Use of bedside activated partial thromboplastin time monitor to adjust heparin dosing after thrombolysis for acute myocardial infarction: results of GUSTO-I. Global Utilization of Streptokinase and TPA for Occluded Coronary Arteries.
暂无分享,去创建一个
R. Califf | E. Topol | C. Granger | J. Hirsh | R. Becker | P. Aylward | P. Aylward | E. Bovill | K. M. Zabel | K. Zabel | Richard C. Becker | C. Granger | Jack Hirsh
[1] E. Braunwald,et al. Relation between systemic anticoagulation as determined by activated partial thromboplastin time and heparin measurements and in-hospital clinical events in unstable angina and non-Q wave myocardiaL infarction. Thrombolysis in Myocardial Ischemia III B Investigators. , 1996, American heart journal.
[2] K. Lee,et al. Activated partial thromboplastin time and outcome after thrombolytic therapy for acute myocardial infarction: results from the GUSTO-I trial. , 1996, Circulation.
[3] J Col,et al. Predictors of 30-day mortality in the era of reperfusion for acute myocardial infarction. Results from an international trial of 41,021 patients. GUSTO-I Investigators. , 1995, Circulation.
[4] R. Becker,et al. Bedside coagulation monitoring in heparin-treated patients with active thromboembolic disease: a coronary care unit experience. , 1994, American heart journal.
[5] D. Reich,et al. Comparison of bedside coagulation monitoring tests with standard laboratory tests in patients after cardiac surgery. , 1993, Anesthesia and analgesia.
[6] Frans Van de Werf,et al. An international randomized trial comparing four thrombolytic strategies for acute myocardial infarction. , 1993, The New England journal of medicine.
[7] M. Simoons,et al. Correlation between level of heparinization and patency of the infarct-related coronary artery after treatment of acute myocardial infarction with alteplase (rt-PA). , 1992, Journal of the American College of Cardiology.
[8] J. Hsia,et al. Heparin-induced prolongation of partial thromboplastin time after thrombolysis: relation to coronary artery patency. HART Investigators. , 1992, Journal of the American College of Cardiology.
[9] D. Sane,et al. Exploration of rapid bedside monitoring of coagulation and fibrinolysis parameters during thrombolytic therapy. , 1992 .
[10] C. Corke,et al. A Comparison of Five Devices for the Bedside Monitoring of Heparin Therapy , 1991, Anaesthesia and intensive care.
[11] K. Mann,et al. Hemorrhagic events during therapy with recombinant tissue-type plasminogen activator, heparin, and aspirin for acute myocardial infarction. Results of the Thrombolysis in Myocardial Infarction (TIMI), Phase II Trial. , 1991, Annals of internal medicine.
[12] E. Topol,et al. Adjuncts to thrombolysis for myocardial reperfusion. , 1991, Annals of internal medicine.
[13] D. Adler,et al. Measurement of the activated partial thromboplastin time from a capillary (fingerstick) sample of whole blood. A new method for monitoring heparin therapy. , 1991, American journal of clinical pathology.
[14] P N Valenstein,et al. Sensitivity, specificity, and reproducibility of four measures of laboratory turnaround time. , 1989, American journal of clinical pathology.
[15] D. Doyle,et al. Comparison of high-dose with low-dose subcutaneous heparin to prevent left ventricular mural thrombosis in patients with acute transmural anterior myocardial infarction. , 1989, The New England journal of medicine.
[16] A. Shojania,et al. The variations between heparin sensitivity of different lots of activated partial thromboplastin time reagent produced by the same manufacturer. , 1988, American journal of clinical pathology.
[17] D. Mungall,et al. A novel whole blood capillary technic for measuring the prothrombin time. , 1987, American journal of clinical pathology.
[18] M. Parker,et al. Role of heparin after intravenous thrombolytic therapy for acute myocardial infarction. , 1987, The American journal of cardiology.
[19] T. Bjornsson,et al. Variability in heparin sensitivity of APTT reagents. , 1986, American journal of clinical pathology.
[20] E. Gottfried,et al. The Effects of Inaccurate Blood Sample Volume on Prothrombin Time (PT) and Activated Partial Thromboplastin Time (aPTT) , 1982, Thrombosis and Haemostasis.
[21] J. Brandt,et al. Laboratory monitoring of heparin. Effect of reagents and instruments on the activated partial thromboplastin time. , 1981, American journal of clinical pathology.
[22] M. Corn,et al. Control of Heparin Therapy With Activated Partial Thromboplastin Times , 1967 .