Effects of echo‐optimization of left ventricular assist devices on functional capacity, a randomized controlled trial

After the implantation of a left ventricular assist device (LVAD), many patients continue to experience exercise intolerance. VAFRACT trial evaluates the additional benefit of LVAD echo‐guided optimization (EO) on functional capacity (FC), measured by cardiopulmonary exercise test (CPET), and quality of life (QoL).

[1]  G. MacGowan,et al.  The role of exercise hemodynamics in assessing patients with chronic heart failure and left ventricular assist devices , 2019, Expert review of medical devices.

[2]  J. Cowger,et al.  Third Annual Report From the ISHLT Mechanically Assisted Circulatory Support Registry: A comparison of centrifugal and axial continuous-flow left ventricular assist devices. , 2019, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[3]  G. Gerosa,et al.  Comprehensive effects of left ventricular assist device speed changes on alveolar gas exchange, sleep ventilatory pattern, and exercise performance. , 2018, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  G. Gerosa,et al.  Lvad pump speed increase is associated with increased peak exercise cardiac output and vo2, postponed anaerobic threshold and improved ventilatory efficiency. , 2017, International journal of cardiology.

[5]  Gianfranco Ferrari,et al.  Exercise capacity in ventricular assist device patients: clinical relevance of pump speed and power. , 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[6]  D. Burkhoff,et al.  Hemodynamic Ramp Tests in Patients With Left Ventricular Assist Devices. , 2016, JACC. Heart failure.

[7]  Nishant R. Shah,et al.  Echocardiography in the Management of Patients with Left Ventricular Assist Devices: Recommendations from the American Society of Echocardiography. , 2015, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[8]  T. Imamura,et al.  Perioperative Hypoalbuminemia Affects Improvement in Exercise Tolerance After Left Ventricular Assist Device Implantation. , 2015, Circulation journal : official journal of the Japanese Circulation Society.

[9]  F. Gustafsson,et al.  Exercise in heart failure patients supported with a left ventricular assist device. , 2015, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[10]  S. Keteyian,et al.  Cardiac rehabilitation improves functional capacity and patient-reported health status in patients with continuous-flow left ventricular assist devices: the Rehab-VAD randomized controlled trial. , 2014, JACC. Heart failure.

[11]  M. Loebe,et al.  Echocardiographic Evaluation of Hemodynamics in Patients With Systolic Heart Failure Supported by a Continuous-Flow LVAD. , 2014, Journal of the American College of Cardiology.

[12]  H. Ross,et al.  Right ventricular function and prognosis in stable heart failure patients. , 2014, Journal of cardiac failure.

[13]  M. Rutten,et al.  Exercise hemodynamics during extended continuous flow left ventricular assist device support: the response of systemic cardiovascular parameters and pump performance. , 2013, Artificial organs.

[14]  Nir Uriel,et al.  Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: the Columbia ramp study. , 2012, Journal of the American College of Cardiology.

[15]  Christopher Bowles,et al.  Relationship between pump speed and exercise capacity during HeartMate II left ventricular assist device support: influence of residual left ventricular function , 2012, European journal of heart failure.

[16]  B. Whipp,et al.  Ventilatory control of the 'isocapnic buffering' region in rapidly-incremental exercise. , 1989, Respiration physiology.

[17]  B. Whipp,et al.  A new method for detecting anaerobic threshold by gas exchange. , 1986, Journal of applied physiology.

[18]  S. Russell,et al.  Pump speed modulations and sub-maximal exercise tolerance in left ventricular assist device recipients: A double-blind, randomized trial. , 2017, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.