Volumetric capillary cytometry: a new method for absolute cell enumeration.

This article describes a novel cytometry system that is capable of imaging, identifying, and counting populations of fluorescently labeled cells within a precisely known volume of unlysed whole blood contained in a precision capillary. The whole blood is reacted with dye-labeled antibodies directed at cell surface antigens. A red excitation source (helium-neon laser) is used to minimize auto-fluorescence and interference by blood components. A two-color fluorescence detection system is described, using the dyes Cy5 and Cy5.5, allowing the simultaneous detection and quantitation of two different types of surface antigens. Image processing techniques are used to identify cellular events in the image and to quantitate the fluorescent intensities in both color planes. The utility of this technique is demonstrated by performing absolute CD3+/CD4+ lymphocyte counts in whole blood, with minimal sample preparation, and with the blood sample completely contained in a disposable cartridge. A correlation study comparing this technique to flow cytometry gives a correlation coefficient of 0.98. In addition, the ability of this system to monitor reaction kinetics is demonstrated with a measurement of the rate of association of the anti-CD4 antibody onto the surface of CD4+ lymphocytes.

[1]  L. Kamentsky,et al.  Microscope-based multiparameter laser scanning cytometer yielding data comparable to flow cytometry data. , 1991, Cytometry.

[2]  R. Detels,et al.  T-cell subset alterations in HIV-infected homosexual men: NIAID Multicenter AIDS cohort study. , 1989, Clinical immunology and immunopathology.

[3]  R. Gelman,et al.  Guideline for flow cytometric immunophenotyping: a report from the National Institute of Allergy and Infectious Diseases, Division of AIDS. , 1993, Cytometry.

[4]  D Burger,et al.  Acousto-optic laser-scanning cytometer. , 1988, Cytometry.

[5]  Howard M. Shapiro,et al.  Practical Flow Cytometry , 1985 .

[6]  D. Hirschkorn,et al.  Evaluation of four alternative methodologies for determination of absolute CD4+ lymphocyte counts. The National Heart, Lung, and Blood Institute Retrovirus Epidemiology Donor Study. , 1995, Journal of acquired immune deficiency syndromes and human retrovirology : official publication of the International Retrovirology Association.

[7]  D S Stein,et al.  CD4+ lymphocyte cell enumeration for prediction of clinical course of human immunodeficiency virus disease: a review. , 1992, The Journal of infectious diseases.

[8]  A. Landay,et al.  Assessment of Interlaboratory Variability of Immunophenotyping , 1993, Annals of the New York Academy of Sciences.

[9]  A. Landay,et al.  Precision and accuracy of absolute lymphocyte counts. , 1989, Clinical immunology and immunopathology.

[10]  Robert J. Obremski,et al.  Near IR: new sources, new detectors, and new solutions to old problems , 1993, Photonics West - Lasers and Applications in Science and Engineering.

[11]  J V Giorgi,et al.  Application of flow cytometry to the study of HIV infection. , 1990, AIDS.

[12]  F. Chiarotti,et al.  CD4 Lymphocyte enumeration: comparison between flow cytometry and enzyme immunoassay. , 1995, Cytometry.

[13]  J. Margolick,et al.  Quality control in the flow cytometric measurement of T-lymphocyte subsets: the multicenter AIDS cohort study experience. The Multicenter AIDS Cohort Study Group. , 1990, Clinical immunology and immunopathology.

[14]  A. Landay,et al.  Prediction of CD4 count from CD4 percentage: experience from three laboratories. , 1993, AIDS.

[15]  R. D. Evans,et al.  Atomic Nucleus , 2020, Definitions.

[16]  W. Groner,et al.  Variability in absolute lymphocyte counts obtained by automated cell counters. , 1995, Cytometry.