Phase‐field dithering for active catheter tracking

A strategy to increase the robustness of active MR tracking of microcoils in low signal‐to‐noise ratio conditions was developed and tested. The method employs dephasing magnetic field gradient pulses that are applied orthogonal to the frequency‐encoding gradient pulse used in conventional point‐source MR tracking. In subsequent acquisitions, the orthogonal dephasing gradient pulse is rotated while maintaining a perpendicular orientation with respect to the frequency‐encoding gradient. The effect of the dephasing gradient is to apply a spatially dependent phase shift in directions perpendicular to the frequency‐encoding gradient. Since the desired MR signal for robust MR tracking comes from the small volume of nuclear spins near the small detection coil, the desired signal is not dramatically altered by the dephasing gradient. Undesired MR signals arising from larger volumes (e.g., due to coupling with the body coil or surface coils), on the other hand, are dephased and reduced in signal intensity. Since the approach requires no a priori knowledge of the microcoil orientation with respect to the main magnetic field, data from several orthogonal dephasing gradients are acquired and analyzed in real time. One of several selection algorithms is employed to identify the “best” data for use in the coil localization algorithm. This approach was tested in flow phantoms and animal models, with several multiplexing schemes, including the Hadamard and zero‐phase reference approaches. It was found to provide improved MR tracking of untuned microcoils. It also dramatically improved MR tracking robustness in low signal‐to‐noise‐ratio conditions and permitted tracking of microcoils that were inductively coupled to the body coil. Magn Reson Med 63:1398–1403, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Charles L Dumoulin,et al.  Real-time magnetic resonance imaging for interventional neuroradiological procedures. , 2003, Surgical technology international.

[2]  Simon Wildermuth,et al.  MR-guided percutaneous angioplasty: Assessment of tracking safety, catheter handling and functionality , 2009, CardioVascular and Interventional Radiology.

[3]  M. Gado,et al.  Projection angiograms of blood labeled by adiabatic fast passage , 1986, Magnetic resonance in medicine.

[4]  Eugen Hofmann,et al.  Visualization of vascular guidewires using MR tracking , 1998, Journal of magnetic resonance imaging : JMRI.

[5]  C L Dumoulin,et al.  MR imaging-guided intravascular procedures: initial demonstration in a pig model. , 1997, Radiology.

[6]  Charles L Dumoulin,et al.  Transfemoral catheterization of carotid arteries with real-time MR imaging guidance in pigs. , 2005, Radiology.

[7]  William J Zwiebel MR angiography. , 2003, Seminars in ultrasound, CT, and MR.

[8]  M. L. Lauzon,et al.  Passive catheter visualization in magnetic resonance–guided endovascular therapy using multicycle projection dephasers , 2006, Journal of magnetic resonance imaging : JMRI.

[9]  C L Dumoulin,et al.  Joint motion in an open MR unit using MR tracking , 1999, Journal of magnetic resonance imaging : JMRI.

[10]  Maggie Fung,et al.  Electroanatomic Mapping of the Left Ventricle in a Porcine Model of Chronic Myocardial Infarction With Magnetic Resonance–Based Catheter Tracking , 2008, Circulation.

[11]  C. Dumoulin,et al.  Magnetic resonance angiography. , 1986, Radiology.

[12]  Charles L Dumoulin,et al.  Feasibility of stent placement in carotid arteries with real-time MR imaging guidance in pigs. , 2005, Radiology.

[13]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[14]  Tissue‐independent MR tracking of invasive devices with an internal signal source , 1998, Magnetic resonance in medicine.

[15]  C L Dumoulin,et al.  Glenohumeral relationships during physiologic shoulder motion and stress testing: initial experience with open MR imaging and active imaging-plane registration. , 1999, Radiology.