A system to track skin dose for neuro-interventional cone-beam computed tomography (CBCT)

The skin-dose tracking system (DTS) provides a color-coded illustration of the cumulative skin-dose distribution on a closely-matching 3D graphic of the patient during fluoroscopic interventions in real-time for immediate feedback to the interventionist. The skin-dose tracking utility of DTS has been extended to include cone-beam computed tomography (CBCT) of neurointerventions. While the DTS was developed to track the entrance skin dose including backscatter, a significant part of the dose in CBCT is contributed by exit primary radiation and scatter due to the many overlapping projections during the rotational scan. The variation of backscatter inside and outside the collimated beam was measured with radiochromic film and a curve was fit to obtain a scatter spread function that could be applied in the DTS. Likewise, the exit dose distribution was measured with radiochromic film for a single projection and a correction factor was determined as a function of path length through the head. Both of these sources of skin dose are added for every projection in the CBCT scan to obtain a total dose mapping over the patient graphic. Results show the backscatter to follow a sigmoidal falloff near the edge of the beam, extending outside the beam as far as 8 cm. The exit dose measured for a cylindrical CTDI phantom was nearly 10 % of the entrance peak skin dose for the central ray. The dose mapping performed by the DTS for a CBCT scan was compared to that measured with radiochromic film and a CTDI-head phantom with good agreement.

[1]  Stephen Rudin,et al.  Updates in the real-time dose tracking system (DTS) to improve the accuracy in calculating the radiation dose to the patients skin during fluoroscopic procedures , 2013, Medical Imaging.

[2]  Ming Zeng,et al.  A computer-graphic display for real-time operator feedback during interventional x-ray procedures , 2004, Medical Imaging: Image-Guided Procedures.

[3]  M. Kuo,et al.  C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. , 2009, Journal of vascular and interventional radiology : JVIR.

[4]  Sercan Akyalcin,et al.  Measurement of skin dose from cone-beam computed tomography imaging , 2013, Head & Face Medicine.

[5]  Slobodan Devic,et al.  Radiochromic film dosimetry: past, present, and future. , 2011, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[6]  James V. Byrne,et al.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology , 2010, Neuroradiology.

[7]  D. Halazonetis Cone-beam computed tomography is not the imaging technique of choice for comprehensive orthodontic assessment. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[8]  H. Bosmans,et al.  Effective dose range for dental cone beam computed tomography scanners. , 2012, European journal of radiology.