Real time digital signal processing implementation for an APD-based PET scanner with phoswich detectors

Recent progress in advanced digital signal processing provides an opportunity to expand the computation power required for real time extraction of event characteristics in APD-based positron emission tomography (PET) scanners. These developments are made possible by a highly parallel data acquisition (DAQ) system based on an integrated analog front-end and a high-speed fully digital signal processing section that directly samples the output of each preamplifier with a free-running, off-the-shelf, 45-MHz MAX1193 analog-to-digital converter that feeds the sampled data into a field programmable gate array VirtexII PRO from Xilinx. This FPGA features ~31,000 logic cells and 2 PowerPC processors, which allows up to 64 channels to be processed simultaneously. Each channel has its own digital signal processing chain including a trigger, a baseline restorer and a timestamp algorithm. Various timestamp algorithms have been tested so far, achieving a coincidence timing resolution of 3.2 ns FWHM for APD-LSO and 11.4 ns FWHM for APD-BGO detectors, respectively. Channels are then multiplexed into a TMS320C6414 DSP processor from Texas Instruments for crystal identification by an ARMAX recursive algorithm borrowed from identification and vector quantization theory. The system can sustain an event rate of 10 000 events/s/channel without electronic dead time

[1]  S R Cherry,et al.  Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out , 2004, Physics in medicine and biology.

[2]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[3]  H. Murayama,et al.  Design of a depth of interaction detector with a PS-PMT for PET , 1999 .

[4]  R. Fontaine,et al.  Design and performance of 0.18-/spl mu/m CMOS charge preamplifiers for APD-based PET scanners , 2004, IEEE Transactions on Nuclear Science.

[5]  W. Moses,et al.  Monte Carlo optimization of depth-of-interaction resolution in PET crystals , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[6]  H Ostertag,et al.  A Preliminary Evaluation of a Dual Crystal Positron Camera , 1987, Journal of computer assisted tomography.

[7]  R. Fontaine,et al.  Experimental results of identification and vector quantization algorithms for DOI measurement in digital PET scanners with phoswich detectors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[8]  R. Lecomte,et al.  A novel APD-based detector module for multi-modality PET/SPECT/CT scanners , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[9]  Magnus Dahlbom,et al.  Depth of interaction for PET using segmented crystals , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[10]  W. Moses,et al.  A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction , 1995 .

[11]  R. Nutt,et al.  Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes , 1998 .

[12]  G. Brandenburg,et al.  The data acquisition system of ClearPET neuro - a small animal PET scanner , 2006, IEEE Transactions on Nuclear Science.

[13]  Horst Halling,et al.  Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET , 2002 .

[14]  Roger Lecomte,et al.  Initial results from the Sherbrooke avalanche photodiode positron tomograph , 1996 .

[15]  Anne Bol,et al.  Response Function for the Ecat3 Positron Camera - Monte-carlo Simulation and Experiment , 1986 .

[16]  Michael V. Green,et al.  Depth identification accuracy of a three layer phoswich PET detector module , 1999 .

[17]  Hideo Murayama,et al.  A depth of interaction detector for PET with GSO crystals doped with different amounts of Ce , 2001 .

[18]  R. Lecomte,et al.  An APD-based quad scintillator detector module with pulse shape discrimination coding for PET , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[19]  R. Fontaine,et al.  Real time coincidence detection system for digital high resolution APD-based animal PET scanner , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[20]  Magnus Dahlbom,et al.  Depth of interaction for PET using segmented crystals , 1997 .

[21]  Piotr Szupryczynski,et al.  Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes , 2003 .