Applying support vector regression analysis on grip force level-related corticomuscular coherence

Voluntary motor performance is the result of cortical commands driving muscle actions. Corticomuscular coherence can be used to examine the functional coupling or communication between human brain and muscles. To investigate the effects of grip force level on corticomuscular coherence in an accessory muscle, this study proposed an expanded support vector regression (ESVR) algorithm to quantify the coherence between electroencephalogram (EEG) from sensorimotor cortex and surface electromyogram (EMG) from brachioradialis in upper limb. A measure called coherence proportion was introduced to compare the corticomuscular coherence in the alpha (7–15Hz), beta (15–30Hz) and gamma (30–45Hz) band at 25 % maximum grip force (MGF) and 75 % MGF. Results show that ESVR could reduce the influence of deflected signals and summarize the overall behavior of multiple coherence curves. Coherence proportion is more sensitive to grip force level than coherence area. The significantly higher corticomuscular coherence occurred in the alpha (p < 0.01) and beta band (p < 0.01) during 75 % MGF, but in the gamma band (p < 0.01) during 25 % MGF. The results suggest that sensorimotor cortex might control the activity of an accessory muscle for hand grip with increased grip intensity by changing functional corticomuscular coupling at certain frequency bands (alpha, beta and gamma bands).

[1]  Claudio Babiloni,et al.  Functional coupling between anterior prefrontal cortex (BA10) and hand muscle contraction during intentional and imitative motor acts , 2008, NeuroImage.

[2]  J. R. Rosenberg,et al.  Using electroencephalography to study functional coupling between cortical activity and electromyograms during voluntary contractions in humans , 1998, Neuroscience Letters.

[3]  G. Yue,et al.  Single-Trial EEG-EMG Coherence Analysis Reveals Muscle Fatigue-Related Progressive Alterations in Corticomuscular Coupling , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  C. Tenke,et al.  Principal components analysis of Laplacian waveforms as a generic method for identifying ERP generator patterns: II. Adequacy of low-density estimates , 2006, Clinical Neurophysiology.

[5]  A M Amjad,et al.  A framework for the analysis of mixed time series/point process data--theory and application to the study of physiological tremor, single motor unit discharges and electromyograms. , 1995, Progress in biophysics and molecular biology.

[6]  W. Wong,et al.  Study on connectivity between coherent central rhythm and electromyographic activities , 2008, Journal of neural engineering.

[7]  Hiroshi Shibasaki,et al.  Electrocorticogram–electromyogram coherence during isometric contraction of hand muscle in human , 2000, Clinical Neurophysiology.

[8]  M. Butz,et al.  Changes of cortico-muscular coherence: an early marker of healthy aging? , 2011, AGE.

[9]  Robert Oostenveld,et al.  Imaging the human motor system’s beta-band synchronization during isometric contraction , 2008, NeuroImage.

[10]  Frank Huethe,et al.  Beta-range EEG-EMG coherence with isometric compensation for increasing modulated low-level forces. , 2009, Journal of neurophysiology.

[11]  C. Adler,et al.  Abnormal corticomuscular coherence is associated with the small amplitude cortical myoclonus in Parkinson's disease , 2003, Movement disorders : official journal of the Movement Disorder Society.

[12]  Aoife Finneran,et al.  Effects of grip type and wrist posture on forearm EMG activity, endurance time and movement accuracy , 2013 .

[13]  Frank Huethe,et al.  Corticomuscular coherence reflects interindividual differences in the state of the corticomuscular network during low-level static and dynamic forces. , 2012, Cerebral cortex.

[14]  Minoru Shinohara,et al.  Corticomuscular coherence with and without additional task in the elderly. , 2012, Journal of applied physiology.

[15]  Alexei Pozdnoukhov,et al.  Multi-scale support vector algorithms for hot spot detection and modelling , 2008 .

[16]  Pavel Sovka,et al.  EEG-EMG coherence enhancement , 2006, Signal Process..

[17]  Hans Lüders,et al.  Atlas of Regional Anatomy of the Brain Using MRI: With Functional Correlations , 2000 .

[18]  Jose Luis Patino,et al.  Beta-range cortical motor spectral power and corticomuscular coherence as a mechanism for effective corticospinal interaction during steady-state motor output , 2007, NeuroImage.

[19]  Guang H. Yue,et al.  Functional corticomuscular connection during reaching is weakened following stroke , 2009, Clinical Neurophysiology.

[20]  Luis Patino,et al.  Modulation of human corticomuscular beta‐range coherence with low‐level static forces , 2007, The European journal of neuroscience.

[21]  Tatsuya Mima,et al.  Cortical-muscular coherence , 2002 .

[22]  K. Spencer,et al.  Electrophysiological Assessment of Auditory Stimulus-Specific Plasticity in Schizophrenia , 2012, Biological Psychiatry.

[23]  Suresh D. Muthukumaraswamy,et al.  Temporal dynamics of primary motor cortex gamma oscillation amplitude and piper corticomuscular coherence changes during motor control , 2011, Experimental Brain Research.

[24]  Jürgen Kayser,et al.  Principal components analysis of Laplacian waveforms as a generic method for identifying ERP generator patterns: I. Evaluation with auditory oddball tasks , 2006, Clinical Neurophysiology.

[25]  G. Yue,et al.  Weakening of functional corticomuscular coupling during muscle fatigue , 2009, Brain Research.

[26]  W. Wong,et al.  Cerebral Plasticity After Subcortical Stroke as Revealed by Cortico-Muscular Coherence , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[27]  R. C. Oldfield The assessment and analysis of handedness: the Edinburgh inventory. , 1971, Neuropsychologia.

[28]  Z. Cvetković,et al.  Modulation of corticomuscular coherence by peripheral stimuli , 2012, Experimental Brain Research.

[29]  Minoru Shinohara,et al.  Attenuation of corticomuscular coherence with additional motor or non-motor task , 2011, Clinical Neurophysiology.

[30]  Pavel Sovka,et al.  WITHDRAWN: EEG–EMG coherence enhancement , 2005 .

[31]  J. Ushiba,et al.  Between-subject variance in the magnitude of corticomuscular coherence during tonic isometric contraction of the tibialis anterior muscle in healthy young adults. , 2011, Journal of neurophysiology.

[32]  J. Ushiba,et al.  Contraction level-related modulation of corticomuscular coherence differs between the tibialis anterior and soleus muscles in humans. , 2012, Journal of applied physiology.

[33]  J. R. Rosenberg,et al.  The Fourier approach to the identification of functional coupling between neuronal spike trains. , 1989, Progress in biophysics and molecular biology.

[34]  Luis Patino,et al.  Corticospinal Beta-Range Coherence Is Highly Dependent on the Pre-stationary Motor State , 2011, The Journal of Neuroscience.