A discriminative approach to harmonic emission assessment

With the onset of renewable power sources onto the network, such as Photovoltaic power plants contributing to Total Harmonic Distortion (THD) in voltage, a methodology to quantify their contribution to the THD in voltage at the point of common coupling is needed. This paper give an overview of existing theory on the quantification of harmonic emission and in particular the method proposed by the CIGRE/CIREDC4.109 working group. It is concluded that the application of this method by single-point measurements can be improved upon by using synchronized multiple-point measurements. Discrimination to identity the harmonic currents regarded as emission is attempted in the assessment of harmonic emission at a PV plant feeding into a 22 kV distribution network.

[1]  Yao Xiao,et al.  Harmonic summation and assessment based on probability distribution of phase angle , 2012, 2012 IEEE 15th International Conference on Harmonics and Quality of Power.

[2]  Lorenzo Peretto,et al.  Investigation on Multipoint Measurement Techniques for PQ Monitoring , 2006, IEEE Transactions on Instrumentation and Measurement.

[3]  Ozgul Salor,et al.  Identification of Harmonic Current Contributions of Iron and Steel Plants Based on Time-Synchronized Field Measurements—Part I: At PCC , 2014 .

[4]  Pedro M. de Almeida,et al.  Considerations on hosting capacity for harmonic distortions on transmission and distribution systems , 2015 .

[5]  Emmanuel De Jaeger Disturbance emission level assessment techniques (CIGRE-CIRED joint working group C4.109) , 2009 .

[6]  Duan Serfontein The assessment of waveform distortion in power systems : validation of methods based on single–point measurements , 2011 .

[7]  Francis M. Fernandez,et al.  Estimation of supply side harmonics by using network impedance data , 2010, 2010 Joint International Conference on Power Electronics, Drives and Energy Systems & 2010 Power India.

[8]  A. P. J. Rens,et al.  On techniques for the localisation of multiple distortion sources in three‐phase networks: Time domain verification , 2001 .

[9]  Hualin Gong,et al.  A New Assessment Method of Customer Harmonic Emission Level , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[10]  B. Blazic,et al.  Methods for estimating customer voltage harmonic emission levels , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[11]  W. G. Sherman Summation of harmonics with random phase angles , 1972 .

[12]  Wilsun Xu,et al.  An Investigation on the Validity of Power-Direction Method for Harmonic Source Determination , 2001 .

[13]  Johan Rens,et al.  Where is the power of the IEEE 1459-2010? , 2014, 2014 IEEE International Workshop on Applied Measurements for Power Systems Proceedings (AMPS).

[14]  I. N. Santos,et al.  A case study of sharing the harmonic voltage distortion responsibility between the utility and the consumer , 2009 .

[15]  G. Chicco,et al.  Characterisation and assessment of the harmonic emission of grid-connected photovoltaic systems , 2005, 2005 IEEE Russia Power Tech.

[16]  Mario Bazina,et al.  Comparison of various methods for determining direction of harmonic distortion by measuring in point of common coupling , 2014, 2014 IEEE International Energy Conference (ENERGYCON).

[17]  Alessandro Ferrero,et al.  Fuzzy Metrology-Sound Approach to the Identification of Sources Injecting Periodic Disturbances in Electric Networks , 2011, IEEE Transactions on Instrumentation and Measurement.