An experimental clinical evaluation of EIT imaging with ℓ1 data and image norms

Electrical impedance tomography (EIT) produces an image of internal conductivity distributions in a body from current injection and electrical measurements at surface electrodes. Typically, image reconstruction is formulated using regularized schemes in which ℓ2-norms are used for both data misfit and image prior terms. Such a formulation is computationally convenient, but favours smooth conductivity solutions and is sensitive to outliers. Recent studies highlighted the potential of ℓ1-norm and provided the mathematical basis to improve image quality and robustness of the images to data outliers. In this paper, we (i) extended a primal-dual interior point method (PDIPM) algorithm to 2.5D EIT image reconstruction to solve ℓ1 and mixed ℓ1/ℓ2 formulations efficiently, (ii) evaluated the formulation on clinical and experimental data, and (iii) developed a practical strategy to select hyperparameters using the L-curve which requires minimum user-dependence. The PDIPM algorithm was evaluated using clinical and experimental scenarios on human lung and dog breathing with known electrode errors, which requires a rigorous regularization and causes the failure of reconstruction with an ℓ2-norm solution. The results showed that an ℓ1 solution is not only more robust to unavoidable measurement errors in a clinical setting, but it also provides high contrast resolution on organ boundaries.

[1]  David L Donoho,et al.  Compressed sensing , 2006, IEEE Transactions on Information Theory.

[2]  Tony F. Chan,et al.  Aspects of Total Variation Regularized L[sup 1] Function Approximation , 2005, SIAM J. Appl. Math..

[3]  Albert Tarantola,et al.  Inverse problem theory - and methods for model parameter estimation , 2004 .

[4]  Andy Adler,et al.  In Vivo Impedance Imaging With Total Variation Regularization , 2010, IEEE Transactions on Medical Imaging.

[5]  Manuchehr Soleimani,et al.  Level set based reconstruction algorithm for EIT lung images , 2011 .

[6]  G Hahn,et al.  Systematic errors of EIT systems determined by easily-scalable resistive phantoms , 2008, Physiological measurement.

[7]  R. van Mastrigt,et al.  Development of a CFD urethral model to study flow-generated vortices under different conditions of prostatic obstruction , 2007, Physiological measurement.

[8]  Jari P. Kaipio,et al.  A Bayesian approach and total variation priors in 3D electrical impedance tomography , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[9]  Lawrence Weiskrantz,et al.  Discussions and conclusions , 1998 .

[10]  A. V. Schaik,et al.  L1 regularization method in electrical impedance tomography by using the L1-curve (Pareto frontier curve) , 2012 .

[11]  Andy Adler,et al.  Electrical Impedance Tomography reconstruction using ℓ1 norms for data and image terms , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  M. Soleimani,et al.  Level set reconstruction of conductivity and permittivity from boundary electrical measurements using experimental data , 2006 .

[13]  Andy Adler,et al.  A primal–dual interior-point framework for using the L1 or L2 norm on the data and regularization terms of inverse problems , 2012 .

[14]  Raymond H. Chan,et al.  An Efficient Two-Phase ${\rm L}^{1}$-TV Method for Restoring Blurred Images with Impulse Noise , 2010, IEEE Transactions on Image Processing.

[15]  Yue Xiu-li,et al.  Multifunctional magnetic nanoparticles for magnetic resonance image-guided photothermal therapy for cancer , 2014 .

[16]  Andy Adler,et al.  Whither lung EIT: Where are we, where do we want to go and what do we need to get there? , 2012, Physiological measurement.

[17]  Andy Adler,et al.  Automatic detection of detached and erroneous electrodes in electrical impedance tomography , 2005, Physiological measurement.

[18]  A Adler,et al.  Monitoring changes in lung air and liquid volumes with electrical impedance tomography. , 1997, Journal of applied physiology.

[19]  Hervé Gagnon,et al.  Accounting for hardware imperfections in EIT image reconstruction algorithms , 2007, Physiological measurement.

[20]  Michael L. Overton,et al.  An Efficient Primal-Dual Interior-Point Method for Minimizing a Sum of Euclidean Norms , 2000, SIAM J. Sci. Comput..

[21]  L. Rudin,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[22]  William R B Lionheart,et al.  A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software project , 2002 .

[23]  Camille Gomez-Laberge,et al.  A Unified Approach for EIT Imaging of Regional Overdistension and Atelectasis in Acute Lung Injury , 2012, IEEE Transactions on Medical Imaging.

[24]  Bangti Jin,et al.  A duality-based splitting method for ` 1-TV image restoration with automatic regularization parameter choice ∗ , 2009 .

[25]  P. Hansen Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion , 1987 .

[26]  William R B Lionheart,et al.  Uses and abuses of EIDORS: an extensible software base for EIT , 2006, Physiological measurement.