Investigation of magnesium fluoride crystals for imaging acousto-optic tunable filter applications.

Results of an investigation of acousto-optic (AO) cells using single crystals of magnesium fluoride (MgF2) are presented. Two acousto-optic tunable filter (AOTF) cells for imaging application have been designed and tested in the visible and ultraviolet (UV) regions of the spectrum from 190 to 490 nm. The two imaging filters were developed by using the wide-angle AO interaction geometry in the (010) and (11 0) planes of the crystal. These filters were used to obtain spectral images at the shortest wavelengths achieved so far. Advantages and drawbacks of this crystal are discussed and photoelastic, acoustic, and AO properties of MgF2 are examined. The investigation confirmed that MgF2-based AOTF cells can be used in the deep UV region up to 110 nm.

[1]  Jon W. Carnahan,et al.  Ultraviolet Quartz Acousto-Optic Tunable Filter Wavelength Selection for Inductively Coupled Plasma Atomic Emission Spectrometry , 2001 .

[2]  Vitaly B. Voloshinov Imaging experiments based on application of noncollinear tunable acousto-optic filters , 1999, Other Conferences.

[3]  D. Glenar,et al.  Acousto-optic imaging spectropolarimetry for remote sensing. , 1994, Applied optics.

[4]  I. C. Chang,et al.  Tunable Acousto-Optic Filters: An Overview , 1976, Optics & Photonics.

[5]  Harold R. Suiter,et al.  Target detection using an acousto-optic tunable filter hyperspectral imager , 1994, Defense, Security, and Sensing.

[6]  Neelam Gupta,et al.  Hyperspectral imager, from ultraviolet to visible, with a KDP acousto-optic tunable filter. , 2004, Applied optics.

[7]  J. Smith,et al.  Single‐crystal elastic constants of MgF2 in the temperature range 4.2–300 K , 1981 .

[8]  I. C. Chang,et al.  Noncollinear Acousto-Optic Filter For The Ultraviolet , 1980, Optics & Photonics.

[9]  Neelam Gupta,et al.  Ultraviolet-visible imaging acousto-optic tunable filters in KDP. , 2004, Applied optics.

[10]  A Duncanson,et al.  Some Properties of Magnesium Fluoride crystallized from the Melt , 1958 .

[11]  Pierre Laporte,et al.  Vacuum-ultraviolet refractive index of LiF and MgF 2 in the temperature range 80–300 K , 1983 .

[12]  Neelam Gupta,et al.  Hyperspectral imaging performance of a TeO2 acousto-optic tunable filter in the ultraviolet region. , 2005, Optics letters.

[13]  Neelam Gupta,et al.  Tunable acousto-optic filters for monitoring of atmospheric ozone , 2002, SPIE Optics East.

[14]  Neelam Gupta,et al.  Tunable ultraviolet hyperspectral imagers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[15]  I. C. Chang,et al.  High performance AOTFs for the ultraviolet , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).

[16]  Adrian Korpel,et al.  Acousto-optics , 1988 .

[17]  R R Alfano,et al.  Ultraviolet-visible acousto-optic tunable spectroscopic imager for medical diagnosis. , 1998, Journal of biomedical optics.