Influence of convergence angle of tooth preparation on the fracture resistance of Y-TZP-based all-ceramic restorations.

OBJECTIVE To investigate the influence of the convergence angle of tooth preparation on the fracture load of Y-TZP-based ceramic (YZ - Vita YZ) substructure (SB) veneered with a feldspathic porcelain (VM9 - Vita VM9). METHODS Finite element stress analysis (FEA) was performed to examine the stress distribution of the system. Eighty YZ SB were fabricated using a CAD-CAM system and divided into four groups (n=20), according to the total occlusal convergence (TOC) angle: G6 - 6° TOC; G12 - 12° TOC; G20 - 20° TOC; and G20MOD - 20° TOC with modified SB. All SB were veneered with VM9, cemented in a fiber reinforced epoxy resin die, and loaded to failure. Half of the specimens from each group (n=10) were cyclic fatigued (10(6) cycles) before testing. Failure analysis was performed to determine the fracture origin. Data were statistically analyzed using Anova and Tukey's tests (α=0.05). RESULTS The greatest mean load to fracture value was found for the G20MOD, which was predicted by the FEA. Cyclic fatigue did not significantly affect the load of fracture. Catastrophic failure originating from the internal occlusal surface of the SB was the predominant failure mode, except for G20MOD. SIGNIFICANCE The YZ-VM9 restorations resisted greater compression load than the usual physiological occlusal load, regardless of the TOC angle of preparations. Yet, the G20MOD design produced the best performance among the experimental conditions evaluated.

[1]  P. H. Dehoff,et al.  Weibull analysis and flexural strength of hot-pressed core and veneered ceramic structures. , 2003, Dental materials : official publication of the Academy of Dental Materials.

[2]  A. Wilson,et al.  The relationship between preparation convergence and retention of extracoronal retainers. , 1994, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[3]  F. Migliavacca,et al.  Mechanical behaviour of nickel-titanium rotary endodontic instruments in simulated clinical conditions: a computational study. , 2008, International endodontic journal.

[4]  J R Kelly,et al.  Clinically relevant approach to failure testing of all-ceramic restorations. , 1999, The Journal of prosthetic dentistry.

[5]  G. Sjögren,et al.  Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[6]  Albert J Feilzer,et al.  The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[7]  C J Goodacre,et al.  The effect of tooth preparation design on the breaking strength of Dicor crowns: Part 1. , 1990, The International journal of prosthodontics.

[8]  Herbert T.Shillingburg...,et al.  Fundamentals of fixed prosthodontics , 1979 .

[9]  M. Bakke,et al.  Effects of ethnicity, gender and age on clenching force and load distribution , 2001, Clinical Oral Investigations.

[10]  J. Griggs,et al.  Flexural strength and failure modes of layered ceramic structures. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[11]  S. Ochi,et al.  The taper of clinical preparations for fixed prosthodontics. , 1988, The Journal of prosthetic dentistry.

[12]  I. Denry,et al.  Stabilized zirconia as a structural ceramic: an overview. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[13]  D. J. Anderson Measurement of Stress in Mastication. II , 1956, Journal of dental research.

[14]  J. Robert Kelly,et al.  Development of a clinically validated bulk failure test for ceramic crowns. , 2010, The Journal of prosthetic dentistry.

[15]  J. Knowles,et al.  An in vitro study of the compressive load at fracture of Procera AllCeram crowns with varying thickness of veneer porcelain. , 2003, The Journal of prosthetic dentistry.

[16]  Yang-Jin Yi,et al.  Effect of occlusal contact size on interfacial stresses and failure of a bonded ceramic: FEA and monotonic loading analyses. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[17]  M. Toledano,et al.  Influence of surface treatments and resin cement selection on bonding to densely-sintered zirconium-oxide ceramic. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[18]  Juo-Song Wang,et al.  Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns. , 2002, The Journal of prosthetic dentistry.

[19]  F. M. Gardner,et al.  New guidelines for preparation taper. , 1993, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[20]  Á. Della Bona,et al.  The clinical success of all-ceramic restorations. , 2008, Journal of the American Dental Association.

[21]  Irena Sailer,et al.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. , 2007, The International journal of prosthodontics.

[22]  P A Snoek,et al.  The convergence angle of tooth preparations for complete crowns. , 1987, The Journal of prosthetic dentistry.

[23]  M. Könönen,et al.  A novel bite force recorder and maximal isometric bite force values for healthy young adults. , 1993, Scandinavian journal of dental research.

[24]  E. D. Rekow,et al.  Concerns of Hydrothermal Degradation in CAD/CAM Zirconia , 2010, Journal of dental research.

[25]  S. Rosenstiel,et al.  Assessment of convergence angles of tooth preparations for complete crowns among dental students. , 2005, Journal of dentistry.

[26]  M V Swain,et al.  Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. , 2009, Acta biomaterialia.

[27]  Ariel J Raigrodski,et al.  The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. , 2006, The Journal of prosthetic dentistry.

[28]  Daniel Edelhoff,et al.  Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system. , 2008, Dental materials journal.

[29]  D Tortopidis,et al.  The variability of bite force measurement between sessions, in different positions within the dental arch. , 1998, Journal of oral rehabilitation.

[30]  J. Knowles,et al.  Flexural strength, fatigue life, and stress-induced phase transformation study of Y-TZP dental ceramic. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[31]  J. J. Mecholsky,et al.  Characterization and surface treatment effects on topography of a glass-infiltrated alumina/zirconia-reinforced ceramic. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[32]  R. Manly,et al.  An Electronic Strain Gauge for Measuring Oral Forces , 1948 .

[33]  E. D. Rekow,et al.  Thermal/mechanical simulation and laboratory fatigue testing of an alternative yttria tetragonal zirconia polycrystal core-veneer all-ceramic layered crown design. , 2010, European journal of oral sciences.

[34]  N. Ferree,et al.  Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses? , 2007, Clinical oral implants research.

[35]  C T Smith,et al.  Effective taper criterion for the full veneer crown preparation in preclinical prosthodontics. , 1999, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[36]  D. Watts,et al.  Experimental and FE shear-bonding strength at core/veneer interfaces in bilayered ceramics. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[37]  E. D. Rekow,et al.  Factorial analysis of variables influencing stress in all-ceramic crowns. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[38]  P. Coelho,et al.  Modified Y-TZP Core Design Improves All-ceramic Crown Reliability , 2011, Journal of dental research.

[39]  John F Bowley,et al.  Axial-wall inclination angle and vertical height interactions in molar full crown preparations. , 2007, Journal of dentistry.

[40]  Alvaro Della Bona,et al.  The slippery slope: critical perspectives on in vitro research methodologies. , 2012, Dental materials : official publication of the Academy of Dental Materials.

[41]  D. Edelhoff,et al.  Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. , 2009, Quintessence international.

[42]  M. Behr,et al.  Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. , 2009, Journal of dentistry.

[43]  Scherrer Ss,et al.  The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli. , 1993 .

[44]  G. Calvert Bonding to ceramics: scientific evidences for clinical dentistry , 2010, BDJ.

[45]  J. Koak,et al.  Marginal accuracy and fracture strength of ceromer/fiber-reinforced composite crowns: effect of variations in preparation design. , 2002, The Journal of prosthetic dentistry.

[46]  J I Nicholls,et al.  Stress fatigue: basic principles and prosthodontic implications. , 1995, The International journal of prosthodontics.

[47]  S A Aquilino,et al.  Tooth preparations for complete crowns: an art form based on scientific principles. , 2001, The Journal of prosthetic dentistry.