film. Due to the strong cation-exchange ability of Nafion and the outstanding electronic properties of SWCNTs, the prepared SWCNTs-Nafion film can strongly enhance the electrochemical response to oxidation of 8-OHdG and efficiently alleviate the interferences from uric acid and ascorbic acid. The oxidation peak currents are linear with the concentration of 8-OHdG in the range of 0.03 to 1.25 μM with a detection limit of 8.0 nM (S/N = 3). This work demonstrates that SWCNTs-Nafion film can improve the sensitivity, selectivity, reproducibility, and stability, making it an ideal candidate for electrochemical detection of 8-OHdG.

[1]  Brian Crow,et al.  A simple and cost effective method for the quantification of 8-hydroxy-2'-deoxyguanosine from urine using liquid chromatography tandem mass spectrometry. , 2008, Biomedical chromatography : BMC.

[2]  Xuena Zhu,et al.  Biosensing approaches for rapid genotoxicity and cytotoxicity assays upon nanomaterial exposure. , 2013, Small.

[3]  Shengshui Hu,et al.  Electrochemical Study and Selective Determination of Dopamine at a Multi-Wall Carbon Nanotube-Nafion Film Coated Glassy Carbon Electrode , 2004 .

[4]  Caiying Wu,et al.  Determination of urinary oxidative DNA damage marker 8-hydroxy-2'-deoxyguanosine and the association with cigarette smoking. , 2004, Talanta.

[5]  G. Rivas,et al.  Determinatiom of 8‐Hydroxy 2′‐Deoxyguanosine Using Electrodes Modified with a Dispersion of Carbon Nanotubes in Polyethylenimine , 2011 .

[6]  Joseph Wang Carbon‐Nanotube Based Electrochemical Biosensors: A Review , 2005 .

[7]  Hiroshi Kasai,et al.  Effect of age, smoking and other lifestyle factors on urinary 7‐methylguanine and 8‐hydroxydeoxyguanosine , 2009, Cancer science.

[8]  Alejandro Alatorre,et al.  Amperometric Detection and Quantification of 8‐Hydroxy‐2′‐deoxyguanosine (8‐OHdG) Using Dendrimer Modified Electrodes , 2008 .

[9]  Mei-Ling Cheng,et al.  Increased oxidative damage in peripheral blood correlates with severity of Parkinson's disease , 2009, Neurobiology of Disease.

[10]  S. Oikawa,et al.  Oxidative DNA damage by hyperglycemia‐related aldehydes and its marked enhancement by hydrogen peroxide , 2003, FEBS letters.

[11]  P. Ajayan Nanotubes from Carbon. , 1999, Chemical reviews.

[12]  Filip Braet,et al.  Carbon nanotubes for biological and biomedical applications , 2007 .

[13]  Zhennan Gu,et al.  Structure modification of single-wall carbon nanotubes , 2000 .

[14]  Naoyuki Kitamura,et al.  Measurement of urinary 8-oxo-7,8-dihydro-2-deoxyguanosine in a novel point-of-care testing device to assess oxidative stress in children. , 2012, Clinica chimica acta; international journal of clinical chemistry.

[15]  许国旺,et al.  Determination of urinary 8-hydroxy-2′-deoxyguanosine by two approaches—capillary electrophoresis and GC/MS: An assay for in vivo oxidative DNA damage in cancer patients , 2005 .

[16]  Hiroshi Kasai,et al.  Analysis of 8-hydroxy-2'-deoxyguanosine in urine using high-performance liquid chromatography-electrospray tandem mass spectrometry. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[17]  Qiang Zhao,et al.  Electrochemical sensors based on carbon nanotubes , 2002 .

[18]  Silvia H.P. Serrano,et al.  Electrochemical Oxidation of 8-Oxoguanine , 2000 .

[19]  D. Jed Harrison,et al.  Permeability of glucose and other neutral species through recast perfluorosulfonated ionomer films , 1992 .

[20]  J. Lunec,et al.  Evidence of oligonucleotides containing 8-hydroxy-2'-deoxyguanosine in human urine. , 2007, Free radical biology & medicine.

[21]  Kenji Yokoyama,et al.  Development of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) measurement method combined with SPE. , 2011, Journal of chromatographic science.

[22]  R. R. Moore,et al.  Basal plane pyrolytic graphite modified electrodes: comparison of carbon nanotubes and graphite powder as electrocatalysts. , 2004, Analytical chemistry.

[23]  Wenli Li,et al.  Capillary electrophoretic determination of DNA damage markers: content of 8-hydroxy-2'-deoxyguanosine and 8-nitroguanine in urine. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[24]  Isabel Rebelo,et al.  Electrochemical determination of 8-oxoguanine in the presence of uric acid. , 2004, Bioelectrochemistry.

[25]  James F. Rusling,et al.  Carbon Nanotubes for Electronic and Electrochemical Detection of Biomolecules , 2007, Advanced materials.

