Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring

Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE) was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 μm and a base diameter of 200 μm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C) and forearm temperature (35.3 °C) are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals.

[1]  Mark R. Prausnitz,et al.  Effect of Microneedle Design on Pain in Human Volunteers , 2008, The Clinical journal of pain.

[2]  Wijaya Martanto,et al.  Transdermal Delivery of Insulin Using Microneedles in Vivo , 2004, Pharmaceutical Research.

[3]  Wei Zhou,et al.  Fabrication and impedance measurement of novel metal dry bioelectrode , 2013 .

[4]  Guojun Ma,et al.  Microneedle, bio‐microneedle and bio‐inspired microneedle: A review , 2017, Journal of controlled release : official journal of the Controlled Release Society.

[5]  Sam Emaminejad,et al.  Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis , 2016, Nature.

[6]  Conor O'Mahony,et al.  Microneedle-Based Electrodes with Integrated Through-Silicon via for Biopotential Recording , 2011 .

[7]  Yi Li,et al.  Microneedle Electrode Array for Electrical Impedance Myography to Characterize Neurogenic Myopathy , 2015, Annals of Biomedical Engineering.

[8]  Lewis R. Baxter,et al.  Electroconvulsive therapy increases circadian amplitude and lowers core body temperature in depressed subjects , 1997, Biological Psychiatry.

[9]  A. Caneschi,et al.  Temperature and pH sensors based on graphenic materials. , 2017, Biosensors & bioelectronics.

[10]  Conor O'Mahony,et al.  Preliminary technological assessment of microneedles-based dry electrodes for biopotential monitoring in clinical examinations , 2012 .

[11]  S. Campbell,et al.  Nighttime drop in body temperature: a physiological trigger for sleep onset? , 1997, Sleep.

[12]  Dirk Werschmoeller,et al.  Measurement of tool internal temperatures in the tool–chip contact region by embedded micro thin film thermocouples , 2011 .

[13]  Jung-Hwan Park,et al.  Considerations in the use of microneedles: pain, convenience, anxiety and safety , 2017, Journal of drug targeting.

[14]  Ryan F. Donnelly,et al.  Hydrogel-Forming Microneedle Arrays Can Be Effectively Inserted in Skin by Self-Application: A Pilot Study Centred on Pharmacist Intervention and a Patient Information Leaflet , 2014, Pharmaceutical Research.

[15]  Chris Yuan,et al.  In-situ temperature measurement in lithium ion battery by transferable flexible thin film thermocouples , 2014 .

[16]  F. Geiser,et al.  Metabolic rate and body temperature reduction during hibernation and daily torpor. , 2004, Annual review of physiology.

[17]  Kazuhiro Nakamura,et al.  Central circuitries for body temperature regulation and fever. , 2011, American journal of physiology. Regulatory, integrative and comparative physiology.

[18]  G. Konstantinidis,et al.  SU-8 microneedles based dry electrodes for Electroencephalogram , 2016 .

[19]  Wan Kyun Chung,et al.  Curved Microneedle Array-Based sEMG Electrode for Robust Long-Term Measurements and High Selectivity , 2015, Sensors.

[20]  Xin Dong Guo,et al.  A solid polymer microneedle patch pretreatment enhances the permeation of drug molecules into the skin , 2017 .

[21]  Xiaoming Jiang,et al.  A microneedle electrode array on flexible substrate for long-term EEG monitoring , 2017 .

[22]  Xuetao Shi,et al.  Performance Evaluation of Five Types of Ag/AgCl Bio-Electrodes for Cerebral Electrical Impedance Tomography , 2011, Annals of Biomedical Engineering.

[23]  Hiroki Ota,et al.  3D Printed "Earable" Smart Devices for Real-Time Detection of Core Body Temperature. , 2017, ACS sensors.

[24]  Roberto Merletti,et al.  The electrode-skin interface and optimal detection of bioelectric signals. , 2010, Physiological measurement.

[25]  Daniel P. Redmond,et al.  Core body temperature is normal in chronic fatigue syndrome , 1998, Biological Psychiatry.

[26]  Qing Jiang,et al.  Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring , 2016, Sensors.

[27]  Tae-Ho Hwang,et al.  Design and Fabrication of Smart Band Module for Measurement of Temperature and GSR (Galvanic Skin Response) from Human Body , 2016 .

[28]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[29]  Chong H. Ahn,et al.  A tapered hollow metallic microneedle array using backside exposure of SU-8 , 2004 .

[30]  Xingzhao Liu,et al.  Fabrication and calibration of Pt–10%Rh/Pt thin film thermocouples , 2014 .

[31]  Wei Zhou,et al.  Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method , 2016, Sensors.

[32]  Pietro Salvo,et al.  A 3D printed dry electrode for ECG/EEG recording , 2012 .