Quantifying cortical bone free water using short echo time (STE-MRI) at 1.5 T.

PURPOSE The purpose of our study was to use Dual-TR STE-MR protocol as a clinical tool for cortical bone free water quantification at 1.5 T and validate it by comparing the obtained results (MR-derived results) with dehydration results. METHODS Human studies were compliant with HIPPA and were approved by the institutional review board. Short Echo Time (STE) MR imaging with different Repetition Times (TRs) was used for quantification of cortical bone free water T1 (T1free) and concentration (ρfree). The proposed strategy was compared with the dehydration technique in seven bovine cortical bone samples. The agreement between the two methods was quantified by using Bland and Altman analysis. Then we applied the technique on a cross-sectional population of thirty healthy volunteers (18F/12M) and examined the association of the biomarkers with age. RESULTS The mean values of ρfree for bovine cortical bone specimens were quantified as 4.37% and 5.34% by using STE-MR and dehydration techniques, respectively. The Bland and Altman analysis showed good agreement between the two methods along with the suggestion of 0.99% bias between them. Strong correlations were also reported between ρfree (r2 = 0.62) and T1free and age (r2 = 0.8). The reproducibility of the method, evaluated in eight subjects, yielded an intra-class correlation of 0.95. CONCLUSION STE-MR imaging with dual-TR strategy is a clinical solution for quantifying cortical bone ρfree and T1free.

[1]  J A McGeough,et al.  Age-related changes in the tensile properties of cortical bone. The relative importance of changes in porosity, mineralization, and microstructure. , 1993, The Journal of bone and joint surgery. American volume.

[2]  Matthew D Robson,et al.  Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences. , 2005, Magnetic resonance imaging.

[3]  O. Johnell,et al.  Ten Year Probabilities of Osteoporotic Fractures According to BMD and Diagnostic Thresholds , 2001, Osteoporosis International.

[4]  H. Saligheh Rad,et al.  Quantification of Human Cortical Bone Bound and Free Water in Vivo with Ultrashort Echo Time MR Imaging: A Model-based Approach. , 2017, Radiology.

[5]  Adam C. Searleman,et al.  Fast quantitative 3D ultrashort echo time MRI of cortical bone using extended cones sampling , 2019, Magnetic resonance in medicine.

[6]  H. Saligheh Rad,et al.  Liquid Calibration Phantoms in Ultra-Low-Dose QCT for the Assessment of Bone Mineral Density. , 2019, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[7]  P. Delmas,et al.  Bone quality--the material and structural basis of bone strength and fragility. , 2006, The New England journal of medicine.

[8]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[9]  E. Chang,et al.  The effect of excitation and preparation pulses on nonslice selective 2D UTE bicomponent analysis of bound and free water in cortical bone at 3T. , 2014, Medical physics.

[10]  J. Burnham,et al.  Divergent Effects of Glucocorticoids on Cortical and Trabecular Compartment BMD in Childhood Nephrotic Syndrome , 2009, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[11]  T1 Quantification of the Cortical Bone Employing Short-TE MRI at 1.5 and 3 Tesla , 2014 .

[12]  J. Love,et al.  Quantifying cortical bone water in vivo by three‐dimensional ultra‐short echo‐time MRI , 2011, NMR in biomedicine.

[13]  Mary Kate Manhard,et al.  30‐Second bound and pore water concentration mapping of cortical bone using 2D UTE with optimized half‐pulses , 2017, Magnetic resonance in medicine.

[14]  E. Chang,et al.  Ultrashort echo time bi‐component analysis of cortical bone—a field dependence study , 2014, Magnetic resonance in medicine.

[15]  Jeffry S Nyman,et al.  Clinically compatible MRI strategies for discriminating bound and pore water in cortical bone , 2012, Magnetic resonance in medicine.

[16]  J. Nyman,et al.  Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of bone. , 2008, Bone.

[17]  A. Wright,et al.  Quantitative MRI for the assessment of bone structure and function , 2006, NMR in biomedicine.

[18]  Koichi Masuda,et al.  Ultrashort echo time (UTE) imaging with bi-component analysis: bound and free water evaluation of bovine cortical bone subject to sequential drying. , 2012, Bone.

[19]  Mary B Leonard,et al.  Cortical bone water: in vivo quantification with ultrashort echo-time MR imaging. , 2008, Radiology.

[20]  Volumetric Cortical Bone Porosity Assessment with MR Imaging: Validation and Clinical Feasibility. , 2015, Radiology.

[21]  W. Bradley,et al.  MRI: The Basics , 1997 .

[22]  G. Saggese,et al.  Bone Quality Assessment by Quantitative Ultrasound of Proximal Phalanxes of the Hand in Healthy Subjects Aged 3–21 Years , 2001, Pediatric Research.

[23]  J. Nyman,et al.  Assessment of water distribution changes in human cortical bone by nuclear magnetic resonance , 2007 .

[24]  L. Dorr,et al.  Structural and cellular assessment of bone quality of proximal femur. , 1993, Bone.

[25]  Reinhilde Jacobs,et al.  Bone quality assessment based on cone beam computed tomography imaging. , 2009, Clinical oral implants research.

[26]  D. D’Lima,et al.  Evaluation of bound and pore water in cortical bone using ultrashort‐TE MRI , 2015, NMR in biomedicine.

[27]  Mary Kate Manhard,et al.  Validation of quantitative bound‐ and pore‐water imaging in cortical bone , 2014, Magnetic resonance in medicine.

[28]  Mary Kate Manhard,et al.  In Vivo Quantitative MR Imaging of Bound and Pore Water in Cortical Bone. , 2015, Radiology.

[29]  F. Wehrli Image-based Assessment of Cortical Bone , 2012 .

[30]  Yajun Ma,et al.  Three‐dimensional ultrashort echo time imaging with tricomponent analysis for human cortical bone , 2019, Magnetic resonance in medicine.

[31]  J. Nyman,et al.  The influence of water removal on the strength and toughness of cortical bone. , 2006, Journal of biomechanics.

[32]  T1 correlates age: A short-TE MR relaxometry study in vivo on human cortical bone free water at 1.5T. , 2016, Bone.

[33]  Mary Kate Manhard,et al.  MRI-derived bound and pore water concentrations as predictors of fracture resistance. , 2016, Bone.

[34]  Felix W Wehrli,et al.  Bi‐component T2* analysis of bound and pore bone water fractions fails at high field strengths , 2015, NMR in biomedicine.

[35]  Felix W Wehrli,et al.  In vivo MRI of submillisecond T2 species with two‐dimensional and three‐dimensional radial sequences and applications to the measurement of cortical bone water , 2008, NMR in biomedicine.

[36]  Adam C. Searleman,et al.  Volumetric mapping of bound and pore water as well as collagen protons in cortical bone using 3D ultrashort echo time cones MR imaging techniques. , 2019, Bone.

[37]  Jeffry S Nyman,et al.  Characterization of 1H NMR signal in human cortical bone for magnetic resonance imaging , 2010, Magnetic resonance in medicine.

[38]  Jiang Du,et al.  Ultrashort echo time imaging with bicomponent analysis , 2012, Magnetic resonance in medicine.

[39]  F. Wehrli,et al.  Cortical bone water concentration: dependence of MR imaging measures on age and pore volume fraction. , 2014, Radiology.

[40]  Graham Wright,et al.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. , 2004, AJR. American journal of roentgenology.

[41]  D. Gochberg,et al.  Non-invasive Predictors of Human Cortical Bone Mechanical Properties: T2-Discriminated 1H NMR Compared with High Resolution X-ray , 2011, PloS one.