Utilizing prior information in the estimation of volume fraction distribution

For many industrial processes the bulk volume fraction of one phase such as gas or solid can be of considerable importance. For this reason it is often controlled within certain limits and therefore is known at least vaguely. Tomographic imaging of volume fraction can provide very valuable information not only on the bulk volume fraction but also on the spatial distribution of the phase of interest. Prior information on the bulk volume fraction can assist in tomographic inversion, even if this information is not precise. In this paper we propose an electrical impedance tomography approach for imaging volume fraction distribution. A vague bulk volume fraction prior is utilized in the estimation. Two-dimensional numerical examples are used to demonstrate the proposed method. Copyright © 2005 John Wiley & Sons, Ltd.

[1]  Gary Lucas,et al.  Measurement of the solids volume fraction and velocity distributions in solids–liquid flows using dual-plane electrical resistance tomography , 1999 .

[2]  A. Tarantola,et al.  Generalized Nonlinear Inverse Problems Solved Using the Least Squares Criterion (Paper 1R1855) , 1982 .

[3]  Raimund Bürger,et al.  Sedimentation and suspension flows: Historical perspective and some recent developments , 2001 .

[4]  E. Somersalo,et al.  Statistical inversion and Monte Carlo sampling methods in electrical impedance tomography , 2000 .

[5]  D. L. George,et al.  Three-phase material distribution measurements in a vertical flow using gamma-densitometry tomography and electrical-impedance tomography , 2001 .

[6]  E. Somersalo,et al.  Estimating anomalies from indirect observations , 2002 .

[7]  James A. Finch,et al.  Electrical conductivity of dispersions: A review , 1993 .

[8]  Milorad P. Dudukovic,et al.  Gas holdup in bubble columns at elevated pressure via computed tomography , 2001 .

[9]  E. Somersalo,et al.  Existence and uniqueness for electrode models for electric current computed tomography , 1992 .

[10]  Steven L. Ceccio,et al.  Validation of Electrical-Impedance Tomography for Measurements of Material Distribution in Two-Phase Flows , 2000 .

[11]  Jyeshtharaj B. Joshi,et al.  Measurement of Gas Hold-up Profiles in Stirred Tank Reactors by Gamma Ray Attenuation Technique , 2001 .

[12]  P. Miller,et al.  DRYING LIGHT-WEIGHT CONCRETE SLABS , 1986 .

[13]  E Somersalo,et al.  Statistical inversion for medical x-ray tomography with few radiographs: I. General theory. , 2003, Physics in medicine and biology.

[14]  Albert Tarantola,et al.  Monte Carlo sampling of solutions to inverse problems , 1995 .

[15]  Sylvia Richardson,et al.  Markov Chain Monte Carlo in Practice , 1997 .

[16]  D. Isaacson,et al.  Electrode models for electric current computed tomography , 1989, IEEE Transactions on Biomedical Engineering.