Experimental study on multiple tuned mass dampers to reduce seismic responses of a three‐storey building structure

In this study, several mass dampers were designed and fabricated to suppress the seismic responses of a ¼-scale three-storey building structure. The dynamic properties of the dampers and structure were identified from free and forced vibration tests. The building structure with or without the dampers was, respectively, tested on a shake table under the white noise excitation, the scaled 1940 El Centro earthquake and the scaled 1952 Taft earthquake. The dampers were placed on the building floors using the sequential procedure developed by the authors in previous studies. Experimental results indicated that the multiple damper system is substantially superior to a single tuned mass damper in mitigating the floor accelerations even though the multiple dampers are sub-optimal in terms of tuning frequency, damping and placement. These results validated the sequential procedure for placement of the multiple dampers. The structure was also analysed numerically based on the shake table excitation and the identified structure and damper parameters for all test cases. Numerical and experimental results are in good agreement, validating the dynamic properties identified. Copyright © 2003 John Wiley & Sons, Ltd.

[1]  Takeru Igusa,et al.  Vibration Control Using Multiple Tuned Mass Dampers , 1994 .

[2]  Robert J. McNamara,et al.  Tuned Mass Dampers for Buildings , 1977 .

[3]  Masato Abe,et al.  Tuned mass dampers for structures with closely spaced natural frequencies , 1995 .

[4]  Genda Chen,et al.  Optimization of multiple tuned mass dampers for seismic response reduction , 2000, Proceedings of the 2000 American Control Conference. ACC (IEEE Cat. No.00CH36334).

[5]  K. Xu,et al.  Dynamic characteristics of multiple substructures with closely spaced frequencies , 1992 .

[6]  Jingning Wu Seismic performance, design and placement of multiple tuned mass dampers in building applications , 2000 .

[7]  Paul H. Wirsching,et al.  Minimal structural response under random excitation using the vibration absorber , 1973 .

[8]  Ahsan Kareem,et al.  Performance of Multiple Mass Dampers Under Random Loading , 1995 .

[9]  Peter Tian Generalized optimal control of elastic and inelastic structures subjected to earthquake excitation , 1997 .

[10]  Y. Fujino,et al.  Dynamic characterization of multiple tuned mass dampers and some design formulas , 1994 .

[11]  Toshihiro Ioi,et al.  On the Dynamic Vibration Damped Absorber of the Vibration System , 1977 .

[12]  G. B. Warburton,et al.  Optimum absorber parameters for simple systems , 1980 .

[13]  A. H. Chowdhury,et al.  The Past and Future of Seismic Effectiveness of Tuned Mass Dampers , 1987 .

[14]  Rene W. Luft,et al.  OPTIMUM TUNED MASS DAMPERS FOR BUILDINGS , 1979 .