Myofiber orientation in the weanling mouse heart.

This study provides a quantitative description at the cellular level of myofiber orientation throughout the ventricles of the mouse heart. We employed computer-based methods of three-dimensional reconstruction from 3 microns plastic-embedded serial sections. Registration marks were introduced by drilling minute holes into each plastic block. Subfields of selected sections were photographed at 20 x magnification, using a computer-controlled microscope. The 35-mm film frames were projected onto a digitizer tablet and the epi- and endocardial boundaries were digitized manually. The "heads" and "tails" of linear segments of a representative myofiber sample present in each projected image were digitized in point mode. The many x-, y-, z-coordinate tables generated by digitization were reassembled automatically, giving a numerical description of the myofiber pattern. This pattern was studied interactively on a high-performance graphics workstation. We find that the heart wall is, to a first approximation, a "sandwich," in which the myofibers in the middle layer run mainly circumferentially, whereas those in the inner and outer layers run parallel or oblique to the apical-basal axis, a variant of the classical model of the myofiber pattern. We observed a "sleeve" in the interventricular septum, formed by longitudinal and oblique myofibers, a feature which apparently has not been described previously. Myofibers not running parallel to the transverse or longitudinal planes were not resolved in this study. We conclude that three-dimensional reconstruction of the cardiac myofiber pattern at the light-microscopic level, while laborious, is technically feasible and scientifically worthwhile.

[1]  S. Factor,et al.  Skeletal framework of mammalian heart muscle. Arrangement of inter- and pericellular connective tissue structures. , 1983, Laboratory investigation; a journal of technical methods and pathology.

[2]  C E THOMAS,et al.  The muscular architecture of the ventricles of hog and dog hearts. , 1957, The American journal of anatomy.

[3]  J. S. King,et al.  A simple, rapid staining procedure for methacrylate embedded tissue sections using chromotrope 2R and methylene blue. , 1984, Stain technology.

[4]  R. P. Grant,et al.  Notes on the Muscular Architecture of the Left Ventricle , 1965, Circulation.

[5]  Robert H. Anderson,et al.  Cardiac anatomy: An integrated text and colour atlas , 1980 .

[6]  T K Borg,et al.  The collagen network of the heart. , 1979, Laboratory investigation; a journal of technical methods and pathology.

[7]  Y. Fung,et al.  Transmural Myocardial Deformation in the Canine Left Ventricle: Normal in Vivo Three‐Dimensional Finite Strains , 1985, Circulation research.

[8]  A. Horowitz,et al.  Structural Considerations in Formulating Material Laws for the Myocardium , 1991 .

[9]  W. Hort,et al.  [Research on muscle fiber dilation and the structure of the right heart chamber wall in a guinea pig]. , 1957, Virchows Archiv fur pathologische Anatomie und Physiologie und fur klinische Medizin.

[10]  P. Hunter,et al.  The analysis of cardiac function: a continuum approach. , 1988, Progress in biophysics and molecular biology.

[11]  A E Becker,et al.  Left ventricular fibre architecture in man. , 1981, British heart journal.

[12]  M. Lev,et al.  Architecture of the human ventricular myocardium; technic for study using a modification of the Mall-MacCallum method. , 1956, Laboratory investigation; a journal of technical methods and pathology.

[13]  J. Prothero,et al.  Three‐dimensional reconstruction of the myofiber pattern in the fetal and neonatal mouse heart , 1989, The Anatomical record.

[14]  J W Covell,et al.  An Official Journal of the American Heart Association The Architecture of the Heart in Systole and Diastole TECHNIQUE OF RAPID FIXATION AND ANALYSIS OF LEFT VENTRICULAR GEOMETRY , 2022 .

[15]  J W Prothero,et al.  Three-dimensional reconstruction from serial sections. IV. The reassembly problem. , 1986, Computers and biomedical research, an international journal.

[16]  J W Sundsten,et al.  Three‐dimensional reconstruction from serial sections: II. A microcomputer‐based facility for rapid data collection , 1983, The Anatomical record.

[17]  R Harris,et al.  Three-dimensional reconstruction from serial sections III. AUTOSCAN, a software package in FORTRAN for semiautomated photomicrography. , 1985, Computers and biomedical research, an international journal.