Effect of cross section on critical velocity in longitudinally ventilated tunnel fires

Numerical and theoretical work was conducted to investigate the effect of tunnel cross section on critical velocity for smoke control in longitudinally ventilated tunnel fires. The results show that for small fires, the critical velocity decreases with both the increasing tunnel height and tunnel width. For large fires, the critical velocity significantly increases with the increasing tunnel height but is independent of tunnel width. Different calculation models are compared with a focus on effect of tunnel cross section. A new correlation is proposed to account for the effect of tunnel width based on the previous model.

[1]  J. P. Kunsch,et al.  Simple model for control of fire gases in a ventilated tunnel , 2002 .

[2]  Shuai Liu,et al.  Flame length elongation behavior of medium hydrocarbon pool fires in cross air flow , 2013 .

[3]  Olivier Vauquelin,et al.  Parametrical study of the back flow occurrence in case of a buoyant release into a rectangular channel , 2005 .

[4]  Haukur Ingason,et al.  The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires , 2011 .

[5]  Haukur Ingason,et al.  Runehamar tunnel fire tests , 2015 .

[6]  Yasushi Oka,et al.  Control of smoke flow in tunnel fires , 1995 .

[7]  Bart Merci,et al.  Relation Between Horizontal Ventilation Velocity and Backlayering Distance in Large Closed Car Parks , 2008 .

[8]  Hong Sun Ryou,et al.  An Experimental Study of the Effect of the Aspect Ratio on the Critical Velocity in Longitudinal Ventilation Tunnel Fires , 2005 .

[9]  Haukur Ingason,et al.  Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires , 2010 .

[10]  Olivier Vauquelin,et al.  Influence of tunnel width on longitudinal smoke control , 2006 .

[11]  Kuang-Chung Tsai,et al.  Effect of vehicular blockage on critical ventilation velocity and tunnel fire behavior in longitudinally ventilated tunnels , 2012 .

[12]  L H Hu,et al.  Critical wind velocity for arresting upwind gas and smoke dispersion induced by near-wall fire in a road tunnel. , 2008, Journal of hazardous materials.

[13]  Haukur Ingason,et al.  Effect of cross section and ventilation on heat release rates in tunnel fires , 2016 .

[14]  Wan Ki Chow,et al.  Studies on buoyancy-driven back-layering flow in tunnel fires , 2008 .

[15]  Haukur Ingason,et al.  Model scale tunnel fire tests with water-based fire suppression systems , 2014 .

[16]  R. L. Alpert Turbulent Ceiling-Jet Induced by Large-Scale Fires , 1975 .

[17]  P. H. Thomas,et al.  THE SIZE OF FLAMES FROM NATURAL FIRES , 1962 .

[18]  Robert F. Chaiken,et al.  Interaction Between Duct Fires and Ventilation Flow: An Experimental Study , 1979 .

[19]  Haukur Ingason,et al.  Scale modeling and numerical simulation of smoke control for rescue stations in long railway tunnels , 2012 .

[20]  P. H. Thomas,et al.  THE MOVEMENT OF BUOYANT FLUID AGAINST A STREAM AND THE VENTING OF UNDERGROUND FIRES , 1958 .

[21]  Haukur Ingason,et al.  Tunnel Fire Dynamics , 2015 .

[22]  P. H. Thomas,et al.  THE MOVEMENT OF SMOKE IN HORIZONTAL PASSAGES AGAINST AN AIR FLOW , 1968 .

[23]  Kai Zhu,et al.  Prediction of smoke back-layering length under different longitudinal ventilations in the subway tunnel with metro train , 2016 .

[24]  Y. Wu,et al.  Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity , 2000 .

[25]  Haukur Ingason,et al.  The maximum ceiling gas temperature in a large tunnel fire , 2012 .