Reduction of false arrhythmia alarms using signal selection and machine learning

In this paper, we propose an algorithm that classifies whether a generated cardiac arrhythmia alarm is true or false. The large number of false alarms in intensive care is a severe issue. The noise peaks caused by alarms can be high and in a noisy environment nurses can experience stress and fatigue. In addition, patient safety is compromised because reaction time of the caregivers to true alarms is reduced. The data for the algorithm development consisted of records of electrocardiogram (ECG), arterial blood pressure, and photoplethysmogram signals in which an alarm for either asystole, extreme bradycardia, extreme tachycardia, ventricular fibrillation or flutter, or ventricular tachycardia occurs. First, heart beats are extracted from every signal. Next, the algorithm selects the most reliable signal pair from the available signals by comparing how well the detected beats match between different signals based on [Formula: see text]-score and selecting the best match. From the selected signal pair, arrhythmia specific features, such as heart rate features and signal purity index are computed for the alarm classification. The classification is performed with five separate Random Forest models. In addition, information on the local noise level of the selected ECG lead is added to the classification. The algorithm was trained and evaluated with the PhysioNet/Computing in Cardiology Challenge 2015 data set. In the test set the overall true positive rates were 93 and 95% and true negative rates 80 and 83%, respectively for events with no information and events with information after the alarm. The overall challenge scores were 77.39 and 81.58.

[1]  Michael Imhoff,et al.  Reducing False Alarms of Intensive Care Online-Monitoring Systems: An Evaluation of Two Signal Extraction Algorithms , 2011, Comput. Math. Methods Medicine.

[2]  C. Tsien,et al.  Poor prognosis for existing monitors in the intensive care unit. , 1997, Critical care medicine.

[3]  U. Gather,et al.  Intensive care unit alarms—How many do we need?* , 2010, Critical care medicine.

[4]  Rui Rodrigues,et al.  Suppression of false arrhythmia alarms using ECG and pulsatile waveforms , 2015, 2015 Computing in Cardiology Conference (CinC).

[5]  A Deshmane,et al.  False arrhythmia alarm suppression using ECG, ABP, and photoplethysmogram , 2009 .

[6]  Qiao Li,et al.  The PhysioNet/Computing in Cardiology Challenge 2015: Reducing false arrhythmia alarms in the ICU , 2015, 2015 Computing in Cardiology Conference (CinC).

[7]  A. Mäkivirta,et al.  The median filter as a preprocessor for a patient monitor limit alarm system in intensive care. , 1991, Computer methods and programs in biomedicine.

[8]  Gari D Clifford,et al.  Heart beat detection in multimodal physiological data using a hidden semi-Markov model and signal quality indices , 2015, Physiological measurement.

[9]  Petr Klimes,et al.  False alarms in intensive care unit monitors: Detection of life-threatening arrhythmias using elementary algebra, descriptive statistics and fuzzy logic , 2015, 2015 Computing in Cardiology Conference (CinC).

[10]  W. Zong,et al.  Using the blood pressure waveform to reduce critical false ECG alarms , 2006, 2006 Computers in Cardiology.

[11]  J. S. Barlow,et al.  Changes in EEG mean frequency and spectral purity during spontaneous alpha blocking. , 1990, Electroencephalography and clinical neurophysiology.

[12]  Neil McIntosh,et al.  Multiple signal integration by decision tree induction to detect artifacts in the neonatal intensive care unit , 2000, Artif. Intell. Medicine.

[13]  Steffen Leonhardt,et al.  Reducing false arrhythmia alarms using robust interval estimation and machine learning , 2015, 2015 Computing in Cardiology Conference (CinC).

[14]  Linda M. Eerikäinen,et al.  Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach , 2015, 2015 Computing in Cardiology Conference (CinC).

[15]  Ying Zhang,et al.  Patient-specific learning in real time for adaptive monitoring in critical care , 2008, J. Biomed. Informatics.

[16]  A. Benzer,et al.  Noise in the ICU , 2005, Intensive Care Medicine.

[17]  Mohammed Saeed,et al.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform , 2008, J. Biomed. Informatics.

[18]  Ursula Gather,et al.  Classifying Alarms in Intensive Care - Analogy to Hypothesis Testing , 2007, AIME.

[19]  Roger G. Mark,et al.  An open-source algorithm to detect onset of arterial blood pressure pulses , 2003, Computers in Cardiology, 2003.

[20]  Leo Breiman,et al.  Random Forests , 2001, Machine Learning.

[21]  Wei Zong,et al.  Reduction of false critical ECG alarms using waveform features of arterial blood pressure and/or photoplethysmogram signals , 2015, 2015 Computing in Cardiology Conference (CinC).

[22]  S. Lawless Crying wolf: False alarms in a pediatric intensive care unit , 1994, Critical care medicine.

[23]  R G Mark,et al.  Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter , 2008, Physiological measurement.

[24]  Massimo Mischi,et al.  Low-complexity R-peak detection for ambulatory fetal monitoring , 2012, Physiological measurement.

[25]  Qiao Li,et al.  ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction , 2013, IEEE Transactions on Biomedical Engineering.

[26]  José Vicente,et al.  Heartbeat fusion algorithm to reduce false alarms for arrhythmias , 2015, 2015 Computing in Cardiology Conference (CinC).

[27]  Mohammad Bagher Shamsollahi,et al.  Life-Threatening Arrhythmia Verification in ICU Patients Using the Joint Cardiovascular Dynamical Model and a Bayesian Filter , 2011, IEEE Transactions on Biomedical Engineering.

[28]  Jean-Marc Vesin,et al.  A multimodal approach to reduce false arrhythmia alarms in the intensive care unit , 2015, 2015 Computing in Cardiology Conference (CinC).

[29]  K. Graham,et al.  Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. , 2010, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[30]  Barbara Oakley,et al.  Noise in hospital intensive care units--a critical review of a critical topic. , 2012, Journal of critical care.