[26]  J. Tkáč,et al.  Dispersion of single walled. carbon nanotubes. Comparison of different dispersing strategies for preparation of modified electrodes toward hydrogen peroxide detection , 2006 .

[27]  Yasuto Itoyama,et al.  Systemic Increase of Oxidative Nucleic Acid Damage in Parkinson's Disease and Multiple System Atrophy , 2002, Neurobiology of Disease.

[28]  Kenji Yokoyama,et al.  Determination of human serum 8-hydroxy-2'-deoxyguanosine (8-OHdG) by HPLC-ECD combined with solid phase extraction (SPE). , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[29]  Shoko Kawanami,et al.  Life Style and Urinary 8‐Hydroxydeoxyguanosine, a Marker of Oxidative DNA Damage: Effects of Exercise, Working Conditions, Meat Intake, Body Mass Index, and Smoking , 2001, Japanese journal of cancer research : Gann.

[30]  Yuehe Lin,et al.  Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors. , 2003, Journal of the American Chemical Society.

[31]  Chen-Zhong Li,et al.  Assessment of oxidative DNA damage and repair at single cellular level via real-time monitoring of 8-OHdG biomarker. , 2010, Biosensors & bioelectronics.

[32]  Ying Liu,et al.  Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in Nafion-RTIL composite film , 2007 .

[33]  Shengshui Hu,et al.  Carbon Nanotube-Based Electrochemical Sensors: Principles and Applications in Biomedical Systems , 2009, J. Sensors.

[34]  Wojtek Wlodarski,et al.  Nanomaterials for Chemical Sensing Technologies , 2009, J. Sensors.

[35]  H E Poulsen,et al.  Measurement of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA and human urine by high performance liquid chromatography-electrospray tandem mass spectrometry. , 2001, Free radical biology & medicine.

[36]  Jing Li,et al.  High-sensitivity determination of lead and cadmium based on the Nafion-graphene composite film. , 2009, Analytica chimica acta.

[37]  H. Kasai,et al.  Analysis of a form of oxidative DNA damage, 8-hydroxy-2'-deoxyguanosine, as a marker of cellular oxidative stress during carcinogenesis. , 1997, Mutation research.

[38]  Eva Samcová,et al.  Electrochemical Oxidation of 8-Oxo-2′-Deoxyguanosine on Glassy Carbon, Gold, Platinum and Tin(IV) Oxide Electrodes , 2003 .

[39]  Wen-Li Jia,et al.  Electrochemical performance of 8-hydroxy-2'-deoxyguanosine and its detection at poly(3-methylthiophene) modified glassy carbon electrode. , 2007, Biosensors & bioelectronics.

[40]  Yuehe Lin,et al.  Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes , 2002 .

[41]  A. Valavanidis,et al.  8-hydroxy-2′ -deoxyguanosine (8-OHdG): A Critical Biomarker of Oxidative Stress and Carcinogenesis , 2009, Journal of environmental science and health. Part C, Environmental carcinogenesis & ecotoxicology reviews.

[42]  Takeshi Matsumura,et al.  Evaluation of urinary 8-hydroxydeoxy-guanosine as a novel biomarker of macrovascular complications in type 2 diabetes. , 2003, Diabetes care.

[43]  Liping Jia,et al.  Electrochemical reduction synthesis of graphene/Nafion nanocomposite film and its performance on the detection of 8-hydroxy-2′-deoxyguanosine in the presence of uric acid , 2013 .

[44]  Choon Nam Ong,et al.  A high-throughput and sensitive methodology for the quantification of urinary 8-hydroxy-2'-deoxyguanosine: measurement with gas chromatography-mass spectrometry after single solid-phase extraction. , 2004, The Biochemical journal.

[45]  Guobin Zhou,et al.  Fast Quantification of Salivary 8-Hydroxy-2′-deoxyguanosine as DNA Damage Biomarker Using CE with Electrochemical Detection , 2014, Chromatographia.

[46]  Behzad Rezaei,et al.  An electrochemical sensor based on multiwall carbon nanotubes and molecular imprinting strategy for warfarin recognition and determination , 2014 .

[47]  Li Zhang,et al.  Myoglobin on multi-walled carbon nanotubes modified electrode: direct electrochemistry and electrocatalysis , 2003 .

[48]  E. Culea,et al.  Structural and electrochemical investigations of the electrodes obtained by recycling of lead acid batteries , 2016 .

[49]  Z. Gu,et al.  Investigation of the electrochemical and electrocatalytic behavior of single-wall carbon nanotube film on a glassy carbon electrode. , 2001, Analytical chemistry.

[50]  R. Olinski,et al.  8-Oxo-2'-deoxyguanosine level in lymphocytes DNA of cancer patients undergoing radiotherapy. , 1996, Cancer letters.

[51]  P. Chang,et al.  Urinary 8-OHdG: a marker of oxidative stress to DNA and a risk factor for cancer, atherosclerosis and diabetics. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[52]  Zhennan Gu,et al.  Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes. , 2002, Analytical chemistry.