Techniques for the Improvement of the Lightning Back-Flashover Performance of Double Circuit HVDC Lines

Abstract This paper addresses different issues regarding the lightning back-flashover performance of HVDC lines, especially regarding double-circuit configurations. In such configurations, two poles may present very similar flashover risks due to a lightning strike, leading to a double flashover. Therefore, it is of particular interest to investigate solutions to protect at least one circuit from flashovers and avoid the temporary loss of the transmitted power and the associated consequences to the system. In this work, electromagnetic transient models are implemented to investigate two solutions for the improvement of the lightning performance: the installation of surge arresters and the use of unbalanced insulation. The results are analysed thoroughly and the mechanisms and theoretical bases behind them are explained. In addition to the grounding resistance of the tower, the coupling between the conductors and the DC pole configuration within the tower also play a major role in determining the lightning back-flashover performance of a double circuit HVDC line. The installation of a single arrester can achieve a very significant improvement of the overall lightning performance of a tower. A proper implementation of an unbalanced insulation solution is very effective in limiting the incidence of double flashovers while maintaining an optimal overall performance.

[1]  Qi Yang,et al.  Research on Lightning Performance of Back-flashover of UHV Direct Current Double-circuit Mixed-voltage Transmission Lines on the Same Tower , 2018, 2018 10th International Conference on Communications, Circuits and Systems (ICCCAS).

[2]  Silverio Visacro,et al.  Lightning Performance of Transmission Lines: Requirements of Tower-Footing Electrodes Consisting of Long Counterpoise Wires , 2016, IEEE Transactions on Power Delivery.

[3]  M. Kawai,et al.  Design and Performance of Unbalanced Insulation in Double-Circuit Transmission Lines , 1965 .

[4]  S. Visacro,et al.  The Use of Underbuilt Wires to Improve the Lightning Performance of Transmission Lines , 2012, IEEE Transactions on Power Delivery.

[5]  L. Grcev,et al.  Modeling of Grounding Electrodes Under Lightning Currents , 2009, IEEE Transactions on Electromagnetic Compatibility.

[6]  Jinliang He,et al.  Comparison and Analysis on Key Performance of EHV/UHV DC Transmission Line Surge Arresters , 2018, 2018 34th International Conference on Lightning Protection (ICLP).

[7]  Mat Darveniza,et al.  Lightning Performance of Double-Circuit Transmission Lines , 1970 .

[8]  Heng-Ming Tai,et al.  Reliability Evaluation and Weak Component Identification of ±500-kV HVDC Transmission Systems With Double-Circuit Lines on the Same Tower , 2018, IEEE Transactions on Power Delivery.

[9]  Jinliang He,et al.  A design of unbalanced insulation to improve the lightning performance of multi-circuit transmission lines , 2012, 2012 International Conference on Lightning Protection (ICLP).

[10]  M. Popov,et al.  On high-frequency circuit equivalents of a vertical ground rod , 2005, IEEE Transactions on Power Delivery.

[11]  Feng Zhenghua,et al.  Research on reducing grounding resistance of transmission line tower grounding grid , 2011, 2011 International Conference on Electrical and Control Engineering.

[12]  Hailiang Lu,et al.  Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[13]  P. Pinceti,et al.  A simplified model for zinc oxide surge arresters , 1999 .

[14]  Gang Wang,et al.  Fault Analysis and Traveling-Wave-Based Protection Scheme for Double-Circuit LCC-HVDC Transmission Lines With Shared Towers , 2018, IEEE Transactions on Power Delivery.

[15]  Silverio Visacro,et al.  The Use of the Impulse Impedance as a Concise Representation of Grounding Electrodes in Lightning Protection Applications , 2018, IEEE Transactions on Electromagnetic Compatibility.

[16]  Jiansheng Yuan,et al.  Analysis of Electric Field, Ion Flow Density, and Corona Loss of Same-Tower Double-Circuit HVDC Lines Using Improved FEM , 2009, IEEE Transactions on Power Delivery.

[17]  Jiayu Lu,et al.  A Calculation Method for the Electric Field Under Double-Circuit HVDC Transmission Lines , 2008, IEEE Transactions on Power Delivery.

[18]  Takatoshi Shindo,et al.  A New Calculation Method of Breakdown Voltage-Time Characteristics of Long Air Gaps , 1985, IEEE Transactions on Power Apparatus and Systems.

[19]  Rafael M. Gomes,et al.  Concerns on surge-arrester application for improving the backflashover rate of transmission lines , 2018, 2018 34th International Conference on Lightning Protection (ICLP).