Numerical study of SAR for multi-component orthopaedic hip replacement system during MRI

In this study we present numerical simulations of the Specific Absorption Rate (SAR) for multi-component orthopaedic hip replacement systems. The SAR is used to evaluate the radio frequency (RF)-induced heating of the devices during magnetic resonance imaging (MRI). Because multi-component orthopaedic hip replacement systems have many combinations of components with various designs and sizes, it is computationally intensive, and almost impossible, to evaluate the SAR and the corresponding temperature rise for each possible combination and configuration. In this study, an effective searching strategy and a computational simulation model are developed to evaluate the factors associated with induced SAR in the tissue near an orthopaedic hip replacement system, and to find the “worst case” peak SAR for all possible combinations. The finite-difference time-domain (FDTD) was used to calculate the peak SAR for a typical hip replacement system inside the American Society for Testing and Materials (ASTM) phantom for both 1.5 Tesla (T) and 3T MRI systems. The results indicate that the stem and screw lengths are the most important factors influencing the peak SAR for both field strengths, 1.5T/64 MHz and 3T/128 MHz, respectively. The peak 1 gram averaged SAR reaches 216 W/kg and 103 W/kg for 64 MHz and 128 MHz, respectively. We also found that shortest stems, and the longest screws, typically induce higher peak SAR.

[1]  Terry O Woods,et al.  Standards for medical devices in MRI: Present and future , 2007, Journal of magnetic resonance imaging : JMRI.

[2]  Wen Wu,et al.  Numerical investigations of MRI RF field induced heating for external fixation devices , 2013, Biomedical engineering online.

[3]  Gregor Schaefers,et al.  A Numerical Investigation of RF Heating Effects on Implants During MRI Compared to Experimental Measurements , 2007 .

[4]  Wolfgang Kainz,et al.  Computational and experimental studies of an orthopedic implant: MRI‐related heating at 1.5‐T/64‐MHz and 3‐T/128‐MHz , 2013, Journal of magnetic resonance imaging : JMRI.

[5]  Thomas Neuberger,et al.  Experimental and numerical assessment of MRI‐induced temperature change and SAR distributions in phantoms and in vivo , 2010, Magnetic resonance in medicine.

[6]  Jianming Jin,et al.  Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head. , 1998, IEEE transactions on bio-medical engineering.

[7]  Mark S. Mirotznik,et al.  Numerical evaluation of heating of the human head due to magnetic resonance imaging , 2004, IEEE Transactions on Biomedical Engineering.

[8]  Jianming Jin Electromagnetic Analysis and Design in Magnetic Resonance Imaging , 1998 .

[9]  Wen Wu,et al.  Computational study of external fixation devices surface heating in MRI RF environment , 2012, 2012 IEEE International Symposium on Electromagnetic Compatibility.

[10]  Hiroyuki Muranaka,et al.  Evaluation of RF heating on hip joint implant in phantom during MRI examinations. , 2010, Nihon Hoshasen Gijutsu Gakkai zasshi.

[11]  Safety of orthopedic implants in magnetic resonance imaging: An experimental verification , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.