Predicting Subcutaneous Glucose Concentration in Humans: Data-Driven Glucose Modeling

The combination of predictive data-driven models with frequent glucose measurements may provide for an early warning of impending glucose excursions and proactive regulatory interventions for diabetes patients. However, from a modeling perspective, before the benefits of such a strategy can be attained, we must first be able to quantitatively characterize the behavior of the model coefficients as well as the model predictions as a function of prediction horizon. We need to determine if the model coefficients reflect viable physiologic dependencies of the individual glycemic measurements and whether the model is stable with respect to small changes in noise levels, leading to accurate near-future predictions with negligible time lag. We assessed the behavior of linear autoregressive data-driven models developed under three possible modeling scenarios, using continuous glucose measurements of nine subjects collected on a minute-by-minute basis for approximately 5 days. Simulation results indicated that stable and accurate models for near-future glycemic predictions (<60 min) with clinically acceptable time lags are attained only when the raw glucose measurements are smoothed and the model coefficients are regularized. This study provides a starting point for further needed investigations before real-time deployment can be considered.

[1]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[2]  R. Swank,et al.  Circadian Periodicity in Some Physicochemical Parameters of Circulating Blood , 1965, Nature.

[3]  D. Gough,et al.  Is blood glucose predictable from previous values? A solicitation for data. , 1999, Diabetes.

[4]  Efstratios N. Pistikopoulos,et al.  Model-based blood glucose control for type 1 diabetes via parametric programming , 2006, IEEE Transactions on Biomedical Engineering.

[5]  Claudio Cobelli,et al.  Models of subcutaneous insulin kinetics. A critical review , 2000, Comput. Methods Programs Biomed..

[6]  Giovanni Sparacino,et al.  Glucose Concentration can be Predicted Ahead in Time From Continuous Glucose Monitoring Sensor Time-Series , 2007, IEEE Transactions on Biomedical Engineering.

[7]  D. Klonoff Continuous glucose monitoring: roadmap for 21st century diabetes therapy. , 2005, Diabetes care.

[8]  B. Silverman,et al.  Functional Data Analysis , 1997 .

[9]  William L Clarke,et al.  Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application. , 2005, Diabetes technology & therapeutics.

[10]  Srinivasan Rajaraman,et al.  Predictive Monitoring for Improved Management of Glucose Levels , 2007, Journal of diabetes science and technology.

[11]  A Boutayeb,et al.  A critical review of mathematical models and data used in diabetology , 2006, Biomedical engineering online.

[12]  P Wach,et al.  Simulation studies on neural predictive control of glucose using the subcutaneous route. , 1998, Computer methods and programs in biomedicine.

[13]  P. A. Blight The Analysis of Time Series: An Introduction , 1991 .

[14]  Srinivasan Rajaraman,et al.  Individualized performance prediction of sleep-deprived individuals with the two-process model. , 2008, Journal of applied physiology.

[15]  P. Hansen Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion , 1987 .

[16]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[17]  Yang Kuang,et al.  Mathematical models and software tools for the glucose-insulin regulatory system and diabetes: an overview , 2006 .

[18]  Roger T. Bonnecaze,et al.  Inference of Blood Glucose Concentrations from Subcutaneous Glucose Concentrations: Applications to Glucose Biosensors , 1999, Annals of Biomedical Engineering.

[19]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .

[20]  Giovanni Sparacino,et al.  Glucose Prediction Algorithms from Continuous Monitoring Data: Assessment of Accuracy via Continuous Glucose Error-Grid Analysis , 2007, Journal of diabetes science and technology.