A novel methodology for on-site validation of RV measurement data

Large number of power transformers that are operating today have already outlived their designed life. Such equipments, which are now prone to failures, are still in operation in order to maximize asset utilization. Extending the life of such equipments by policies based on proper condition assessment can mean substantial saving for the utilities. Modern techniques based on dielectric response measurement and analysis provides valuable information regarding the condition of the HV insulation. However, commercial equipments available for recording dielectric response are extremely costly. The paper reports the design of a low-cost instrument developed at High Tension Laboratory of Jadavpur University for measurement of return voltage of high voltage oil-paper insulation. In addition a method is also discussed that facilitate user to carry out on-site validation of RV measurements recorded using the above instrument.

[1]  G. Csepes,et al.  Practical foundations of the RVM (recovery voltage method for oil/paper insulation diagnosis) , 1998, 1998 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.98CH36257).

[2]  B. Chatterjee,et al.  A Hybrid Filtering Scheme for Proper Denoising of Real-time Data in Dielectric Spectroscopy , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Alexander Mamishev,et al.  Moisture equilibrium in transformer paper-oil systems , 1999 .

[4]  P. Purkait,et al.  Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements , 2004, IEEE Transactions on Power Delivery.

[5]  P. Purkait,et al.  Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  L. Adeen,et al.  Dielectric spectroscopy in time and frequency domain applied to diagnostics of power transformers , 2000, Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials (Cat. No.00CH36347).

[7]  T. Oommen,et al.  Moisture Equilibrium Charts for Transformer Insulation Drying Practice , 1984, IEEE Transactions on Power Apparatus and Systems.

[8]  P. Purkait,et al.  Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements , 2005, IEEE Transactions on Power Delivery.

[9]  J. Rozenkrons,et al.  Temperature dependence of return voltage characteristics , 1998, Proceedings of 1998 International Symposium on Electrical Insulating Materials. 1998 Asian International Conference on Dielectrics and Electrical Insulation. 30th Symposium on Electrical Insulating Ma.