Estimation of single-phase grid voltage fundamental parameters using fixed frequency tuned second-order generalized integrator based technique

This paper proposes a robust technique for accurate estimation of single-phase grid voltage fundamental amplitude and frequency under harmonics. The proposed technique relies on a quadrature signal generator based on a fixed frequency tuned second-order generalized integrator. A differentiation filter is used to estimate the fundamental frequency from the instantaneous phase angle derived from the generated orthogonal voltage systems. The estimated fundamental frequency is then used to obtain the actual fundamental voltage amplitude from the orthogonal voltage systems. The proposed technique does not rely on interdependent loops offering stability and easy tuning process. The technique can reject the negative effects caused by the presence of the harmonics. Experimental results are provided to validate the performance of the proposed technique.

[1]  Giuseppe Fedele,et al.  A recursive scheme for frequency estimation using the modulating functions method , 2010, Appl. Math. Comput..

[2]  Sergio Alejandro Gonzalez,et al.  Harmonic Computation Technique Suitable for Active Power Filters , 2007, IEEE Transactions on Industrial Electronics.

[3]  Vassilios G. Agelidis,et al.  Real-time estimation of single-phase grid voltage frequency using a modulating function based technique , 2013, 2013 IEEE ECCE Asia Downunder.

[4]  M. Karimi-Ghartemani,et al.  Robust and frequency-adaptive measurement of peak value , 2004, IEEE Transactions on Power Delivery.

[5]  Giuseppe Fedele,et al.  Non Adaptive Second-Order Generalized Integrator for Identification of a Biased Sinusoidal Signal , 2012, IEEE Transactions on Automatic Control.

[6]  V. Agelidis,et al.  Tracking of time-varying grid voltage using DFT based second order generalized integrator technique , 2012, 2012 IEEE International Conference on Power System Technology (POWERCON).

[7]  Houshang Karimi,et al.  A magnitude/phase-locked loop system based on estimation of frequency and in-phase/quadrature-phase amplitudes , 2004, IEEE Transactions on Industrial Electronics.

[8]  Giuseppe Fedele,et al.  A Power Electrical Signal Tracking Strategy Based on the Modulating Functions Method , 2009, IEEE Transactions on Industrial Electronics.

[9]  R. Grondin,et al.  Fast adaptive schemes for tracking voltage phasor and local frequency in power transmission and distribution systems , 1991, Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference.

[10]  Heinz A. Preisig,et al.  Theory and application of the modulating function method—I. Review and theory of the method and theory of the spline-type modulating functions , 1993 .

[11]  V.G. Agelidis,et al.  Offset rejection for PLL based synchronization in grid-connected converters , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[12]  M.R. Iravani,et al.  Measurement of harmonics/inter-harmonics of time-varying frequencies , 2005, IEEE Transactions on Power Delivery.

[13]  Md. Shamim Reza,et al.  Grid voltage offset and harmonics rejection using second order generalized integrator and kalman filter technique , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[14]  R. Zivanovic,et al.  An Adaptive Differentiation Filter for Tracking Instantaneous Frequency in Power Systems , 2007, IEEE Transactions on Power Delivery.

[15]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[16]  F. Blaabjerg,et al.  Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.

[17]  F. Blaabjerg,et al.  Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[18]  R. Teodorescu,et al.  A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions , 2012, IEEE Transactions on Power Electronics.

[19]  Frede Blaabjerg,et al.  Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters , 2010, IEEE Transactions on Power Electronics.

[20]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[21]  F. Blaabjerg,et al.  Grid synchronization of power converters using multiple second order generalized integrators , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[22]  Alireza R. Bakhshai,et al.  Derivation and Design of In-Loop Filters in Phase-Locked Loop Systems , 2012, IEEE Transactions on Instrumentation and Measurement.

[23]  B.P. McGrath,et al.  Power converter line synchronization using a discrete Fourier transform (DFT) based on a variable sample rate , 2005, IEEE Transactions on Power Electronics.

[24]  M. Karimi-Ghartemani,et al.  Addressing DC Component in PLL and Notch Filter Algorithms , 2012, IEEE Transactions on Power Electronics.

[25]  M. Akke Frequency Estimation by Demodulation of No Complex Signals , 1997, IEEE Power Engineering Review.

[26]  P. K. Jain,et al.  Problems of Startup and Phase Jumps in PLL Systems , 2012, IEEE Transactions on Power Electronics.

[27]  P.F. Ribeiro,et al.  A PLL-Based Multirate Structure for Time-Varying Power Systems Harmonic/Interharmonic Estimation , 2009, IEEE Transactions on Power Delivery.

[28]  Vassilios G. Agelidis,et al.  Robust estimation of real-time single-phase grid voltage frequency under distorted conditions , 2013, 2013 IEEE ECCE Asia Downunder.

[29]  S.-K. Chung,et al.  Phase-locked loop for grid-connected three-phase power conversion systems , 2000 .