Digital Processing Of Conventional Tomograms

Conventional x-ray tomograms are limited by the presence of defocussed contributions from over and underlying structures in the final image. Edges are relatively indistinct and image contrast low when compared to conventional radiographs of the same object. Assuming that the x-ray tomograph is linear and spatially invariant with a circularly symmetric blurring function, it is possible to compensate for the presence of defocus blur to a large extent. Conventional x-ray tomograms of a composite phantom (Littleton) were used to determine the system characteristics. Circularly and quadrilaterally symmetric blurring functions computed from the phantom images were used to calculate the blurred contribution of over and underlying structures. Processed images were obtained by subtracting the defocussed components of adjacent tomoplanes from the tomographic image obtained at the level of interest. This processing was performed using a PDP-11 minicomputer by discrete fixed point convolution operations with up to 19 by 19 operators applied to a 512 x 512 image matrix. The results demonstrate a substantial improvement in subjective image quality.

[1]  L Quiding,et al.  Reduction of linear blurring in tomography. , 1969, Radiology.

[2]  P Edholm,et al.  Elimination of Blur in Linear Tomography , 1970, Acta radiologica: diagnosis.

[3]  Kenneth R. Castleman,et al.  Reconstructing 3-D Specimens From 2-D Section Images , 1971, Other Conferences.

[4]  P Schmidlin,et al.  Iterative Separation of Sections in Tomographic Scintigrams , 1972, Nuklearmedizin.

[5]  L. Rabiner,et al.  A computer program for designing optimum FIR linear phase digital filters , 1973 .

[6]  Denis Rutovitz Quantitative Imagery in the Biomedical Sciences , 1973 .

[7]  Robert A. Kilgore,et al.  Transfer Functions For Xeroradiographs And Electronic Image Enhancement Systems , 1974, Other Conferences.

[8]  S C Orphanoudakis,et al.  Mathematical model of conventional tomography. , 1976, Medical physics.

[9]  M. J. Myers Computer processig in longitudinal isotope tomography , 1976 .

[10]  R. Schutten On the possibilities of on-line image restoration by means of a finite impulse response filter , 1977 .

[11]  R. Huesman,et al.  Emission computed tomography , 1979 .

[12]  J W Scrimger,et al.  Correction for out-of-focal-plane blurring in a simulated multiplane tomographic scanner. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  John W. Strohbehn,et al.  Image Enhancement of Conventional Transverse-Axial Tomograms , 1979, IEEE Transactions on Biomedical Engineering.

[14]  Y Nakamura,et al.  Elimination of blur in linear tomography: a simple method using the X-ray processor. , 1980, Radiology.

[15]  G. F. Vermeij,et al.  The Approximation of Image Blur Restoration Filters by Finite Impulse Responses , 1980, IEEE Transactions on Pattern Analysis and Machine Intelligence.