The Direct Detection Effect in the Hot-Electron Bolometer Mixer Sensitivity Calibration

We investigate an error in the noise temperature measurements of the hot-electron bolometer mixers caused by the so-called "direct detection effect". The effect originates in the changing of the mixer parameters when the mixer is loaded on calibration black body sources at different temperatures (300 and 77 K). A correction factor was obtained from the mixer output power versus the bias current dependence, measured by: 1) the local oscillator (LO) power tuning: 2) mixer heating: and 3) application of an external RF source. Furthermore, the direct detection effect was assessed by elimination of the heterodyne response using a LO frequency, which is far off the mixer RF band. We show that the direct detection effect can be mitigated by using an isolator between the mixer and the IF amplifier

[1]  G. Gol'tsman,et al.  Quasioptical Phonon-Cooled NbN Hot-Electron Bolometer Mixers at 0.5-1.1 THz , 1998 .

[2]  Michael Olberg,et al.  Heterodyne single-pixel facility instrumentation for the APEX Telescope , 2006, SPIE Astronomical Telescopes + Instrumentation.

[3]  D. Schaubert,et al.  Dipole and slot elements and arrays on semi-infinite substrates , 1985 .

[4]  Boris Voronov,et al.  Local Oscillator Power Requirement and Saturation Effects in NbN HEB Mixers , 2001 .

[5]  V. P. Koshelets,et al.  Superconducting integrated receiver development for TELIS , 2005, SPIE Remote Sensing.

[6]  Pourya Khosropanah,et al.  1.6 THz heterodyne receiver for the far infrared space telescope , 2002 .

[7]  Andrey M. Baryshev,et al.  Direct detection effect in small volume hot electron bolometer mixers , 2005 .

[8]  Pourya Khosropanah,et al.  Broadband Fourier Transform Spectrometer (FTS) Measurements of Spiral and Double-Slot Planar Antennas at THz Frequencies , 2002 .

[9]  Richard Lai,et al.  Terahertz frequency receiver instrumentation for Herschel's heterodyne instrument for far infrared (HIFI) , 2003, SPIE Astronomical Telescopes + Instrumentation.

[10]  Gabriel M. Rebeiz Millimeter-wave and terahertz integrated circuit antennas , 1992, Proc. IEEE.

[11]  Raymond Blundell,et al.  Study of the IF bandwidth of NbN HEB mixers based on crystalline quartz substrate with an MgO buffer layer , 2003 .

[12]  Erik L. Kollberg,et al.  Conversion gain and fluctuation noise of phonon-cooled hot-electron bolometers in hot-spot regime , 2000 .

[13]  Jonas Zmuidzinas,et al.  Superconducting detectors and mixers for millimeter and submillimeter astrophysics , 2004, Proceedings of the IEEE.

[14]  C. Vanneste,et al.  Response of superconducting films to a periodic optical irradiation , 1983 .